GB/T 2423.62-2018 PDF EnglishUS$810.00 · In stock · Download in 9 seconds
GB/T 2423.62-2018: Environmental testing - Part 2: Test methods - Test Fx and guidance: Multi input multi output vibration test Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsGB/T 2423.62-2018: Environmental testing - Part 2: Test methods - Test Fx and guidance: Multi input multi output vibration test---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT2423.62-2018 NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 19.040 K 04 Environmental testing - Part 2.Test methods - Test Fx and guidance. Multi input multi output vibration test Issued on. DECEMBER 28, 2018 Implemented on. JULY 01, 2019 Issued by. State Administration for Market Regulation; Standardization Administration of PRC. Table of ContentsForeword... 4 1 Scope... 5 2 Terms and definitions... 5 3 Test equipment... 6 4 Test methods and conditions... 12 5 Information requirements... 18 6 Test implementation... 20 7 Analysis of results... 34 8 Contents to be given in relevant specification... 34 9 Information to be given in the test report... 35 Appendix A (Informative) Fixture for multi-excitation vibration test... 37 Appendix B (Informative) Measurement principle for spatial motion of rigid body. 53 Appendix C (Informative) Identification of time-invariant linear multi-DOF system 57 References... 671 ScopeThis part of GB/T 2423 specifies the terms and definitions test methods, test equipment, test methods and conditions, information requirements, test implementation, results analysis requirements of multi input multi output vibration (hereinafter referred to as. MIMO). This Part applies to the determination or verification of mechanical weaknesses and/or degradation of properties of samples, after subjected to excitation by multiple exciters. This test method can also be used to verify the mechanical structural and functional integrity of samples AND to study their dynamic properties.2 Terms and definitions2.1 Multi input single output; MISO In the multi-DOF structure, multiple driving signals are input to the excitation system; AND in the single-DOF structure, the single-parameter measurement output is obtained from the fixture or sample. 2.2 Multi input multi output; MIMO In multi-DOF structures, multi-driving signals are input to the excitation system; AND in multi-DOF structures, multi-measurement outputs are obtained from fixtures or samples. 2.3 Multi exciters single axis; MESA The application of multiple exciters to provide dynamic input to the sample, in a single vector direction. 2.4 Multi-exciter multi axis; MEMA Multiple exciters are used, to provide dynamic input to the sample, when the excitation and measurement are fully described by multiple vectors. 2.5 Mechanical decoupling device A mechanical device which, in the multi-exciter vibration test, is installed between the exciter and the sample, between the fixture or the whole table, to eliminate or reduce the influence of the coupled motion of the multiple exciters.3 Test equipment3.1 General requirements The multi-excitation vibration test equipment requires that, according to the type of test and the state of the sample, select an appropriately configured test platform, a fixture to install the sample, a controller, an instrument for recording the response of the sample at the designated control and monitoring position. 3.2 Multi-excitation vibration test system 3.2.1 Exciter Determine the configuration of the exciter AND select the exciter, according to the required test type, test frequency range, low frequency displacement, test magnitude, the size and mass of the sample and fixture. 3.2.2 Test fixture The design of the fixture shall meet the requirements of the vibration standard. In practice, the design of the fixture shall also consider the frequency response and the ability to withstand the reaction force. It is necessary to consider the potential for large loads during multi-point and multi-axis tests, resulting in simultaneous occurrence of acceleration at multiple degrees of freedom. The test fixture requirements are as follows. In addition to the general test fixture design requirements, refer to Appendix A for the design of multiaxial test fixtures. 3.3 Vibration control system 3.3.1 Overview The vibration control system shall have the ability to control multiple test target spectra. The control channel and monitoring channel shall meet the test requirements. The vibration control system shall be a vibration test system, that controls the excitation of multiple exciters, which can not only control the uniaxial vibration test system of multiple exciters, but also control the vibration test system of multiple exciters and multiple axes to apply different test target spectra. The control system shall be able to realize closed-loop control; continuously revise the drive signal during the test; improve the test accuracy. The controller shall have functions such as simultaneous control and analysis, simultaneous sampling of test channels and control channels, continuous data logging. 3.3.2 Control spectrum The control of the multi-exciter vibration test system is generally achieved by controlling the matrix form (specifying the self-spectral density, phase, partial coherence, specifying the cross-spectral density). The diagonal elements of the matrix are the self-spectral density of the control signal; the off-diagonal elements are the cross-spectral density. The control system can use EITHER the pre-stored cross- spectral data OR the laboratory-obtained cross-spectral data. 3.3.3 Control location The location of the control points for multi-excitation vibration tests is usually taken at the connection part, the location of some important components, the location of the measuring point that provides field test data, the end location where restrictions need to be imposed, or the load-bearing point of the structure. If necessary, limit spectra for other locations shall be specified. In order to meet the test purpose, the control strategy in the test specification is selected, according to the obtained information. The optimal control strategy depends on the existing field vibration data, OR the vibration data to be collected that meets the requirements of the test program. The need for testing and control strategies, control points, cross-coupling information will affect field data collection requirements.4 Test methods and conditions4.1 Selection of vibration test method In general, the multi-excitation vibration test method can better distribute the excitation energy to the sample, as compared with the single excitation test method; meanwhile, it can minimize the influence of boundary conditions. 4.2 Selection of test method Multiple excitation vibration tests can use different equipment configurations, to suit many practical application processes. The test process can generally be divided into the following four types. This provides only a basic selection of test process. This list cannot cover all devices or test configurations. 4.3 Determine the test plan 4.3.1 Control definition The control strategy of vibration test depends on the vibration test data, that can be provided, to achieve the purpose of vibration test. When independent spectral density, partial coherence, phase and cross-spectral density can be provided, a multi-exciter control strategy is possible. When the partial coherence, phase, cross-spectral density cannot be provided enough, it is necessary to adopt the single axial target spectrum control strategy firstly, in the vibration test. 4.3.2 Control method The choice of test method is controlled by many factors, including the external vibration environment and product type. Control functions for multiple exciter tests include. 4.3.3 Test plan For the first test of a more complex structure or a new product, a test plan shall be prepared. The test plan generally includes. 4.4 Determine the test conditions 4.4.1 Overview Usually, the multi-excitation vibration test needs to determine the test conditions, according to the measurement data of the vibration response of the sample work site. Therefore, it is necessary to obtain sufficient field data, to describe the test conditions and working states of the multi-excitation vibration test. These data are generally time histories. If the power spectrum is required, the measured data need to be estimated by auto-power spectrum and cross-power spectrum density, to determine the test conditions. Of course, when the field data is insufficient, the multi-excitation test process may determine the test conditions, through theoretical analysis of the samples AND laboratory measurement data. For the time-domain reproduction multi-excitation test, field test data is required; the correlation, between experimental control and field data, cannot be determined without field test data. 4.6 Test tolerance 4.6.1 Normal test tolerance Unless otherwise stated in the environmental test specification, the control signal shall meet the tolerance requirements specified below. 4.6.2 Relaxation of test tolerances At specific frequencies within the specified test frequency range, the test tolerances quoted above may be difficult to achieve, when using control strategies. In this case, at the discretion of the test engineer, certain test tolerance requirements may be reduced, under the following constraints; whilst other tolerances remain unchanged. The use of the following test tolerances shall be documented in the test report.5 Information requirements5.1 Overview In order to adequately conduct and document dynamic performance tests, at least the following information needs to be provided. The schedule is designed according to the actual situation; adjustments can be made, by adding or removing some items if necessary. 5.2 Information required before testing The following information is required, in order to successfully carry out the multi-point excitation vibration test. 5.3 Information required in the test The following information shall be collected during the test. 5.4 Information required after the test The following information shall be recorded after the test.6 Test implementation6.1 Test preparation 6.1.1 Preparation before the test Before the start of the test, determine the test procedure, technical state of the sample, test magnitude, test duration, excitation method, control method of the exciter, installation layout of exciter, failure criteria, sample function (performance) requirements, measuring instrument requirements, test equipment capabilities and fixtures, etc., according to the information of relevant documents and products. It also requires. 6.1.2 Pre-test inspection All samples need to be pre-tested, in a laboratory environment, to obtain benchmark data. The pre-test detection steps are as follows. 6.2 Test procedure The following are general guidelines for MIMO vibration test procedures, which is divided into 4 categories, based on whether or not a common platform is available. Procedure 1 and procedure 2 are aimed at the public platform test system; procedure 3 and procedure 4 are aimed at the distributed vibration loading test system. The procedure can be tailored, according to the test plan, control method, relevant test information. 6.6 Interruptions 6.6.1 Overview A variety of circumstances can lead to test interruption. Common causes of test interruptions and recommended solutions are discussed below. It is recommended that the test recording device be turned on, during any interruption of the test, as long as the excitation device is energized. 6.6.2 Interruption due to failure of test equipment If the interruption is due to a failure of the test equipment, it shall analyze the failure AND determine the root cause. It is also recommended to evaluate control and response data, to ensure that no undesired transient forces are transmitted to the sample, during the failure of the test equipment. If the sample is not affected by the over-test due to the failure of the test equipment, repair the test equipment or replace the test equipment; restart the test from the interrupted position. 6.6.3 Interruption due to sample run failure If the sample fails during operation, it shall interrupt the test AND analyze the cause of the failure. Depending on the circumstances, restart the test as follows. 6.6.5 Interruption due to exceeding test tolerances Exceeding the test tolerance or a significant change in the dynamic response, may cause the test engineer to initiate a test interruption, OR an automatic interruption when the test tolerance exceeds the control strategy. In this case, check the samples, fixtures, test equipment, to find out the cause. 6.7 Test safety protection measures For most system-level tests, the samples are expensive or unique, so the safety protection measures of the test system are very important. Safety protection shall be carried out, during the test process, to avoid damage or failure of the samples, due to external abnormal conditions.7 Analysis of resultsDuring the test, the test operation data is automatically stored as required. The control software shall be able to provide the following basic signal processing functions.8 Contents to be given in relevant specificationWhen this test is used in the relevant specification, as far as applicable, the following details shall be given as far as possible, paying particular attention to the clauses with an asterisk (*), because these entries are always required. The items are as follows. a) Initial vibration response check, method 1 (sinusoidal or random excitation); b) Vibration response check using sinusoidal or random excitation, method 2 *; c) Final vibration response check, method 1 and method 2; d) Fixed point *; e) Lateral movement; f) Crest factor or drive signal clipping *; g) Vibration tolerance; h) Allowable deviation (method 2) *; i) Installation; j) Test frequency range *; k) Acceleration spectral density value *; l) Acceleration spectral density spectral type *;9 Information to be given in the test reportRecords shall be made during the test. The content shall include, for example, the time list of the test operation record with test parameters, the observation and implementation during the test, the measurement data table. The test report shall give at least the following information. a) Customer (name and address); b) Laboratory (name and address); c) Test report identification (release date, unique number); d) Test date; e) Test category; f) Test purpose (R&D test, qualification test, etc.); g) Test standard name and version number (related test procedures); h) Sample description (unique identification, drawings, photos, quantities, etc.); i) Installation method of the sample (fixture identification, drawings, photos, etc.); j) Description of the test equipment (lateral movement, etc.); k) Control and measurement systems, sensor placement locations (descriptions, drawings, photos, etc.); l) The filter used (type of filter and bandwidth); m) Measurement system's uncertainty (calibration data, date of last calibration, date of next calibration); ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 2423.62-2018 be delivered?Answer: The full copy PDF of English version of GB/T 2423.62-2018 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 2423.62-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 2423.62-2018_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 2423.62-2018 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of GB/T 2423.62-2018?A step-by-step guide to download PDF of GB/T 2423.62-2018_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 2423.62-2018". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |