HJ 571-2010 PDF EnglishUS$145.00 · In stock · Download in 9 seconds
HJ 571-2010: Technical requirement for environmental labeling products - Wood based panels and finishing products Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
HJ 571-2010: Technical requirement for environmental labeling products - Wood based panels and finishing products---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/HJ571-2010 HJ INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA Replacing HBC 17-2003 Technical requirement for environmental labeling products - Wood based panels and finishing products Issued on: MAY 04, 2010 Implemented on: JULY 1, 2010 Issued by. Ministry of Environmental Protection of the People’s Republic of China Ministry of Environmental Protection of the People’s Republic of China Announcement 2010 No.41 In order to implement “Environmental Protection Law of the People’s Republic of China”, protect environment, and promote technology advancement, “Technical requirement for environmental labeling products - Cases and bags” and other 4 standards are hereby approved and released as national environmental protection standards. Standard names and numbers are as follows. I. Technical requirement for environmental labeling products - Cases and bags (HJ 569-2010) II. Technical requirement for environmental labeling products - Toner cartridge (HJ 570-2010) III. Technical requirement for environmental labeling products - Wood based panels and finishing products (HJ 571-2010) IV. Technical requirement for environmental labeling products - Stationery (HJ 572-2010) V. Technical requirement for environmental labeling products - Ink-jet cartridge (HJ 573-2010) Above standards shall be implemented from July 1, 2010; and published by China Environmental Science Press. The contents of standards can be found at the website of Ministry of Environmental Protection (bz.mep.gov.cn). Announcement is hereby given. May 4, 2010 Table of ContentsForeword... 4 1 Application scope... 5 2 Normative references... 5 3 Terms and definitions... 5 4 Basic requirements... 6 5 Technical contents... 6 6 Test methods... 7 Annex A... 8ForewordIn order to implement “Environmental Protection Law of the People’s Republic of China”, reduce the impact of wood based panels and finishing products on environment and human health during production and use process, and protect environment, this Standard is formulated. This Standard sets forth requirements for raw materials used in wood based panels and finishing products, banned substances during timber processing, adhesives, coatings, total volatile organic compounds (TVOC) emission rate and formaldehyde emission. This Standard revises “Technical requirement for environmental labeling products - Wood based panels and finishing products” (HBC 17—2003); the main changes are as follows. — Add the requirements for the sources of raw materials and processing; — Add the requirements for total volatile organic compounds (TVOC) in products; strengthen the requirements for formaldehyde emission; — Modify the requirements for coatings; partially allow the use of waterborne coating and solvent-based wood coatings that meet requirements. HBC 17-2003 “Technical requirement for environmental labeling products - Wood based panels and finishing products” shall be abolished, from the date of implementation of this Standard. This Standard is applicable to product certification for Chinese environmental mark. This Standard was organized and drafted by Department of Science, Technology and Standards of Ministry of Environmental Protection. Main drafters of this Standard. Environmental Development Center of Ministry of Environmental Protection, and Shenzhen Academy of Metrology & Quality Inspection. This Standard was approved by Ministry of Environmental Protection on May 4, 2010. This Standard shall be implemented from July 1, 2010. This Standard shall be interpreted by Ministry of Environmental Protection. Previous versions replaced by this Standard are as follows. — HJBZ 37-1999, HBC 17-2003.Annex A(Normative) Emission Rate Determination of Total Volatile Organic Compounds (TVOC) in Wood Based Panels and Finishing Products - Climate Chamber Test Method A.1 Scope This Annex specifies a test method of determining the emission rate of total volatile organic compounds (TVOC) in wood based panels and finishing products under specific environmental conditions of climate chamber. This Annex applies to emission rate determination of total volatile organic compounds (TVOC) in wood based panels and finishing products. A.2 Method principles Put samples with 1 m2 surface area into climate chamber of which the temperature, relative humidity, air velocity and air exchange rate are controlled under predetermined conditions. Volatile organic compounds (VOC) are emitted from samples and mixed with the air inside chamber; collect the air in chamber to determine VOC concentration in air. Calculate the total VOC to obtain TVOC emission rate of samples. A.3 Equipment and reagents A.3.1 Climate chamber A.3.1.1 Volume of climate chamber Volume of climate chamber in this Standard is 1 m3. A.3.1.2 Materials of climate chamber Climate chamber’s inner wall, pipeline and test related devices shall be made of materials with low sporadic and low absorbent materials. The inert against VOC shall be as large as possible, and shall not absorb VOC to the greatest extent. Chamber’s inner wall shall have a smooth surface; it may be effectively cleaned with water before testing. A.3.1.3 Air tightness of climate chamber To avoid intrusion of surrounding air into cabinet that results in out-of-control over air exchanger, all binding sites except the joints of door for putting test piece into and taking them out shall be sealed (door has self-tightness). Climate chamber shall operate under a slight overpressure condition. re-treatment is required if it is not used within 4 weeks. A.3.6 Injectors 10 μl liquid injector, 10 μl gas injector, 1 ml gas injector. A.3.7 Volatile organic compounds for gas chromatography calibration A.3.7.1 Standard gas. Prepare the standard gas of which the concentration of compounds to be tested is known, through determined method. It is recommended that concentration of compounds of standard gas is about 100 μg/m3. A.3.7.2 Liquid standard substance. Solvents to be tested are chromatographically pure; and are not affected by the compounds that flow out together with the compounds to be tested. A.3.7.3 Calibration mixed solution. Use liquid standard substance in A.3.7.2 to prepare; it may also purchase the certified standard mixed solution. A.3.8 Injection device for preparation of liquid standard series Conventional gas chromatography inlet. It may be used on-line or assembled separately; retain carrier gas connections at inlet; the lower end of inlet may be connected to adsorption tube. A.4 Sample-taking and pre-treatment A.4.1 Sampling Samples shall be drawn from qualified products that manufacturing enterprise produces recently. For plywood and other large-sized products, after the sample is drawn, remove 50 cm from the surrounding of products, then conduct sample-taking as the test specimen; for end-product that may be used directly, such as floor boards, it may take draw samples directly. Sampling area size is based on sample load factor; sample load factor in this Standard is 1 m2/m3.Protruded part of tenon shall be removed before treatment. For raw material products such as particle board and plywood, and decorative double-faced products that may be used directly after coating and veneering, the area is calculated based on two faces. For single decorative-faced products that may be used directly after coating and veneering, the area is calculated based on one face. For products of which the sample testing surface is composed of several pieces, such as flooring products, it shall take the sample from the middle-part of packaging bag; put the products together without adhesive; then treat it according to single decorative-faced products. During single decorative-faced sample treatment, test sample may be treated back to back; the area that is not counted in calculation may also be treated through above closing method. Drawn samples shall be wrapped in aluminum foil in accordance with the provisions in A.4.2, and placed in unprinted airtight sealed polyethylene bags, one for each bag. Flooring products can use original package. It shall not exceed 1 h from sampling to Minimum temperature of cold trap. ≤−30°C (based on cold trap type adopted) Adsorbent in cold trap. Tenax TA, 40~100 mg Transmission line temperature. 220°C Split ratio. Split ratios of sample tube to secondary cold trap AND secondary cold trap to chromatographic column are selected in accordance with gas concentration. A.5.5.2 Gas chromatographic analysis reference conditions Column temperature program shall be set for compounds of which the analysis boiling point and polarity difference are large, so as to obtain test results in the shortest time. Such as, dimethyl siloxane capillary column of which the length is 50 m, inner diameter is 0.25 mm, and tube wall is 0.32 μm shall be adopted. The column operating conditions are programmed temperature rising; initial temperature maintains at 50°C for 10 min; programmed temperature rises to 250°C at... ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of HJ 571-2010 be delivered?Answer: The full copy PDF of English version of HJ 571-2010 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of HJ 571-2010_English with my colleagues?Answer: Yes. The purchased PDF of HJ 571-2010_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- HJ 571-2010 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of HJ 571-2010?A step-by-step guide to download PDF of HJ 571-2010_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "HJ 571-2010". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |