GB/T 22246-2025 PDF EnglishUS$215.00 · In stock · Download in 9 seconds
GB/T 22246-2025: Determination of pantothenic acid in health foods Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 22246: Historical versions
Similar standardsGB/T 22246-2025: Determination of pantothenic acid in health foods---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT22246-2025GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 67.050 CCS X 83 Replacing GB/T 22246-2008 Determination of Pantothenic Acid in Health Foods Issued on: JANUARY 24, 2025 Implemented on: AUGUST 1, 2025 Issued by. State Administration for Market Regulation; Standardization Administration of the People’s Republic of China. Table of ContentsForeword... 3 1 Scope... 4 2 Normative References... 4 3 Terms and Definitions... 4 4 Principle... 4 5 Reagents or Materials... 4 6 Instruments and Equipment... 6 7 Analytical Procedures... 6 8 Calculation and Expression of Results... 8 9 Precision... 9 10 Detection Limit and Quantification Limit... 9 Appendix A (informative) High-performance Liquid Chromatograms of Pantothenic Acid Standard Solution and Specimen... 10 Determination of Pantothenic Acid in Health Foods1 ScopeThis document describes a high-performance liquid chromatography (HPLC) for the determination of pantothenic acid in health foods. This document is applicable to the determination of pantothenic acid in health foods in dosage forms, such as tablets, hard capsules, soft capsules, granules, powders, oral liquids and jelly candies, etc.2 Normative ReferencesThe contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document. GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods3 Terms and DefinitionsThis document does not have terms or definitions that need to be defined.4 PrinciplePantothenic acid in the specimen is extracted with hot water, separated by high-performance liquid chromatography, and detected by ultraviolet light. Qualitative determination is based on retention time, and quantitative determination is based on the external standard method.5 Reagents or MaterialsUnless otherwise specified, only analytically pure reagents shall be used. 5.1 Reagents 5.1.1 Water, Grade 1 water as specified in GB/T 6682. 5.1.2 Hydrochloric acid (HCl). 5.1.3 Sodium hydroxide (NaOH). 5.1.4 Phosphoric acid (H3PO4). 100 mL volumetric flasks, add water to dilute to the scale and mix them well to obtain pantothenic acid series standard working solutions with concentrations of 1 g/mL, 2 g/mL, 4 g/mL, 8 g/mL, 16 g/mL and 32 g/mL. Prepare immediately prior to use. 5.4 Materials Filter membrane. 0.45 m, aqueous.6 Instruments and Equipment6.1 High-performance liquid chromatograph. equipped with UV detector or equivalent. 6.2 Balance. with a division value of 0.001 g and 0.1 mg. 6.3 Constant-temperature oscillating water bath. with an oscillating frequency of 100 r/min 20 r/min. 6.4 Ultrasonic cleaner. 6.5 pH meter. with an accuracy of 0.01. 6.6 High-speed centrifuge. speed not less than 8,000 r/min.7 Analytical Procedures7.1 Specimen Preparation 7.1.1 Solid specimens (hard capsules, tablets and powders, etc.). take at least 20 capsules or at least 5 g of sample (for hard capsules, remove the shells and take the contents; for tablets, crush them), finely grind (if necessary), mix well and set aside. 7.1.2 Solid specimens (jelly candies, etc.). take at least 10 capsules (for mixed specimens of different colors or flavors, evenly conduct the sampling by color or flavor) or at least 10 g of sample, cut into small pieces and set aside. 7.1.3 Semi-solid specimens (soft capsules, etc.). take at least 20 capsules or at least 5 g of sample, remove the shells, take the contents, mix well and set aside. 7.1.4 Liquid specimens (oral liquids, etc.). take 5 minimum-size packages or at least 50 mL of sample (if the sample contains carbonic acid, use ultrasound to remove carbon dioxide), mix well and set aside. 7.2 Specimen Preparation Weigh-take 1 g ~ 3 g of specimen (accurate to 0.001 g), or transfer-take 1 mL ~ 3 mL of specimen, or a volume that obtains approximately 1 mg of pantothenic acid in the specimen. Place it in a 100 mL conical flask. Add 30 mL of warm water at 40 °C ~ 50 °C; vortex or stir it, until the sample is thoroughly dissolved. Perform ultrasound for 20 minutes, and cool to room temperature. Use 0.1 mol/L hydrochloric acid solution (5.1.8), 1.0 mol/L hydrochloric acid solution (5.1.9), 0.01 mol/L sodium hydroxide solution (5.1.10) or 0.1 mol/L sodium hydroxide solution (5.1.11) to adjust the pH to 5.0.Add 5 mL of 0.5 mol/L zinc sulfate solution (5.1.12) and mix it thoroughly. Transfer to a 50 mL volumetric flask, use water to dilute to the scale, mix it thoroughly, and transfer to a centrifuge tube. At 8,000 r/min, centrifuge for 2 min. Pass the supernatant through a 0.45 m filter membrane (5.4) and prepare the filtrate for determination on the machine. NOTE. if necessary, based on the content of the components in the specimen, appropriately increase the dilution factor f to ensure that the mass concentration of pantothenic acid in the specimen is within the range of 1.0 g/mL ~ 32.0 g/mL. 7.3 Chromatographic Reference Conditions The chromatographic reference conditions are as follows. a) Chromatographic column. C18 (particle size 5 m, 250 mm 4.6 mm), or equivalent chromatographic column; b) Mobile phase. potassium dihydrogen phosphate solutionacetonitrile (5.1.14); c) Flow rate. 1 mL/min; d) Column temperature. 35 °C; e) Injection volume. 10 L or 20 L; f) Detection wavelength. 200 nm. 7.4 Standard Curve Determination Successively inject the pantothenic acid standard working solution into the high-performance liquid chromatograph and determine the peak area of each component. With the mass concentration of the corresponding standard working solution as the x-coordinate and the peak area as the y-coordinate to draw a standard curve. The high-performance liquid chromatogram of the pantothenic acid standard solution (16 g/mL) is shown in Figure A.1 in Appendix A. 7.5 Determination of Specimen Solution Inject the specimen solution into the high-performance liquid chromatograph to obtain the corresponding peak area. In accordance with the standard curve, use the external standard method to calculate the mass concentration of pantothenic acid in the specimen solution to be determined. The high-performance liquid chromatogram of pantothenic acid in the specimen (tablets) is shown in Figure A.2. Perform two tests in parallel. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 22246-2025 be delivered?Answer: The full copy PDF of English version of GB/T 22246-2025 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 22246-2025_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 22246-2025_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 22246-2025 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 22246-2025?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 22246-2025 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 22246-2025?A step-by-step guide to download PDF of GB/T 22246-2025_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 22246-2025". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |