GB 27949-2020 PDF EnglishUS$105.00 · In stock · Download in 9 seconds
GB 27949-2020: General requirements for disinfectant of medical instruments Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid GB 27949: Historical versions
Similar standardsGB 27949-2020: General requirements for disinfectant of medical instruments---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GB27949-2020NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.080 C 50 Replacing GB/T 27949-2011 General requirements for disinfectant of medical instruments ISSUED ON: APRIL 09, 2020 IMPLEMENTED ON: NOVEMBER 01, 2020 Issued by: State Administration of Market Regulation; Standardization Administration of PRC. Table of ContentsForeword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 Raw material requirements ... 6 5 Technical requirements ... 6 6 Inspection methods ... 9 7 Method of use ... 10 8 Markings ... 11 9 Packaging, storage and transportation ... 11 General requirements for disinfectant of medical instruments1 ScopeThis standard specifies the raw material requirements, technical requirements, inspection methods, methods of use, identification, packaging, storage, transportation requirements for the chemical disinfectant for the disinfection and sterilization of medical instruments. This standard applies to disinfectants for medical items. This standard does not apply to sterilization equipment with sterilization factor generators and gas or disinfection and sterilization products that play a role after being vaporized under certain conditions.2 Normative referencesThe following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard. GB/T 191 Packaging - Pictorial marking for handling of goods GB 30689 Hygienic requirements for endoscope automatic cleaning and disinfecting machine GBZ 2 (All parts) Occupational exposure limits for harmful factors in the workplace WS 507 Technical specification for cleaning and disinfection of soft endoscope Technical specification for disinfection (2002 edition) [Ministry of Health (WFJF [2002] No.282)] Technical specification for inspection of disinfection effect of endoscope cleaning and disinfecting machine (for trial) [Ministry of Health (WFJF [2003] No.330)] Pharmacopoeia of the people's Republic of China (2015 edition, four volume) 5.5.2 Requirements for simulated field test 5.5.2.1 Sterilizer At the minimum action concentration specified in the instruction manual and the dose of 50% of the shortest action time, if there is no growth of viable bacteria [Bacillus subtilis black variant (ATCC9372) spores] on the simulated medical item to be tested, it shall determine that the simulated field sterilization test of the medical item is qualified. 5.5.2.2 High-level disinfectant At the minimum action concentration specified in the instruction manual and the dose of the shortest action time, if the killing or logarithmic value of the spores of Bacillus subtilis black variant (ATCC9372) on the simulated medical item to be tested is not less than 3.00, it shall determine that the simulated field sterilization test of the medical item is qualified. 5.5.2.3 Intermediate-level disinfectant At the minimum action concentration specified in the instruction manual and the dose of the shortest action time, if the killing or logarithmic value of the Mycobacterium (ATCC19977) on the simulated medical item to be tested is not less than 3.00, it shall determine that the simulated field sterilization test of the medical item is qualified. 5.5.2.4 Low-level disinfectant Among the Staphylococcus aureus (ATCC6538), Pseudomonas aeruginosa (ATCC15422), Candida albicans (ATCC10231), select the microorganism with the strongest resistance to the tested disinfectant as the experimental microorganism. At the minimum action concentration specified in the instruction manual and the dose of the shortest action time, if the killing or extinction log- value of the microorganisms tested on the simulated medical item shall not be less than 3.00, it shall determine that the simulated field sterilization test of the medical item is qualified. 5.6 Requirements for disinfectants used in conjunction with disinfection instruments The special purpose disinfectants used in conjunction with the relevant disinfection and sterilization devices, such as disinfectants for endoscopes, disinfectants for dialysis machine’s pipelines, etc., shall meet the requirements of corresponding disinfection and sterilization devices such as WS507, GB 30689 as well as relevant national standards. It shall verify the simulated disinfection and sterilization effects used in conjunction with related equipment. It is determined according to the relevant test methods in the "Technical specifications for disinfection" (2002 edition).7 Method of use7.1 General 7.1.1 Medical items are preferred to be handled by thermal disinfection and sterilization. 7.1.2 The method of use shall comply with the standards and specifications of various types of disinfectants. 7.1.3 Before disinfecting or sterilizing the newly launched medical items, it shall first remove the oil stains and protective films; then use detergent to wash it to remove the grease; dry it. 7.1.4 Before disinfection or sterilization of contaminated medical items after use, they shall be fully cleaned and dried; the shaft joint shall be opened during treatment to fully expose it to disinfectant. 7.1.5 The sterilant which needs to be diluted before use as well as the high and intermediate level disinfectant shall be diluted by purified water, to avoid the influence of calcium, magnesium and other impurities on the disinfection effect. 7.2 Soak disinfection 7.2.1 Immerse the medical item to be treated in the disinfectant to make it completely submerged; then cover the disinfection container to let it action for the specified time. 7.2.2 For high-critical and intermediate-critical medical items, after the completion of disinfection and sterilization and before use, it shall use sterile water to rinse it clean or use other methods to remove residual disinfectant. 7.2.3 After immersed sterilization, the medical item shall avoid secondary contamination during the process of washing, transferring, storing. Among them, high-critical medical items shall be stored aseptically after sterilization; intermediate-critical medical items shall be clean-stored after sterilization or high-level disinfection; low-critical medical items shall be clean-stored after low and intermediate-level disinfection. 7.3 Wipe disinfection 7.3.1 According to the requirements of the disinfectant’s instruction manual, after the medical item is wiped and disinfected, use appropriate methods to remove residual disinfectant as appropriate. ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of GB 27949-2020 be delivered?Answer: The full copy PDF of English version of GB 27949-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of GB 27949-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB 27949-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB 27949-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version GB 27949-2020?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB 27949-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of GB 27949-2020?A step-by-step guide to download PDF of GB 27949-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "GB 27949-2020". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |