GB/T 23367.1-2024 PDF EnglishUS$215.00 · In stock · Download in 9 seconds
GB/T 23367.1-2024: Methods for chemical analysis of lithium cobalt oxide - Part 1: Determination of cobalt content - EDTA titration and potentiometric titration Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 23367.1: Historical versions
Similar standardsGB/T 23367.1-2024: Methods for chemical analysis of lithium cobalt oxide - Part 1: Determination of cobalt content - EDTA titration and potentiometric titration---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT23367.1-2024 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.160 CCS H 16 GB/T 23367.1-2024 Replacing GB/T 23367.1-2009 Methods for chemical analysis of lithium cobalt oxide - Part 1: Determination of cobalt content - EDTA titration and potentiometric titration ISSUED ON: NOVEMBER 28, 2024 IMPLEMENTED ON: JUNE 01, 2025 Issued by: State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword ... 3 Introduction ... 5 1 Scope ... 6 2 Normative references ... 6 3 Terms and definitions ... 6 4 Method 1: EDTA titration ... 6 5 Method 2: potentiometric titration ... 10 6 Precision ... 13 7 Test report ... 14IntroductionLithium-ion batteries are the core of 3C consumer electronic products, and lithium cobalt oxide positive electrode materials are important raw materials for 3C lithium-ion batteries. Therefore, vigorously developing lithium cobalt oxide materials is a prerequisite for achieving high-quality development of 3C consumer electronic products. GB/T 23367.1-2009 “Methods for chemical analysis of lithium cobalt oxide - Part 1: Determination of cobalt content - EDTA titration” was issued in March 2009 and implemented in January 2010. It has been more than ten years since then. The implementation and application of this Standard has unified the determination method of cobalt content in lithium cobalt oxide, significantly reducing the communication cost and trade cost of both supply and demand sides for the determination of cobalt content in lithium cobalt oxide products. In recent years, with the iteration of lithium cobalt oxide products and the upgrading of testing technology, the determination method of cobalt content in lithium cobalt oxide products has also gradually developed from the traditional EDTA manual titration to the EDTA automatic titration and redox potentiometric titration, and more stringent requirements have been put forward for the test conditions. GB/T 23367 “Methods for chemical analysis of lithium cobalt oxide” consists of 2 parts. - Part 1: Determination of cobalt content - EDTA titration and potentiometric titration; - Part 2: Determination of lithium, nickel, manganese, magnesium, aluminium, iron, sodium, calcium and copper content - Inductively coupled plasma atomic emission spectrometry. This document is formulated based on the needs of domestic and foreign lithium cobalt oxide trade. The revision of this Standard can make the determination method of cobalt content in lithium cobalt oxide products further adapt to the current level of technological development, promote the progress of related testing technologies, provide technical guidance for related domestic industries, and promote the continuous healthy and stable development of the lithium-ion battery positive electrode material industry. It is convenient for suppliers and customers to use unified analytical methods for testing, which is conducive to reducing commercial disputes caused by differences in testing methods, and has good economic and social benefits. Methods for chemical analysis of lithium cobalt oxide - Part 1: Determination of cobalt content - EDTA titration and potentiometric titration1 ScopeThis document specifies the method for determining the cobalt content in lithium cobalt oxide. Method 1 is EDTA titration, and method 2 is potentiometric titration. This document applies to the determination of cobalt content in lithium cobalt oxide. Determination range: 56.00 % ~ 62.00 %.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 6682 Water for analytical laboratory use - Specification and test methods GB/T 8170 Rules of rounding off for numerical values & expression and judgement of limiting values GB/T 17433 Foundation terms for chemical analysis of metallurgical products3 Terms and definitionsFor the purpose of this document, the terms and definitions defined in GB/T 17433 apply.4 Method 1: EDTA titration4.1 Principle After the sample is dissolved in hydrochloric acid (or a mixed solution of nitric acid and perchloric acid), in an ammonia-ammonium chloride buffer solution, with murexide as the indicator and EDTA standard titration solution as the titrant, the cobalt content is calculated based on the volume of EDTA standard titration solution consumed. It can use EDTA manual titration or EDTA automatic titration. 4.2 Reagents or materials 4.2.1 Water, GB/T 6682, grade 3 and above. 4.2.2 Hydrochloric acid (1 + 1). 4.2.3 Nitric acid (ρ = 1.42 g/mL), analytical grade or above. 4.2.4 Perchloric acid (ρ = 1.67 g/mL), analytical grade or above. 4.2.5 Cobalt standard solution: WEIGH 1.0000 g of metallic cobalt (wCo ≥ 99.98 %) in a 400 mL beaker, ADD 30 mL of hydrochloric acid (4.2.2), COVER with a watch glass, DISSOLVE completely at low temperature, COOL to room temperature, TRANSFER to a 1000 mL volumetric flask, DILUTE to the mark with water, and MIX well. 1 mL of this solution contains 1.0 mg of cobalt. Commercially available certified cobalt standard solution can also be used. 4.2.6 Ammonia-ammonium chloride buffer solution (pH ≈ 10): WEIGH 54.5 g of ammonium chloride and dissolve in water, ADD 350 mL of ammonia, DILUTE to 1000 mL with water, and MIX well. 4.2.7 Murexide indicator: WEIGH 0.4 g of murexide, ADD 50 g of potassium sulfate, and GRIND thoroughly in a mortar. Store in a desiccator. 4.2.8 Preparation of disodium ethylenediaminetetraacetate (C10H14N2O8Na2 • 2H2O, referred to as EDTA) standard titration solution (about 0.01 mol/L). WEIGH 3.72 g of EDTA into a 400 mL beaker, ADD water to dissolve with slight heat, COOL to room temperature, TRANSFER to a 1000 mL volumetric flask, DILUTE to the mark with water, and MIX well. 4.2.9 Standardization of disodium ethylenediaminetetraacetate (C10H14N2O8Na2 • 2H2O, referred to as EDTA) standard titration solution (about 0.01 mol/L) (calibration before use): TRANSFER 15.00 mL of cobalt standard solution (4.2.5) into the titration cup, record as V1. ADD 50 mL of water and 20 mL ~ 22 mL of EDTA standard titration solution (preferably 3 mL ~ 5 mL before the end point of the reaction process), then ADD 10 mL of ammonia-ammonium chloride buffer solution (4.2.6), and finally ADD about 0.1 g of murexide indicator (4.2.7). If EDTA manual titration is selected, directly titrate with EDTA standard titration solution until the solution changes from orange-yellow to purple-red, which is the end point. If EDTA automatic titration is selected, insert the photometric electrode into the automatic potentiometric titrator, and titrate to the end point with EDTA standard titration solution under stirring according to the titration end point recognition program set by the instrument. 4.5.1 Specimen Weigh 0.10 g of sample (4.4) to an accuracy of 0.0001 g. The mass of the weighed specimen is recorded as m1. 4.5.2 Parallel test Perform two tests in parallel and take the average value. 4.5.3 Blank test Perform a blank test along with the specimen, and the volume of the EDTA standard titration solution consumed is recorded as V5. 4.5.4 Determination 4.5.4.1 PLACE the specimen (4.5.1) in a 100 mL beaker, ADD 10 mL of hydrochloric acid (4.2.2), COVER with a watch glass, and HEAT on a low-temperature electric hot plate until completely dissolved. After cooling, TRANSFER to a 100 mL volumetric flask, DILUTE to the mark with water, MIX well, and RECORD the constant volume as V6. 4.5.4.2 If the specimen cannot be dissolved by hydrochloric acid (4.2.2), take another specimen (4.5.1) and PLACE it in a 100 mL beaker, ADD a mixed solution of 3 mL nitric acid (4.2.3) and 3 mL perchloric acid (4.2.4) to dissolve, COVER with a watch glass, and HEAT on a low-temperature electric hot plate until completely dissolved. Then PLACE the solution at 120 ℃ ~ 250 ℃ and HEAT until the solution volume remains 1 mL ~ 2 mL. REMOVE and cool slightly, RINSE the watch glass and the beaker wall with water, and HEAT at low temperature to dissolve the salt until the solution is clear. After cooling, TRANSFER To a 100 mL volumetric flask, DILUTE to the mark with water, MIX well, and RECORD the constant volume as V6. 4.5.4.3 TRANSFER 25.00 mL of the test solution (4.5.4.1 or 4.5.4.2) to the titration cup, RECORD it as V7. ADD about 50 mL of water and 19 mL ~ 21 mL of EDTA standard titration solution (depending on the cobalt content of lithium cobaltate, preferably 3 mL ~ 5 mL before the end of the reaction process). After stirring, ADD an appropriate amount of ammonia-ammonium chloride buffer solution (4.2.6) to adjust the pH of the solution to be tested to ≈ 10. Finally, ADD about 0.1 g of murexide indicator (4.2.7). If EDTA manual titration is selected, titrate with EDTA standard titration solution (4.2.8) until the solution changes from orange-yellow to purple-red, which is the end point. If EDTA automatic titration is selected, insert the photometric electrode (4.3.2) into the automatic potentiometric titrator (4.3.1), and titrate to the end point with EDTA standard titration solution(4.2.8) under stirring according to the titration end point recognition program set by the instrument. 5.2.2 Hydrochloric acid (1 + 1). 5.2.3 Nitric acid (ρ = 1.42 g/mL), analytical grade and above. 5.2.4 Perchloric acid (ρ = 1.67 g/mL), analytical grade and above. 5.2.5 Cobalt standard solution: WEIGH 3.0000 g of metallic cobalt (wCo ≥ 99.98 %) into a 400 mL beaker, ADD 30 mL of hydrochloric acid (5.2.2), COVER with a watch glass, DISSOLVE completely at low temperature, COOL to room temperature, TRANSFER to a 1000 mL volumetric flask, DILUTE to the mark with water, and MIX well. 1 mL of this solution contains 3.0 mg of cobalt. Commercially available certified cobalt standard solution can also be used. 5.2.6 Ammonium chloride-ammonium citrate-ammonia mixed solution (pH ≈ 10): WEIGH 62.5 g of ammonium chloride and 50 g of ammonium citrate, DISSOLVE in water, ADD 350 mL of ammonia water, DILUTE to 1000 mL with water, and MIX well. 5.2.7 Preparation of potassium ferrocyanide (K₃[Fe(CN)₆]) standard solution (about 0.05 mol/L). WEIGH 17.4 g ~ 17.8 g of potassium ferrocyanide, DISSOLVE in water, FILTER and TRANSFER into a 1000 mL brown volumetric flask, DILUTE to the mark with water, MIX well, and STORE in a dark place. 5.2.8 Standardization of potassium ferrocyanide (K₃[Fe(CN)₆]) standard solution (about 0.05 mol/L) (calibration before use): ADD 25.00 mL of potassium ferrocyanide standard solution (5.2.7) to a 250 mL beaker, RECORD it as V9, and then ADD 80 mL of ammonium chloride-ammonium citrate-ammonia mixed solution (5.2.6), and MIX well. INSERT the electrode into the potentiometric titrator and titrate with the cobalt standard solution (5.2.5) under stirring until the potential jump, which is the end point. The volume of the cobalt standard solution consumed is recorded as V8. Calculate the titration coefficient of the potassium ferrocyanide standard solution equivalent to the cobalt standard solution according to formula (3): where: K - titration coefficient, the volume ratio of the cobalt standard solution consumed by a unit volume of potassium ferrocyanide standard solution; V8 - volume of the cobalt standard solution consumed during titration, in milliliters (mL); V9 - volume of the potassium ferrocyanide standard solution added, in milliliters (mL). Perform three parallel calibrations. The range of the volume of the cobalt standard solution consumed shall not be greater than 0.05 mL. Take the average value. Otherwise, recalibrate. The calculation result is retained to four decimal places, and the rounding off of numerical values is carried out in accordance with the provisions of GB/T 8170. 5.3 Instruments and equipment 5.3.1 Automatic potentiometric titrator with stirring device. 5.3.2 Redox electrodes matching the instrument. 5.4 Samples 5.4.1 The sample particle size shall not be greater than 100 μm. 5.4.2 Before analysis, the sample shall be dried at 110 ℃ ± 5 ℃ for 2 h and placed in a desiccator to cool to room temperature. 5.5 Test steps 5.5.1 Specimen Weigh 1.00 g of sample (5.4) to an accuracy of 0.0001 g. The mass of the weighed specimen is recorded as m2. 5.5.2 Parallel test Perform two tests in parallel and take the average value. 5.5.3 Determination 5.5.3.1 PLACE the specimen (5.5.1) in a 100 mL beaker, ADD a small amount of water to moisten it, slowly ADD 20 mL of hydrochloric acid (5.2.2), COVER with a watch glass, and HEAT at low temperature until the specimen is completely dissolved. After cooling, TRANSFER to a 250 mL volumetric flask, DILUTE to the mark with water, SHAKE well, and RECORD the constant volume as V12. 5.5.3.2 If the specimen cannot be dissolved by hydrochloric acid (5.2.2), TAKE another specimen (5.5.1) and place it in a 100 mL beaker, ADD a mixed solution of 5 mL nitric acid (5.2.3) and 5 mL perchloric acid (5.2.4) to dissolve, COVER with a watch glass, and HEAT at low temperature until the specimen is completely dissolved. Then PLACE the solution at 120 ℃ ~ 250 ℃, HEAT to drive out the acid until the solution volume is about 1 mL ~ 2 mL. REMOVE and cool slightly, RINSE the watch glass and the beaker wall with water, and HEAT at low temperature to dissolve the salts until the solution is clear. After cooling, TRANSFER to a 250 mL volumetric flask, DILUTE to the mark with water, SHAKE well, and RECORD the constant volume as V12. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 23367.1-2024 be delivered?Answer: The full copy PDF of English version of GB/T 23367.1-2024 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 23367.1-2024_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 23367.1-2024_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 23367.1-2024 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 23367.1-2024?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 23367.1-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 23367.1-2024?A step-by-step guide to download PDF of GB/T 23367.1-2024_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 23367.1-2024". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |