GB/T 19702-2021 PDF EnglishUS$355.00 · In stock · Download in 9 seconds
GB/T 19702-2021: In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB/T 19702: Historical versions
Similar standardsGB/T 19702-2021: In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT19702-2021 GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.100.10 C 30 GB/T 19702-2021 / ISO 15193:2009 Replacing GB/T 19702-2005 In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures (ISO 15193:2009, IDT) ISSUED ON: MARCH 09, 2021 IMPLEMENTED ON: APRIL 01, 2022 Issued by: State Administration for Market Regulation; Standardization Administration of the PRC. Table of ContentsForeword ... 3 Introduction ... 5 1 Scope ... 6 2 Normative references ... 6 3 Terms and definitions ... 7 4 Presentation of a reference measurement procedure ... 10 4.1 Elements of a reference measurement procedure ... 10 4.2 Warning and safety precautions ... 11 4.3 Introduction ... 11 4.4 Scope ... 12 4.5 Terms, definitions, symbols and abbreviated terms ... 12 4.6 Measurement principle and method ... 13 4.7 Check list ... 13 4.8 Reagents and materials ... 14 4.9 Apparatus ... 17 4.10 Sampling and sample ... 17 4.11 Preparation of measuring system and analytical portion ... 18 4.12 Operation of measuring system ... 20 4.13 Data processing ... 20 4.14 Analytical reliability ... 22 4.15 Special cases ... 25 4.16 Validation of a reference measurement procedure ... 26 4.17 Reporting ... 26 4.18 Quality assurance ... 27 4.19 Bibliography ... 27 4.20 Dates of authorization and revision ... 27 Annex A (Informative) Reference procedures for properties other than differential and rational quantities ... 28 Bibliography ... 30ForewordThis Standard is drafted in accordance with the rules given in GB/T 1.1-2009. This Standard replaces GB/T 19702-2005 "In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Description of reference materials". Compared with GB/T 19702-2005, the main technical changes of this Standard are as follows: - In the scope, add "This Standard specifies requirements for the content of a reference measurement procedure for in vitro diagnostic medical devices and medical laboratories." and "This Standard applies to reference measurement procedures providing values of differential or rational quantities. Annex A provides information on nominal properties and ordinal quantities." (see Clause 1); - ADD the terms and definitions of "analytical sensitivity", "detection limit" and "calibrator" (see Clause 3); - CHANGE the "quality assurance" element from an optional element to a mandatory element; CHANGE the "foreword", "normative references" and "special cases" elements from mandatory elements to optional elements (see Table 1); - Delete the content of 4.2.2 in "Warning and safety precautions" (see 4.2.2 of the 2005 edition); - Modify the subclause name: Modify "4.5 Terms" to "4.5 Terms, definitions, symbols and abbreviated terms" (see 4.5; 4.5 of the 2005 edition); - Modify the subclause name: Modify "4.8 Reagents" to "4.8 Reagents and materials" (see 4.8; 4.8 of the 2005 edition); - Modify the subclause name: Modify "4.16 Verification by inter-laboratory research" to "4.16 Validation of a reference measurement procedure" (see 4.16; 4.16 of the 2005 edition); - In "4.10.2 Samples", add "Requirements for the primary sample shall be specified in terms of required sample container and/or sample handling procedure, as required to minimize changes of the measurand (e.g. loss and/or contamination)" (see 4.10.2); - ADD the content of "4.14.13 Intermediate precision standard deviation" (see 4.14.13); - Modify the title of Annex A: Modify "Reference procedures for parameters other than quantities" to "Reference procedures for properties other than differential and rational quantities" (see Annex A; Annex A of the 2005 edition). This Standard, using translation method, is identical to ISO 15193:2009 "In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures". China’s document which has a consistent correspondence with the international document normatively referenced in this Standard is as follows: - GB/T 27418-2017 Guide to the evaluation and expression of uncertainty in measurement (ISO/IEC Guide 98-3:2008, MOD). This Standard was proposed by National Medical Products Administration. This Standard shall be under the jurisdiction of National Technical Committee 136 on System of Medical Clinical Test Lab and in Vitro Diagnostic System of Standardization Administration of China (SAC/TC 136). Drafting organization of this Standard: Beijing Institute of Medical Device Testing. Main drafters of this Standard: Yang Zongbing, Kang Juan, He Xueying, Wang Huiru. The previous editions of the standard replaced by this Standard were released as follows: - GB/T 19702-2005. In vitro diagnostic medical devices - Measurement of quantities in samples of biological origin - Requirements for content and presentation of reference measurement procedures1 ScopeThis Standard specifies requirements for the content of a reference measurement procedure for in vitro diagnostic medical devices and medical laboratories. Note 1: It is intended that an experienced laboratory worker who follows a measurement procedure written in accordance with this Standard can be expected to produce measurement results with a measurement uncertainty not exceeding the stipulated interval. This Standard applies to reference measurement procedures providing values of differential or rational quantities. Annex A provides information on nominal properties and ordinal quantities. This Standard is valid for any person, body or institution involved in one of the various branches of laboratory medicine whose intention is to write a document to serve as a reference measurement procedure. Full descriptions of measurement methods are usually published in scientific literature, in which methods are described in sufficient detail that they can be used as the basis of a documented measurement procedure. Note 2: In this Standard, “international measurement standard” designates a material standard. The term “international standard” is used by WHO for reference materials.2 Normative referencesThe following documents are indispensable for the application of this document. For the dated references, only the editions with the dates indicated are applicable to this document. For the undated references, the latest edition (including all the amendments) are applicable to this document. ISO 15194 In vitro diagnostic medical devices - Measurement of quantities ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB/T 19702-2021 be delivered?Answer: The full copy PDF of English version of GB/T 19702-2021 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB/T 19702-2021_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 19702-2021_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 19702-2021 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB/T 19702-2021?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 19702-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB/T 19702-2021?A step-by-step guide to download PDF of GB/T 19702-2021_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB/T 19702-2021". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |