YY/T 0747-2009 English PDFUS$279.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YY/T 0747-2009: XZ1-4/250 Therapy X-ray tube Status: Valid
Basic dataStandard ID: YY/T 0747-2009 (YY/T0747-2009)Description (Translated English): XZ1-4/250 Therapy X-ray tube Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended) Classification of Chinese Standard: C43 Classification of International Standard: 11.040.60 Word Count Estimation: 12,129 Date of Issue: 2009-11-25 Date of Implementation: 2010-12-01 Quoted Standard: GB/T 191; GB/T 1804; GB/T 2828.1; GB/T 2829; GB/T 2987; GB/T 4597; GB/T 10149; GB/T 12078-2012; GB/T 12079-2012; SJ/T 10624; SJ/T 10732 Regulation (derived from): Industry standard filing Notice 2010 No. 2 (No. 122 overall) Issuing agency(ies): State Food and Drug Administration Summary: This standard specifies the XZ1-4/250 therapeutic X-ray tube definitions, terminology, symbols and nomenclature, requirements, test methods, inspection rules and signs, packaging, transportation, storage and so on. This standard applies to XZ1-4/250 therapeutic X-ray tube (referred to X-ray tube), the X-ray tube housing is made of glass, mainly for deep radiotherapy machines. YY/T 0747-2009: XZ1-4/250 Therapy X-ray tube---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.XZ1-4/250 Therapy X-ray tube ICS 11.040.60 C43 People's Republic of China pharmaceutical industry standards XZ1-4/250 therapeutic X-ray tube Posted 2009-11-15 2010-12-01 implementation State Food and Drug Administration issued ForewordThis standard is based on GB/T 13797-2009 "Medical X-ray tube General technical conditions" and GB/T 12079-2012 "X-ray tube light Electrical performance test method "on the basis of written. This standard was proposed by the State Food and Drug Administration. This standard by the National Standardization Technical Committee on Medical Electrical medical X-ray equipment and utensils Standardization Technical Committee (SAC/TC10 / SC1) centralized. This standard was drafted. Hangzhou Wandong Electronics Co., Ltd., Liaoning Medical Device Testing. The main drafters of this standard. Hu Youcheng, Yu Xiao Mei, Bairong Qing, Ding Xu, Chen Wei. XZ1-4/250 therapeutic X-ray tube1 ScopeThis standard specifies the XZ1-4/250 definition of therapeutic X-ray tube, terminology, symbols and nomenclature, requirements, test methods, inspection rules and Signs, packaging, transportation, storage and so on. This standard applies to XZ1-4/250 therapeutic X-ray tube (referred to as the X-ray tube), the X-ray tube housing is made of glass, mainly for Deep radiotherapy machines.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. GB/T 191 Packaging - Pictorial signs GB/T 1804 General tolerances Tolerances for linear and angular dimensions without individual tolerance GB/T 2828.1 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch inspection sampling plan GB/T 2829 periodic inspection Sampling procedures and tables (suitable for process stability test) GB/T 2987 Tube Parameter Symbol GB/T 4597 tubes vocabulary GB/T 10149 X-ray equipment for medical terminology and symbols GB/T 12078-2012 X-ray tube General specification GB/T 12079-2012 X-ray tube Optical Performance Test Method SJ/T 10624 X-ray tube life test method SJ/T 10732 tube type designation 3 Definitions, terminology, symbols and names 3.1 Definitions, terminology, symbols GB/T 2987, GB/T 4597, the definition of GB/T 10149 and GB/T 12078 established the terms and symbols apply to this standard. Such as GB/T 4597 and GB/T 10149 terminology is inconsistent, priority GB/T 10149 term use. 3.2 Naming X-ray tube in accordance with SJ/T 10732 is named as follows. XZ Represented therapeutic X-ray tube A sequence number -4 Represents nominal power (kW) Represents the nominal X-ray tube voltage (kV) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YY/T 0747-2009_English be delivered?Answer: Upon your order, we will start to translate YY/T 0747-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YY/T 0747-2009_English with my colleagues?Answer: Yes. The purchased PDF of YY/T 0747-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |