Search result: GB/T 31563-2015
Standard ID | Contents [version] | USD | STEP2 | [PDF] delivered in | Standard Title (Description) | Status | PDF |
GB/T 31563-2015 | English | 209 |
Add to Cart
|
3 days [Need to translate]
|
Metallic coatings -- Measurement of coating thickness -- Scanning electron microscope method
| Valid |
GB/T 31563-2015
|
Standard ID | GB/T 31563-2015 (GB/T31563-2015) | Description (Translated English) | Metallic coatings -- Measurement of coating thickness -- Scanning electron microscope method | Sector / Industry | National Standard (Recommended) | Classification of Chinese Standard | A29 | Classification of International Standard | 25.220.40 | Word Count Estimation | 10,179 | Date of Issue | 2015-05-15 | Date of Implementation | 2016-01-01 | Quoted Standard | GB/T 6462; GB/T 12334; GB/T 27788-2011 | Adopted Standard | ISO 9220-1988, MOD | Regulation (derived from) | National Standard Announcement 2015 No. 15 | Issuing agency(ies) | Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China | Summary | This Standard specifies the way through a scanning electron microscope (SEM) to detect the thickness of the metal sample cross-section of the local metal coating thickness measurement method. It is usually a destructive testing methods, uncertainty of less than 10%, or 0.1 ��m. The measuring method can also be used to measure several millimeters thick coatings, but is recommended for such thick coatings optical microscopy (GB/T 6462) were measured. |
GB/T 31563-2015
Metallic coatings. Measurement of coating thickness. Scanning electron microscope method
ICS 25.220.40
A29
National Standards of People's Republic of China
Metallic coating thickness measurement
Scanning electron microscopy
(ISO 9220. 1988, MOD)
Issued on. 2015-05-15
2016-01-01 implementation
Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China
Standardization Administration of China released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This revised standard adopts ISO 9220. 1988 "metallic coating thickness measurement scanning electron microscope."
This standard and ISO 9220. 1988 main technical differences are as follows.
--- Control ISO 9220. 1988 (9.2.1.2), this standard uses photographic imaging output. Due to technical development, the Standard is a modified meter
Computer disk record store the image and calibration. ISO standard relates to video signal waveforms present device is not used, this
Standard with a resolution higher EDS line scan technology.
--- Normative references Replace the corresponding country standards, and increases the GB/T 27788-2011 of reference.
The standard proposed by China Machinery Industry Federation.
This standard layer Standardization Technical Committee (SAC/TC57) administered by the National Metal and non-metal cover.
This standard was drafted. Wuhan Institute of Material Protection, Tsinghua University, Zhuzhou Diamond Carbide Factory, Xi'an High Voltage Switch Co.
Secretary, Chongqing Institute of Metrology and Quality Inspection, five Dongguan City Electronic Technology Co., Shenzhen City of Lancaster Precision Technology Co., Ltd.
The main drafters of this standard. Li Jian, Shaotian Min, Duan Haitao, Liu Xiusheng, Chen Li, Mabo, Tu Jie Song, Wang Ding, in Raymond, the country has the right, Sun Alliance.
Metallic coating thickness measurement
Scanning electron microscopy
1 Scope
This standard specifies the detection of metallic cross-sectional sample local thickness by a scanning electron microscope (SEM) metal coating thickness measurement mode
Methods degrees. It is usually a destructive detection methods, uncertainty of less than 10%, or 0.1μm. This measurement method can also be used
Measuring a few millimeters thick coatings, but is recommended for such thick coatings optical microscopy (GB/T 6462) were measured.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6462 and the metal oxide coating layer thickness measurement microscope method (GB/T 6462-2005, ISO 1463.2003,
IDT)
GB/T 12334 Metallic and other inorganic coatings - Definitions and general rules on thickness measurements (GB/T 12334-2001,
ISO 2064.1996, IDT)
GB/T 27788-2011 micro beam analysis SEM image magnification calibration guidelines (ISO 16700.2004, IDT)
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1
Local thickness localthickness
Within a specified area of \u200b\u200bthe coating multiple measurements, averaging the resulting thickness value.
[GB/T 12334-2001,3.4]
Principle 4
The sample coating direction perpendicular to the horizontal cutting, grinding and polishing and carefully prepare metallographic sample, placed in a scanning electron microscope
The testing. Measured by conventional coating microscopic cross section images to obtain the coating thickness.
5 Instruments
5.1 Scanning electron microscope (SEM)
Resolution should be better than 50nm.
5.2 SEM tai micrometer scale
Used to calibrate magnification scanning electron microscope, the error value of the uncertainty should be less than 5%.
......
|