Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

YY/T 1944-2024 English PDF

US$359.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 1944-2024: Particular specification for medical X-ray high voltage generator
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 1944-2024359 Add to Cart 4 days Particular specification for medical X-ray high voltage generator Valid

Similar standards

YY/T 1694   YY/T 1711   YY/T 1537   YY/T 1307   YY/T 1941   

Basic data

Standard ID: YY/T 1944-2024 (YY/T1944-2024)
Description (Translated English): Particular specification for medical X-ray high voltage generator
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 18,182
Date of Issue: 2024-09-29
Date of Implementation: 2026-04-15
Issuing agency(ies): State Drug Administration
Summary: This standard specifies the requirements for medical X-ray high-voltage generators (hereinafter referred to as high-voltage generators) and specifies the corresponding test methods. This standard applies to high-voltage generators of medical X-ray generating devices, including but not limited to high-voltage generators integrated with X-ray tubes.

YY/T 1944-2024: Particular specification for medical X-ray high voltage generator

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
ICS 11.040.50 CCSC43 Pharmaceutical Industry Standards of the People's Republic of China Special technical requirements for medical X-ray high voltage generators Released on 2024-09-29 2026-04-15 implementation The State Drug Administration issued

Table of Contents

Preface III 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Categories 2 5 Requirement 2 5.1 Working conditions 2 5.2 Product performance 2 5.3 Limitation of voltage, current or energy 4 5.4 Leakage Current 4 5.5 Dielectric strength 5 5.6 Limitation of radiated output 5 5.7 Safety measures to prevent excessive radiation output 5 5.8 Loading Factor Range 5 5.9 Electromagnetic compatibility 5 5.10 Environmental testing 5 5.11 Security 5 6 Test methods 6 6.1 Working conditions 6 6.2 Test methods 6 6.3 Limitation of voltage, current or energy 8 6.4 Leakage Current 8 6.5 Dielectric strength 8 6.6 Limitation of radiated output 9 6.7 Safety measures against excessive radiation output 9 6.8 Loading Factor Range 9 6.9 Electromagnetic compatibility 10 6.10 Environmental test 10 6.11 Security 10 Reference 11

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document is proposed by the State Food and Drug Administration. This document is prepared by the National Technical Committee for Standardization of Medical Electrical Appliances, Medical X-ray Equipment and Appliances Standardization Subcommittee (SAC/ TC10/SC1). This document was drafted by. Suzhou Boside Electric Co., Ltd., Liaoning Medical Device Inspection and Testing Institute, Philips Medical (Suzhou) Co., Ltd. Shanghai United Imaging Healthcare Co., Ltd., Siemens X-ray Vacuum Technology (Wuxi) Co., Ltd., General Electric Medical Systems Tong Trading Development (Shanghai) Co., Ltd., Zhuhai Ruiying Technology Co., Ltd., Neusoft Medical Systems Co., Ltd., Nanjing Puai Medical Equipment Co., Ltd. Equipment Co., Ltd., Liaoning Safety Science Research Institute. The main drafters of this document are. Fan Shengfang, Chen Yong, Cai Fang, Zhu Guoping, Lu Shan, Jiang Jie, Feng Rui, Shao Xiaojun, Wang Yanan, Liu Jianjun, Xu, Jun, and Chen, Zhipeng. Special technical requirements for medical X-ray high voltage generators

1 Scope

This document specifies the requirements for medical X-ray high voltage generators (hereinafter referred to as high voltage generators) and describes the corresponding test methods. This document applies to high voltage generators for medical X-ray generating devices, including but not limited to high voltage generators integrated with X-ray tubes. Life tool.

2 Normative references

The contents of the following documents constitute essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB 9706.1 Medical electrical equipment Part 1.General requirements for basic safety and essential performance GB 9706.103 Medical electrical equipment Part 1-3.General requirements for basic safety and essential performance Collateral standard. Diagnostic X Radiation protection of radiation equipment YY/T 0291 Environmental requirements and test methods for medical X-ray equipment YY 9706.102 Medical electrical equipment Part 1-2.General requirements for basic safety and essential performance Collateral standard. Electromagnetic compatibility Requirements and tests definedterms)

3 Terms and definitions

The terms and definitions defined in GB 9706.1, GB 9706.103, YY 9706.102, IEC TR60788 and the following apply to this document. Note. According to the definition in GB 9706.103, unless otherwise specified, in this special standard. The X-ray tube voltage value refers to the peak voltage, ignoring instantaneous changes; The X-ray tube current value refers to the average value. 3.1 Electric power During the specified loading time, the power applied by the high voltage generator to the X-ray tube is equal to the coefficient of the X-ray tube voltage waveform, the X-ray The product of the line tube voltage and the X-ray tube current. P=fUI Where. P ---Electric power; f --- coefficient dependent on the X-ray tube voltage waveform, selected as follows. a) Six-peak high voltage generator f=0.95, or b) twelve-peak high voltage generator or constant voltage high voltage generator f=1.00, or c) For other X-ray high voltage generators, select the most suitable value according to the waveform of the X-ray tube voltage and give the selected value. illustrate;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 1944-2024_English be delivered?

Answer: Upon your order, we will start to translate YY/T 1944-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 1944-2024_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 1944-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.