Powered by Google www.ChineseStandard.net Database: 189759 (21 Apr 2024)

GB/T 24347-2009 (GBT24347-2009)

GB/T 24347-2009_English: PDF (GBT 24347-2009, GBT24347-2009)
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusPDF
GB/T 24347-2009English70 Add to Cart 0--9 seconds. Auto-delivery The DC/DC converter for electric vehicles Obsolete GB/T 24347-2009

BASIC DATA
Standard ID GB/T 24347-2009 (GB/T24347-2009)
Description (Translated English) The DC/DC converter for electric vehicles
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard T47
Classification of International Standard 43.080.01
Word Count Estimation 11,111
Date of Issue 2009-09-30
Date of Implementation 2010-02-01
Quoted Standard GB/T 2423.1; GB/T 2423.2; GB/T 2423.17; GB 4208-2008; GB 14711-2006; GB/T 17619-1998; GB/T 18384.1-2001; GB/T 18488.1-2006; GB 18655-2002; QC/T 413-2002
Drafting Organization Tsinghua University
Administrative Organization National Automotive Standardization Technical Committee
Regulation (derived from) National Standard Approval Announcement 2009 No.10 (Total No.150)
Proposing organization National Development and Reform Commission
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the electric vehicle DC/DC converter requirements, test methods, inspection rules, signs, packaging, transport, storage and so on. This standard applies to electric vehicle power supply system using DC/DC converter. Accessories and control systems Low (12V, 24V) power supply system using a DC/DC converter can refer to this standard related content. Involved in the standard DC/DC converter power rating of kilowatt (1kM-200kW), does not include modular low-power DC/DC converters.

Standards related to: GB/T 24347-2009

GB/T 24347-2009
GB/T24347-2009
GB
ICS 43.080.01
T 47
NATIONAL STANDARD
OF THE PEOPLE’S REPUBLIC OF CHINA
The DC/DC converter for electric vehicles
ISSUED ON. SEPTEMBER 30, 2009
IMPLEMENTED ON. FEBRUARY 1, 2010
Issued by. General Administration of Quality Supervision, Inspection
and Quarantine of the People’s Republic of China;
Standardization Administration of China.
Table of Contents
Foreword ... 3 
1 Scope ... 4 
2 Normative references ... 4 
3 Terms and definitions ... 5 
4 Classification and model designation ... 7 
5 Requirements ... 7 
6 Test method ... 10 
7 Inspection rules ... 14 
8 Labeling, packaging, transportation, and storage ... 16 
Foreword
This Standard was proposed by National Development and Reform Commission.
This Standard shall be under the jurisdiction of National Technical Committee on Road
Vehicles of Standardization Administration of China.
The responsible drafting organizations of this Standard. Tsinghua University, Chinese
Automotive Technology & Research Centre, Beijing University of Aeronautics and
Astronautics, and CSR’S Zhuzhou Electric Locomotive Research Institute.
The chief drafting staffs of this standard. Chen Quanshi, He Yuntang, Gao Dawei, Qi
Bojin, Shi Shuangrong, Yang Weibin, and Wu Lixun.
The DC/DC converter for electric vehicles
1 Scope
This Standard specifies the requirements, test method, inspection rules, labeling,
packaging, transportation and storage, etc. for the DC/DC converter for electric vehicles.
This Standard applies to the DC/DC converter of power supply for electric vehicles. For
the DC/DC converter used for low voltage power system (12V, 24V) of accessories and
control systems, it may reference to the relevant contents of this Standard.
The power rating of DC/DC converters involved in this Standard is KW-level (1 kW ~ 200
kW). It does not include modular low-power DC/DC converters.
2 Normative references
The articles contained in the following documents have become part of this Standard
when they are quoted herein. For the dated documents so quoted, all the modifications
(excluding corrections) or revisions made thereafter shall not be applicable to this
Standard. For the undated documents so quoted, the latest editions shall be applicable to
this Standard.
GB/T 2423.1 Environmental testing for electric and electronic products – Part 2. Test
methods – Tests A. Cold (GB/T 2423.1-2008, IEC 60068-2-1. 2007, IDT)
GB/T 2423.2 Environmental testing for electric and electronic products – Part 2. Test
methods – Tests A. Hot (GB/T 2423.2-2008, IEC 60068-2-2. 2007, IDT)
GB/T 2423.17 Environmental testing for electric and electronic products – Part 2. Test
methods – Tests Ka. Salt spray (GB/T 2423.17-2008, IEC 60068-2-1. 1981, IDT)
GB 4208-2008 Degrees of protection provided by enclosure (IP code) (IEC 60529.2001,
IDT)
GB 14711-2006 General requirements for safety of small and medium size rotating
electrical machines
GB/T 17619-1998 Limits and methods of testing for immunity of electrical / electronic
sub-assemblies in vehicles to electromagnetic radiation
The earthing point shall be clearly indicated with earthing mark.
5.9 Electrical gap and creepage distance
The electrical gap and creepage distance shall be in accordance with the relevant
requirements specified in Table 3 of GB/T 18488.1-2006.
5.10 Rated power
The maximum output power from the DC/DC converter shall be greater than or equal to
the rated power value indicated on the nameplate after the temperature rise is stable,
under specified environmental condition, rated voltage, and continuous operating
condition.
5.11 Peak output power and duration
For a DC/DC converter, the overloading output power shall not be less than 1.2 times of
its rated power. The operating duration measured at peak value according to the method
as mentioned in sub-clause 6.11 shall not be less than 6 min.
5.12 Electromagnetic compatibility (EMC)
For a DC/Dc converter, the conductive interference and radiated interference generated
during operation shall not exceed the limits specified in clauses 12 and 14 in GB 18655-
2002.
The anti-interference of an operating DC/DC converter shall comply with clause 4 of
GB/T 17619-1998.
5.13 Dynamic response time
The dynamic response time of a DC/DC converter shall meet the delivery documents
signed by the manufacturer and user.
5.14 Reliability
The mean time between failures (MTBF) of a DC/DC converter shall not be less than
3000 h, under the rated load or according to the set condition of cyclic operation.
5.15 Durability
The durability requirements of a DC/DC converter shall meet the delivery documents
signed by manufacturer and user.
For a DC/DC converter, the humidity test shall be carried out in accordance with sub-
clause 3.11 of QC/T 413-2002, for 2 cycles. During test, when 0 ~ 45°C, the DC/DC
converter shall operate at normal state.
6.1.3 Salt spray
The salt spray test shall be in accordance with the relevant requirements of GB/T
2423.17. The DC/DC shall be properly installed. The recommended test duration shall be
16 h, 24 h and 48 h. Upon completion of test, and after the DC/DC converter is recovered
for 1 h ~ 2 h, check if it can operate normally after energized.
6.2 Vibration test
A DC/DC converter shall be performed for vibration test in accordance with sub-clause
3.12 of QC/T 413-2002.
6.3 Mechanical strength of outer housing
Evenly apply a force equivalent to a weight of 100 kg onto an arbitrary area of 30 cm × 30
cm on the surface of the outer housing of the DC/DC converter. Observe the plastic
deformation on the surface.
6.4 Protection level
Test shall be carried out in accordance with GB 4208-2008 with respect to IP55.
6.5 Noise
A DC/DC converter shall be performed for operating noise in accordance with sub-clause
4.4 of QC/T 413-2002.
6.6 Insulation performance
Under the condition that the DC/DC converter is not operated, when the ambient
temperature is 23°C±2°C and relative humidity is 80% ~ 90%, use a 1000V megger (or
other instrument with the same function and precision level) to measure the insulation
resistance between the live circuit of a DC/DC converter and the earth (outer housing).
6.7 Performance of voltage withstanding
Under the condition that the DC/DC converter is not operated, when the ambient
temperature is 23°C±2°C and relative humidity is 80% ~ 90%, use a voltage withstanding
tester with a measuring range of 2000 V (DC) (or rated voltage of +1500 V) to measure
b) Certificate of conformity; and
c) Instructions for use.
8.3 Transportation
8.3.1 During transportation, the product shall be kept away from serious mechanical
impact, strong sunlight and rain, not turned upside down.
8.3.2 During loading/unloading, handle the product with care. Strictly avoid throwing,
rolling and heavy load.
8.4 Storage
8.4.1 The product may be stored in a dry, clean, and well-ventilated warehouse with a
temperature range from -30 ~ +70°C.
8.4.2 The product shall not be exposed to direct sunlight and kept away from heat source
by not less than 2 m.
8.4.3 The product shall not be turned upside down and shall avoid mechanical impact
and heavy load.
...