GB/T 38979-2020 PDF EnglishUS$230.00 · In stock · Download in 9 seconds
GB/T 38979-2020: Sanitary wares - Test method for flushing noise of toilet Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 38979-2020: Sanitary wares - Test method for flushing noise of toilet---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT38979-2020GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 91.140.70 Q 31 Sanitary wares - Test method for flushing noise of toilet Issued on. JULY 21, 2020 Implemented on. JUNE 01, 2021 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 3 1 Scope... 4 2 Normative references... 4 3 Terms and definitions... 5 4 Facility conditions and measuring instruments... 5 5 Sample installation and commissioning... 6 6 Sound pressure level measurement... 7 7 Result calculation... 10 8 Uncertainty of measurement... 14 9 Test report... 19ForewordThis Standard was drafted in accordance with the rules given in GB/T 1.1-2009. This Standard was proposed by China Building Materials Federation. This Standard shall be under the jurisdiction of National Technical Committee 249 on Building and Sanitary Ceramics of Standardization Administration of China (SAC/TC 249). The drafting organizations of this Standard. Tangshan Customs Comprehensive Technical Service Center, Xianyang Research & Design Institute of Ceramics, Taizhou Product Quality and Safety Testing Research Institute, Huida Sanitary Ware Co., Ltd., Xiamen R&T Plumbing Technology Co., Ltd., Xiamen Kitchen Industry Association. The drafters of this Standard. Li Wenjie, Wang Bo, Wu Yinan, Weng Xiaowei, Zhang Yihan, Zhang Xuesong, Wang Bing, Ye Ying, Zhao Jiangwei. Sanitary wares - Test method for flushing noise of toilet1 ScopeThis Standard specifies the facility conditions and measuring instruments, sample installation and commissioning, sound pressure level measurement, result calculation, uncertainty of measurement and test report for flushing noise detection of toilets (not including toilets and smart toilets that use pressure flushing devices). This Standard applies to the flushing noise detection of toilets (not including toilets and smart toilets that use pressure flushing devices).2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. GB/T 3768-2017, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane GB/T 3785.1, Electroacoustics - Sound level meters - Part 1.Specifications GB/T 6952, Sanitary wares GB/T 15173, Electroacoustics - Sound calibrators GB/T 26730, Sanitary ware - Gravity water flushing devices and supports JC/T 764, WC seats JC/T 932, Drainage fittings for sanitary wares ISO 3744, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane3 Terms and definitionsTerms and definitions determined by GB/T 3768-2017, GB/T 6952, and the following ones are applicable to this document. 3.1 Measurement time interval It is used to determine the time of integration of the sound level meter for the A- weighted cumulative percentage sound pressure level of the flushing noise of the to-be-tested toilet sample. 3.2 Standard test operator The personnel who are required to operate the to-be-tested toilet sample to complete the flushing process.4 Facility conditions and measuring instruments4.1 Test room The test room should be a semi-anechoic room or a rigid-wall room; the background noise on the hemispherical measurement surface shall be more than 3 dB(A) lower than the average value of the A-weighted equivalent sound level LAeq of the flushing noise of the to-be-tested toilet sample. 4.2 Measuring instruments The sound level meter for measurement shall meet the requirements for Grade- 2 instrument in GB/T 3785.1; it is recommended to use a Grade-1 instrument. The sound calibrator shall meet the Grade-1 accuracy requirements in GB/T 15173.5 Sample installation and commissioning5.1 Sample quantity and specifications Take a toilet sample. 5.2 Toilet matching requirements 5.2.1 For matching products, install the to-be-tested toilet sample in accordance with the manufacturer's instructions; conduct a connection tightness test under the test static pressure of 0.14 MPa ± 0.01 MPa, to ensure that the toilet and its flushing devices have the overall tightness in good condition. 5.2.2 For non-matching products, the to-be-tested toilet sample can be equipped with a gravity flushing device that meets the requirements of rated water consumption, has an anti-siphon function and meets the requirements of GB/T 26730; the working water level of the flushing tank shall meet the needs of the normal flushing process. 5.3 Installation and orientation of the toilet sample Place the to-be-tested floor-type toilet sample or the sanitary ware support that contains the wall-mounted toilet sample on the floor of the semi-anechoic room or rigid-wall room; make the distance between the center and any wall not less than 1.5 m.6 Sound pressure level measurement6.1 Determination of size of the sound source reference body Use the to-be-tested toilet sample as the sound source reference body; put down the toilet seat; lift the cover. 6.4 Sound pressure level measurement procedures 6.4.1 In a semi-anechoic room or a rigid-wall room that meets the requirements, locate each measurement point according to the microphone position coordinates on the hemispherical measurement surface. Then, move the sound level meter to the position of each measurement point in turn; ensure that the orientation of the microphone is the same as the incident angle of the sound wave when it is calibrated and it perpendicularly points to the measuring surface. Position number 6.4.4 Before testing the flushing noise of the toilet sample, it shall meet the requirements for water consumption in GB/T 6952. 6.4.5 Under the specified test static pressure, start the flushing device and time it in the normal way (generally no more than 1 s); use the A-weighted fast-time weighting characteristic "F" of the sound level meter to respectively measure the A-weighted cumulative percentage sound pressure levels LpAi(50) and LpAi(10) of the toilet flushing noise on the hemispheric measurement surface and record them.7 Result calculation7.1 Calculation of the average value of A-weighted cumulative percentage sound pressure level 7.2 Background noise correction The background noise correction values K1A(50) and K1A(10) of the A-weighted cumulative percentage sound pressure level are calculated according to Formula (5) and Formula (6) respectively. 7.3 Test environment correction Calculate the environment correction value K2A according to Formula (7). 7.5 Calculation of the sound power level During the normal flushing cycle, the sound power levels LWA (50) and LWA (10) under the meteorological conditions of the test site are calculated according to Formula (10) and Formula (11) respectively.8 Uncertainty of measurement8.1 Combined standard uncertainty uLWA of the A-weighted sound power level measurement The uncertainty uLWA of the toilet flushing noise sound power level that is measured according to this Standard is characterized by its total standard deviation σtot; it’s calculated according to Formula (12). 8.2 Determination of σomc Under the test static pressure of 0.14 MPa ± 0.01 MPa, the same standard test operator uses the same sound level meter, and, according to the test procedures that are specified in Chapter 6, uses the point that is numbered 10 on the hemispheric measurement surface as the microphone position coordinate, 8.3 Determination of σR0 8.3.1 Reproducibility standard deviation σR0 Reproducibility standard deviation σR0 includes measurement method, repeatability of sound pressure level measurement, measurement surface area, background noise correction, test environment correction, meteorological condition correction, sound level meter performance, number of measurement points, angle difference between the noise source acoustic emission direction and the measurement surface normal, frequency spectrum shape and tuned sound and other uncertainty components; it’s calculated according to Formula (15). 8.3.7 Uncertainty caused by the meteorological condition correction The uncertainty, which is caused by the reference quantity difference that is used for sound pressure level and sound power level, and the change of sound power level with temperature and pressure, is umet = 0.3 dB; the sensitivity coefficient is cmet = 1.When the altitude of the test site is less than 1 500 m, no meteorological condition correction is required; when the altitude is greater than 1 500 m, perform the meteorological condition correction in accordance with ISO 3744. 8.3.10 Uncertainty caused by the angle difference between the sound source acoustic emission direction and the measurement surface normal In a semi-anechoic room, the uncertainty which is caused by the angle difference between the acoustic emission direction of the toilet flushing noise and the hemispherical measurement surface normal is uangle = 0.25 dB; the sensitivity coefficient is cangle = 10-0.1K2A. For a rigid-walled room, it is recommended to analyze the influence of the sound source and its directivity, measurement distance and other factors to determine the standard uncertainty reasonably.9 Test reportThe test report shall include the following. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 38979-2020 be delivered?Answer: The full copy PDF of English version of GB/T 38979-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 38979-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 38979-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 38979-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 38979-2020?A step-by-step guide to download PDF of GB/T 38979-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 38979-2020". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |