Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 27947-2020 PDF English

US$190.00 · In stock · Download in 9 seconds
GB/T 27947-2020: Hygienic requirements for phenol disinfectant
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

GB/T 27947: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
GB/T 27947-2020190 Add to Cart Auto, 9 seconds. Hygienic requirements for phenol disinfectant Valid
GB 27947-2011559 Add to Cart 3 days [GB/T 27947-2011] Hygienic requirements for phenol disinfectant Obsolete

Similar standards

GB/T 26373   GB/T 26371   GB/T 26370   GB 27951   

GB/T 27947-2020: Hygienic requirements for phenol disinfectant

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/GBT27947-2020
GB NATIONAL STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.080 C 50 Replacing GB/T 27947-2011 Hygienic requirements for phenol disinfectant ISSUED ON: JUNE 02, 2020 IMPLEMENTED ON: DECEMBER 01, 2020 Issued by: State Administration for Market Regulation; Standardization Administration of the People's Republic of China.

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Normative references ... 5 3 Terms and definitions ... 6 4 Requirement’s for raw materials ... 6 5 Technical requirements ... 7 6 Scope of application ... 8 7 Methods for use ... 9 8 Transport, storage and packaging ... 9 9 Marking requirements ... 10 10 Inspection methods ... 10 Annex A (normative) Method for determination of phenol content in disinfectant ... 12 Annex B (normative) Test method for cresol isomer content in disinfectant ... 16 Annex C (normative) Determination of p-chloro-m-xylenol in disinfectant ... 19 Annex D (normative) Determination of 2,4,4'-trichloro-2'-hydroxydiphenyl ether in disinfectant ... 21 Hygienic requirements for phenol disinfectant

1 Scope

This Standard specifies raw materials and technical requirements, scope of application, methods for use, transport, storage and packaging, marking requirements, inspection methods for phenol disinfectant. This Standard is applicable to the disinfectant that uses phenol, cresol, xylenol, p-chloro-m-xylenol, trichlorohydroxydiphenyl ether and other phenolic compound as the main raw materials, uses appropriate surfactant as solubilizer, uses ethanol, isopropanol, water as solvent, without other bactericidal ingredients. This Standard is inapplicable to single or compound disinfectant that takes other phenolic compounds as main bactericidal ingredients.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. GB/T 191, Packaging and storage marks GB/T 2600, Coking xylenol GB 27950, Hygienic requirements for hand antiseptic agents GB 27951, Hygiene requirements for skin disinfectant GB 27952, General requirements for ordinary objects surface disinfectant GB 27954, General requirements for disinfectant of mucous membrane Pharmacopoeia of the People's Republic of China (Volume II, Volume IV, 2015) Hygienic specifications for disinfection product manufacturers (2009) [Ministry of Health (issued by Department of Legal Supervision, Ministry of Health (2009) No. 53] Ethanol and isopropanol used as disinfectants for disinfection of hands, skin and mucous membranes shall meet the requirements of Pharmacopoeia of the People's Republic of China (Volume II, 2015). 4.7 Water for production Water for production shall meet the requirements for water for production in Hygienic specifications for disinfection product manufacturers (2009). 4.8 Other raw and auxiliary materials Other raw and auxiliary materials shall meet the corresponding sanitary standards, specifications and other relevant regulations. They shall have corresponding conforming certification materials.

5 Technical requirements

5.1 Active ingredient content The active ingredient content shall meet the requirements of the label value. 5.2 pH value The pH value shall meet the requirements of product enterprise standards or quality standards. 5.3 Lead, arsenic, mercury impurity limits as well as prohibited and restricted substances For disinfectant for skin and mucous membrane disinfection, its lead, arsenic, mercury impurity limits as well as prohibited and restricted substances shall meet the requirements of GB 27950, GB 27951 and GB 27954. 5.4 Indicators of killing microorganisms 5.4.1 Microbial killing effect in laboratory Select the corresponding microorganism according to the product disinfection object. According to the use concentration and action time specified in corresponding GB 27950, GB 27951, GB 27952, GB 27954, specifications and product instructions, the killing effect of microorganisms shall meet the requirements of Table 1. Table 1 -- Requirements for killing microorganisms Test microorganism Killing or inactivate microorganism logarithm Suspension method a Carrier method b

7 Methods for use

7.1 General rules Use according to the methods for use that are marked on the product label, the instruction manual. 7.2 Disinfectant containing phenol and cresol After disinfecting and wiping the object surface and fabric, the action time shall not exceed 15min. The soaking and disinfection time shall not exceed 30min. 7.3 Disinfectant containing p-chloro-m-xylenol 7.3.1 Hygienic hand disinfection: smear or wipe disinfection; the action time shall not exceed 1min. 7.3.2 Skin disinfection: wipe disinfection; the action time shall not exceed 5min. 7.3.3 Object surface disinfection: the action time after wiping shall not exceed 15min; the soaking and disinfection time shall not exceed 30min. 7.3.4 Mucosal disinfection: wipe or rinse disinfection; the action time shall not exceed 5min. 7.4 Disinfectant containing triclosan 7.4.1 Hygienic hand disinfection: smear or wipe disinfection; the action time shall not exceed 1min. 7.4.2 Surgical hand disinfection: smear or wipe disinfection; the action time shall not exceed 5min. 7.4.3 Skin disinfection: smear or wipe disinfection; the action time shall not exceed 5min. 7.4.4 Mucosal disinfection: wipe or rinse disinfection; the action time shall not exceed 5min. 7.4.5 Object surface disinfection: after wiping or spraying, the action time shall not exceed 15min; soaking disinfection time shall not exceed 30min.

8 Transport, storage and packaging

8.1 The packaging, storage and transportation marks of the product shall meet the requirements of GB/T 191. Product loading-unloading shall be handled with

Annex A

(normative) Method for determination of phenol content in disinfectant A.1 Principle Use volumetric analysis method. KBrO3 and KBr produce Br2 in acid medium. Br2 has a substitution reaction with phenol to generate stable tribromophenol. The remaining Br2 reacts with KI to produce I2. It can be Na2S2O3 standard titrant. According to the difference between Na2S2O3 standard titrant consumed by the blank (purified water instead of the sample) and Na2S2O3 standard titrant consumed by the sample, calculate the content of phenol in disinfectant. A.2 Methods A.2.1 Preparation and calibration of sodium thiosulfate standard titration solution (0.1mol/L) A.2.1.1 Preparation Weigh 26g of sodium thiosulfate pentahydrate (or 16g of anhydrous sodium thiosulfate). Add 0.20g of anhydrous sodium carbonate. Dissolve in 1000mL of water. Slowly boil it to boil 10min. Cool it. After 2 weeks of placement, use #4 glass colander to filter. A.2.1.2 Calibration Weigh 0.18g of working reference reagent potassium dichromate that has been dried at 120°C±2°C to a constant amount. Put in an iodine measuring bottle. Dissolve in 25mL of water. Add 2g of potassium iodide and 20mL of sulfuric acid solution (20%). Shake them well. Place in a dark place for 10min. Add 150mL of water (15°C~20°C). Use the prepared sodium thiosulfate solution to titrate. Add 2mL of starch indicator solution (10g/L) when it approaches to the end point. Continue to titrate until the solution turns from blue to bright green. Do a blank test at the same time. Calculate the concentration of sodium thiosulfate standard titrant according to formula (A.1):

Annex B

(normative) Test method for cresol isomer content in disinfectant B.1 Principle Use chromatographic column to separate. Use hydrogen flame ionization detector to detect. Determine the nature according to the retention time. Quantify according to peak height or peak area. B.2 Chromatographic reference conditions and system suitability test Use 2% phosphoric acid-containing glycol polyester adipate as the stationary phase. Coating concentration is 4%~10%. Use hydrogen flame detector. Column temperature is 145°C. The temperature of the inlet and detector is 200°C. B.3 Determination of calibration factor Accurately weigh 1.3g of salicylaldehyde. Put in a 50mL volumetric flask. Add ether to dissolve and dilute to the scale. Shake well and use it as the internal standard solution. Accurately weighed 0.65g of ortho-cresol reference substance. Put in a 25mL volumetric flask. Add ether to dissolve and dilute to the scale. Shake well and use it as the reference solution. Precisely measure 5 mL of the reference solution and the internal standard solution respectively. Put in a plugged test tube. Seal and plug. Shake well. Take 1μL into the gas chromatograph. Calculate the correction factor for ortho-cresol. Multiply by 1.042. It shall be the correction factor for meta-cresol. B.4 Sample determination Precisely weigh 1.0g of this product and place it in a separating funnel. Add 0.1 mL of concentrated hydrochloric acid. Shake well. Add 3mL of water. Shake well. Precisely add 20mL of ether. Shake gently. Place still for stratification. Discard the water layer. Add 5mLof water. Shake gently. Conduct stratification. Discard the water layer. Precisely measure 5mL of ether extract and 5mL of internal standard solution in a plugged test tube. Shake well. Take 1μL into the gas chromatograph. Determine. B.5 Calculation formulas B.5.1 Calculation of o-cresol correction factor

Annex C

(normative) Determination of p-chloro-m-xylenol in disinfectant C.1 Principle P-Chloride m-xylenol has UV absorption at 280nm wavelength. It may use reversed-phase high performance liquid chromatography (HPLC) to separate. Determine the nature according to the retention time. Quantify based on the peak area. This method is suitable for determining the active content of p- chloro-m-xylenol in disinfectant. C.2 Preparation of reagents Methanol (chromatographically pure). Standard solution of p-chloro-m-xylenol: weigh 0.1g of standard p-chloro-m-xylenol; use a small amount of methanol to dissolve and dilute to 100mL; this solution contains 1g of p-chloro-m-xylenol per 1L. C.3 Chromatographic reference conditions Chromatographic column: C18 column (150mm×4.6mm, inner diameter is 5μm). Mobile phase: methanol/water (70/30); before analysis, filter through 0.45μm membrane and vacuum degas. Flow rate: 1.00mL/min. UV detection wavelength: 220nm. Column temperature: 25°C. C.4 Drawing of standard curve Use standard solution of p-chloro-m-xylenol to prepare the series solutions of which the mass concentration is respectively 0mg/L, 200 mg/L, 400 mg/L, 600 mg/L and 800mg/L. Under the set chromatographic conditions, take 5μL respectively for analysis. Take the standard series mass concentration as the abscissa X and the peak area as the ordinate Y to perform linear regression processing, so as to obtain the linear equation. C.5 Sample determination If the labeled concentration of p-chloro-m-xylenol in the disinfectant is too high, it needs to be properly diluted. Make the concentration after dilution within the linear range of the standard curve. For paste samples, it shall use the mobile phase to prepare an aqueous solution. Filter by 0.45μm membrane for use. Under the set chromatographic conditions, inject 5μL of sample solution for analysis. According to the peak area, calculate the corresponding p-chloro-m-

Annex D

(normative) Determination of 2,4,4'-trichloro-2'-hydroxydiphenyl ether in disinfectant D.1 Principle 2,4,4'-Trichloro-2'-hydroxydiphenyl ether has UV absorption at 280nm. It may use reversed-phase high performance liquid chromatography (HPLC) to separate. Determine the nature according to the retention time. Quantify based on the peak area. D.2 Preparation of reagents Methanol (chromatographically pure). 2,4,4'-Trichloro-2'-hydroxydiphenyl ether standard solution: weigh 0.1g of 2,4,4'-trichloro-2'-hydroxydiphenyl ether standard product; use a small amount of methanol to dissolve; set constant volume to 100mL; this solution contains 1g of 2,4,4'-trichloro-2'- hydroxydiphenyl ether per 1L. D.3 Chromatographic reference conditions The chromatographic reference conditions are as follows: a) Chromatographic column: C18 column (150mm×4.6mm, inner diameter is 5μm); b) Mobile phase: methanol/water (80/20); before analysis, filter through 0.45μm membrane and vacuum degas; c) Flow rate: 1.5mL/min; d) UV detection wavelength: 280nm; e) Column temperature: 25°C. D.4 Drawing of standard curve Use 2,4,4'-Trichloro-2'-hydroxydiphenyl ether standard solution to prepare the series solutions of which the mass concentration is respectively 0 mg/L, 200 mg/L, 400 mg/L, 600mg/L and 800mg/L. Under the set chromatographic conditions, take 5μL respectively for analysis. Take the standard series mass concentration as the abscissa X and the peak area as the ordinate Y to perform linear regression processing, so as to obtain ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of GB/T 27947-2020 be delivered?Answer: The full copy PDF of English version of GB/T 27947-2020 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of GB/T 27947-2020_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 27947-2020_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- GB/T 27947-2020 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version GB/T 27947-2020?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 27947-2020 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of GB/T 27947-2020?

A step-by-step guide to download PDF of GB/T 27947-2020_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "GB/T 27947-2020".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9