Powered by Google-Search & Google-Books www.ChineseStandard.net Database: 169760 (Feb 27, 2021)
HOME   Quotation   Tax   Examples Standard-List   Contact-Us   View-Cart
  

GB/T 22927-2008

Chinese Standard: 'GB/T 22927-2008'
Standard IDContents [version]USDSTEP2[PDF] delivered inStandard Title (Description)StatusRelated Standard
GB/T 22927-2008English150 Add to Cart 0--10 minutes. Auto immediate delivery. Respirator paper Valid GB/T 22927-2008
GB/T 22927-2008Chinese14 Add to Cart <=1-day [PDF from Chinese Authority, or Standard Committee, or Publishing House]

  In 0~10 minutes time, full copy of this English-PDF will be auto-immediately delivered to your email. See samples for translation quality.  

BASIC DATA
Standard ID GB/T 22927-2008 (GB/T22927-2008)
Description (Translated English) Respirator paper
Sector / Industry National Standard (Recommended)
Classification of Chinese Standard Y32
Classification of International Standard 85.060
Word Count Estimation 8,857
Date of Issue 2008-12-30
Date of Implementation 2009-09-01
Older Standard (superseded by this standard) QB/T 2808-2006
Drafting Organization Zhejiang Kan Specialty Materials Co., Ltd.
Administrative Organization National Standardization Technical Committee Paper Industry
Regulation (derived from) National Standard Approval Announcement 2008 No.26 (Total No.139)
Proposing organization China Light Industry Federation
Issuing agency(ies) Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China; Standardization Administration of China
Summary This standard specifies the mask paper product categories, requirements, test methods, inspection rules and signs, packaging, transport and storage. This standard applies to the processing of paper mask paper.

GB/T 22927-2008
NATIONAL STANDARD OF THE
PEOPLE’S REPUBLIC OF CHINA
ICS 85.060
Y 32
Respirator paper
口罩纸
ISSUED ON: DECEMBER 30, 2008
IMPLEMENTED ON: SEPTEMBER 01, 2009
Issued by: General Administration of Quality Supervision, Inspection and
Quarantine;
Standardization Administration of the People's Republic of
China.
Table of Contents
Foreword ... 3 
1 Scope ... 4 
2 Normative references ... 4 
3 Product classification ... 5 
4 Technical requirements ... 5 
5 Test methods ... 6 
6 Inspection rules ... 6 
7 Marks, packaging, transportation, storage ... 8 
Annex A (normative) Determination of air permeability of respirator paper ... 9 
Respirator paper
1 Scope
This Standard specifies product classification, requirements, test methods,
inspection rules as well as marks, packaging, transportation and storage of
respirator paper.
This Standard is applicable to processing paper respirator paper.
2 Normative references
The provisions in following documents become the provisions of this Standard
through reference in this Standard. For dated references, the subsequent
amendments (excluding corrigendum) or revisions do not apply to this Standard,
however, parties who reach an agreement based on this Standard are
encouraged to study if the latest versions of these documents are applicable.
For undated references, the latest edition of the referenced document applies.
GB/T 450, Paper and board - Sampling for testing and identification of
machine and cross direction, wire side and felt side
GB/T 451.2, Paper and board - Determination of grammage
GB/T 451.3, Paper and board - Determination of thickness
GB/T 462, Paper, board and pulp - Determination of moisture content of
analytical sample
GB/T 465.2, Paper and board - Determination of tensile strength after
immersion in water
GB/T 1541, Paper and board - Determination of dirt
GB/T 2828.1, Sampling procedures for inspection by attributes - Part 1:
Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot
inspection
GB/T 7974, Paper, board and pulps - Measurement of diffuse blue
reflectance factor - D65 brightness (Diff/Geometry, Outdoor daylight
conditions)
GB/T 10342, Paper - Package and mark
GB/T 10739, Paper, board and pulps - STANDARD atmosphere for
tight. The core shall not be loose.
4.4 The joints of each roll of paper shall not exceed three. The joint shall be
pasted firmly and marked.
4.5 The hygienic indicator shall meet the hygienic requirements of ordinary
respirators in GB 15979. Sampling for continuous production shall be no less
than once a month.
4.6 Raw materials shall be non-toxic, harmless and pollution-free. Prohibit the
use of discarded hygiene products as raw materials or semi-finished products.
5 Test methods
5.1 The sampling, processing and inspection of samples shall be carried out in
accordance with the provisions of GB/T 450 and GB/T 10739.
5.2 Quantitation shall be determined according to GB/T 451.2.
5.3 After determining the layer thickness according to GB/T 451.3, the tightness
is calculated.
5.4 The tensile strength is determined according to GB/T 12914. Use constant
speed drawing method to determine in arbitration.
5.5 The air permeability is determined according to Annex A.
5.6 The wet tensile strength is determined according to GB/T 465.2. Immersion
time is 10min. Use constant speed drawing method to determine in arbitration.
5.7 The brightness is determined according to GB/T 7974.
5.8 The dustiness is determined according to GB/T 1541.
5.9 Fluorescent substance inspection: Randomly take 5 samples of 100cm2
from the sample. Place under 365nm and 254nm UV lamps for inspection.
There shall be no fluorescence reaction in each sample.
5.10 The delivery moisture is determined according to GB/T 462.
5.11 Appearance quality is visually inspected.
6 Inspection rules
6.1 One delivery shall be a lot but not more than 10t.
A.3 Devices
A.3.1 The air permeability tester of respirator paper shall meet the following
conditions:
a) Sample holder: The test area is 2cm2 round sample holder. When
clamping the sample, the sample holder shall avoid the influence of air
leakage on the measurement result. Air leakage shall not exceed 1% of
the measured airflow.
b) Airflow device: A stable and adjustable pressure difference air flow shall
be produced between the two sides of the sample.
c) Sensor: Used to measure the air flow through the sample, the relative error
shall not exceed 2% of the measured value.
d) Display device: Used to display or print the measurement results.
A.3.2 Pressure gauge: Measuring range is 0.25kPa ~ 2.5kPa and the accuracy
is level I.
A.3.3 Standard flow plate: Used to calibrate the air flow rate through the probe
under a certain pressure difference. The accuracy is 0.2%.
A.4 Sample preparation
Conduct sampling according to GB/T 450. Randomly extract samples of which
the total test area is not less than 12 × 2 cm2 = 24 cm2 from the taken samples
as specimens for air permeability determination.
A.5 Steps
A.5.1 Turn on the power and keep the instrument in a stable state.
A.5.2 Turn on the gas source ......