Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0867-2011 English PDF

US$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0867-2011: Standard test method for electrostatic decay time of nonwoven fabrics
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0867-2011169 Add to Cart 3 days Standard test method for electrostatic decay time of nonwoven fabrics Valid

Similar standards

YY/T 0969   YY/T 0487   YY 0484   YY/T 0331   YY/T 0866   

Basic data

Standard ID: YY/T 0867-2011 (YY/T0867-2011)
Description (Translated English): Standard test method for electrostatic decay time of nonwoven fabrics
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C48
Classification of International Standard: 11.140
Word Count Estimation: 7,791
Date of Issue: 2011-12-31
Date of Implementation: 2013-06-01
Regulation (derived from): State Food and Drug Administration Notice 2011 No. 106; industry standard filing Notice 2013 No. 6 (No. 162 overall)
Issuing agency(ies): State Food and Drug Administration
Summary: This standard specifies the nonwovens electrostatic decay time of testing methods. This standard applies to a static requirements of the premises used in film or sheet nonwovens electrostatic decay time of testing.

YY/T 0867-2011: Standard test method for electrostatic decay time of nonwoven fabrics

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard test method for electrostatic decay time of nonwoven fabrics ICS 11.140 C48 People's Republic of China pharmaceutical industry standards Test Methods nonwovens electrostatic decay time Issued on. 2011-12-31 2013-06-01 implementation State Food and Drug Administration issued

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. Please note that some of the content of this document may involve patents. Distribution of this document Institutions do not assume the responsibility to identify these patents. This standard was proposed by the State Food and Drug Administration. This standard is under the jurisdiction of the State Food and Drug Administration, Beijing Medical Device Quality Supervision and Inspection Center. This standard was drafted. Beijing Medical Device Testing. The main drafters of this standard. Huguang Yong, Yue Weihua, Chen Hong. Test Methods nonwovens electrostatic decay time

1 Scope

This standard specifies the test method for nonwovens electrostatic decay time. This standard applies to static film or sheet has a place requirements used in the non-woven fabric of electrostatic decay time of the test.

2 Terms and definitions

The following terms and definitions apply to this document. 2.1 Nonwovens nonwoven Orientation or randomly oriented fibers by friction, cohesion or adhesive or a combination of these methods combined with each other and made of sheet, web Or batt. It does not include paper, woven fabrics, tufted fabric, stitched fabric with stitching yarn and felt wet milling products. The fibers can be used Be natural fibers or chemical fibers; can be short fibers, filaments or fibers was formed on the spot. [GB/T 5709-1997, the definition 2.3.1] 2.2 Static decay electrostaticdecay Since the charge on the charged body portion of the ground leaving or all of the process of disappearing. [INDAWSP40.2 (08) A, the definition 3.1] 2.3 Static voltage decay time staticdecaytime Voltage electrified body down to the initial value of a given percentage of the time required. [GB/T 15463-2008, terminology 4.30] Test Method 3 3.1 Test Principle A predetermined voltage applied to the sample, the sample to be charged after a certain stable value, the charging is stopped, the sample was ground while measuring the sample brought Voltage decay time required for a certain percentage. 3.2 Instrument and material appliances 3.2.1 static decay meter Should meet the following basic requirements. a) gives the sign of at least 5000V high voltage; b) with a voltmeter, timing device (time resolution 0.01s), to detect the amount of charge and the charge to decay to the preset limit time spent; c) high-voltage electrostatic generator, capable of applying a voltage of 0V ~ ± 5000V sample stability claim their 30s plus or minus deviation of not More than 5%;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0867-2011_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0867-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0867-2011_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0867-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.