HOME   Cart(0)   Quotation   About-Us Policy PDFs Standard-List
www.ChineseStandard.net Database: 189760 (17 Jan 2026)
Path: Home > YY/T > Page10 > YY/T 0935-2014                   Home > Standard_List > YY/T > Page10 > YY/T 0935-2014

YY/T 0935-2014 PDF English

Standard IDContents [version]USDSTEP2[PDF] deliveryName of Chinese StandardStatus
YY/T 0935-2014English145 Add to Cart 0-9 seconds. Auto-delivery Particular specifications for CT injector Valid

Excerpted PDFs (Download full copy in 9 seconds upon purchase)

PDF Preview: YY/T 0935-2014
      

Similar standards

YY/T 0935   YY/T 0933   YY/T 0891   YY/T 0933   

YY/T 0935-2014: Particular specifications for CT injector

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YYT0935-2014
YY PHARMACEUTICAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 11.040.50 C 43 Particular specifications for CT injector [Including 2020XG1 Amendment 1] ISSUED ON: JUNE 17, 2014 IMPLEMENTED ON: JULY 1, 2015 Issued by: China Food and Drug Administration

Table of Contents

Foreword ... 3 1 Scope ... 4 2 Normative references ... 4 3 Terms and definitions ... 4 4 Composition and classification ... 6 5 Requirements ... 6 6 Test methods ... 8 2020XG1 Amendment 1 ... 11 Particular specifications for CT injector

1 Scope

This standard specifies the terms and definitions, classification and composition, requirements, and test methods of CT (X-ray computed tomography) injectors (hereinafter referred to as injectors). This standard applies to injectors. This standard does not involve accessories such as disposable syringes specially used for injectors.

2 Normative references

The following documents are essential to the application of this document. For the dated referenced documents, only the versions with the indicated dates are applicable to this document; for the undated referenced documents, only the latest version (including all the amendments) is applicable to this document. GB 9706.1-2007 Medical electrical equipment - Part 1: General requirements for safety GB 9706.15-2008 Medical electrical equipment - Part 1: General requirements for safety - 1. Collateral standard: Safety requirements for medical electrical systems GB/T 10149-1988 Terminology and symbol for medical X-ray equipment GB/T 14710-2009 Environmental requirement and test methods for medical electrical equipment YY 0076-1992 Coating classifications for metal product - Technical conditions YY 0505-2012 Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Electromagnetic Compatibility - Requirements and tests YY/T 0708-2009 Medical electrical equipment - Part 1-4: General requirements for safety - Collateral standard: Programmable electrical medical systems

3 Terms and definitions

The terms and definitions defined in GB/T 10149-1988 and the followings apply to this document. 3.1 CT contrast enhanced scan A CT scan taken after a contrast agent has been injected into a blood vessel. 3.2 CT injector A device that injects a contrast agent into the body according to the set flow rate and injection volume. 3.3 injector head It refers to the injection pushing mechanism and the interface part for installing a matching syringe. 3.4 flow rate The dose of the contrast agent injected per unit of time. Unit: milliliter per second, mL/s 3.5 maximum injection pressure The maximum pressure that the injector can achieve when injecting. Unit: megapascal, MPa 3.6 pressure limit The maximum allowable pressure set for an injector during the injection. Unit: megapascal, MPa 3.7 injection delay After receiving the starting signal, the injector starts to inject after a set delay time. 3.8 scan delay After the injector starts to inject, a trigger signal is sent out after a set delay time. 3.9 inject time The time from when the injection starts to when it stops. 3.10 fill rate The dose of the contrast agent inhaled by the injector per unit of time. The setting range of the flow rate shall not be less than 0.1 mL/s~8.0 mL/s, and the error between the measured flow rate R and the set value A shall meet the requirement: -(0.05A+0.1) ≤ R-A ≤ 0.05A+0.1. 5.3 Injection volume The setting range of the injection volume shall not be less than 1.0 mL~100 mL, and the error between the measured injection volume R and the set value A shall meet the requirement: -(0.05A+1) ≤ R-A ≤ 0.05A+1. 5.4 Fill rate If applicable, the fill rate of the injector shall be specified in the product standard. 5.5 Maximum injection pressure The maximum injection pressure that can be achieved by the injector using the syringe shall not be less than 1.72 MPa (250 psi). 5.6 Pressure limit The injector shall be able to be set the injection pressure limit, the deviation shall not exceed ±20%. 5.7 Injection delay time The setting range of the injection delay time shall be specified in the product standard, and the deviation shall not be greater than ±10%. 5.8 Scan delay time The setting range of the scan delay time shall be specified in the product standard, and the deviation shall not be greater than ±10%. 5.9 Rotation angle of the injector head If applicable, when the injector head is upward, it shall be ensured that the air in the syringe is exhausted; when the injector head is downward, the angle between it and the horizontal plane should not be less than 10°. 5.10 Functions The injector shall have the following functions: a) It can display the continued time of injection and the volume injected; b) When the injection pressure exceeds the pressure limit value, it shall be able to send a clear signal to remind the user and stop the injection; The test medium is distilled water or deionized water. The injection volume is set to 100 mL; under the conditions that the flow rate is set to the minimum value, 50% of the maximum value, and the maximum value respectively, use a timer (such as a synchronous stopwatch) to record the time from the start of the injection to the end of the injection, weigh the distilled water with a balance and convert it to volume, and then calculate the deviation of the flow rate. 6.3 Injection volume The test medium is distilled water or deionized water. The injection volume is set to the minimum value (the flow rate is at the minimum value), 50% of the maximum value (the flow rate is at 50% of the maximum value), and the maximum value (the flow rate is at the maximum value) respectively to complete the injection, weigh the distilled water or deionized water with a balance and convert it to volume, and then calculate the deviation of the injection volume. 6.4 Fill rate Verify it by actual operation. 6.5 Maximum injection pressure Set the pressure limit to the maximum value of the injector, connect the connector to the syringe and pressure gauge, and set the flow rate at 2 mL/s for bolus injection; read the pressure when the injector indicates that the pressure limit is exceeded and the bolus injection is stopped, and then calculate the deviation of the maximum injection pressure. 6.6 Pressure limit Set the pressure limit to 1.72 MPa (250 psi), connect the connector to the syringe and pressure gauge, and set the flow rate at 2 mL/s for bolus injection; read the pressure when the injector indicates that the pressure limit is exceeded and the bolus injection is stopped, and then calculate the deviation between the actual pressure and the set pressure. 6.7 Injection delay time Set the delay time to 3 s, use a timer to record the time from the receiving of the starting signal to the start of injection, and calculate the deviation of injection delay. 6.8 Scan delay time Set the delay time to 3 s, use a timer to record the time from the start of injection to the emitting of the trigger signal, and calculate the deviation of injection delay. [Translator’s note: should be scan delay] ......
Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.


      



Price & Delivery

US$145.00 · In stock · Download in 9 seconds
YY/T 0935-2014: Particular specifications for CT injector
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

Tips & Frequently Asked Questions

Question 1: How long will the true-PDF of English version of YY/T 0935-2014 be delivered?

Answer: The full copy PDF of English version of YY/T 0935-2014 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YY/T 0935-2014_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0935-2014_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. www.ChineseStandard.us -- YY/T 0935-2014 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

How to buy and download a true PDF of English version of YY/T 0935-2014?

A step-by-step guide to download PDF of YY/T 0935-2014_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YY/T 0935-2014".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9   

Refund Policy     Privacy Policy     Terms of Service     Shipping Policy     Contact Information