Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YY/T 0745-2009 English PDF

US$189.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YY/T 0745-2009: particular specification for remote control radioscopy X-ray equipment
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0745-2009189 Add to Cart 3 days particular specification for remote control radioscopy X-ray equipment Valid

Similar standards

YY/T 0741   YY/T 0744   YY/T 0794   YY/T 0740   YY/T 0746   YY/T 0742   

Basic data

Standard ID: YY/T 0745-2009 (YY/T0745-2009)
Description (Translated English): particular specification for remote control radioscopy X-ray equipment
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 8,858
Date of Issue: 2009-11-15
Date of Implementation: 2010-12-01
Quoted Standard: GB 9706.1-2007; GB 9706.3-2000; GB 9706.11-1997; GB 9706.12-1997; GB 9706.14-1997; GB 9706.15-2008; GB/T 10149; YY/T 0106-2008; YY/T 0291-2007; YY/T 0505-2005; YY/T 0608-2007
Regulation (derived from): Industry standard filing Notice 2010 No. 2 (No. 122 overall)
Issuing agency(ies): State Food and Drug Administration
Summary: This standard specifies the remote fluoroscopy X-ray machine (hereinafter referred to as remote fluoroscopy) composition, requirements and test methods. This standard applies to the upright fluoroscopy X-ray machine with a remote perspective, a perspective view of the remote machine for medical diagnostic units for routine fluoroscopy use. This standard does not apply to have the common feature perspective, diagnostic X-ray machine.

YY/T 0745-2009: particular specification for remote control radioscopy X-ray equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
special specification for remote control radioscopy X-ray equipment ICS 11.040.50 C43 People's Republic of China Pharmaceutical Industry Standard Remote control of X - ray machine dedicated technical conditions 2009-11-15 release 2010-12-01 implementation State Food and Drug Administration issued

Foreword

This standard by the National Medical Electrical Standardization Technical Committee of medical X-ray equipment and appliances standardized sub-technical committee (SAC / TC10/SC1). The main drafting of this standard. Shanghai Medical Devices Factory Co., Ltd., Liaoning Province, medical equipment testing. The main drafters of this standard. Yuan Jufen, Dong Kaiyi, Sun Zhiyong, Meng Nanjin. Remote control of X - ray machine dedicated technical conditions

1 Scope

This standard specifies the composition, requirements and test methods of the remote control perspective X-ray machine (hereinafter referred to as remote control perspective machine). This standard applies to the remote perspective X-ray machine for standing perspective, which can be used for routine medical examination of medical diagnostic units Use. This standard does not apply to general diagnostic X-ray machines with perspective functions.

2 normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) GB 9706.3-2000 Medical electrical equipment - Part 2. Particular requirements for the safety of high pressure generators for diagnostic X - ray devices (Idt IEC 60601-2-7..1998) GB 9706.11-1997 Medical electrical equipment - Part 2. Medical diagnostic X - ray source assemblies and X - ray tube assemblies - Safety - specific Requirements (idt IEC 60601-2-28..1993) Medical electrical equipment - Part 1. General requirements for safety III. Parallel standard diagnosis of X - ray radiation General requirements for protection (idt IEC 60601-1-3..1994) Medical electrical equipment - Part 2. Particular requirements for the safety of ancillary equipment for X - ray equipment (idt IEC ) GB 9706.14-1997. 60601-2-32..1994) GB 9706.15-2008 Medical electrical equipment - Part 1-1. General safety requirements Parallel standard. Medical electrical system safety (IEC 60601-1-1..2000, IDT) GB/T 10149 Medical X - ray equipment - Terms and symbols General specification for medical diagnostic X - ray machines YY/T 0106-2008 Medical diagnostic X - ray equipment - Environmental requirements and test methods YY/T 0291-2007 Medical electrical equipment - Part 1-2. General requirements for safety - Parallel standards. Electromagnetic compatibility requirements and tests YY/T 0505-2005 (IEC 60601-1-2..2001, IDT) General technical conditions for medical radiography of medical radiography (X - ray image intensifier) YY/T 0608-2007

3 terminology

The terms and definitions established in GB/T 10149 apply to this standard.

4 composition

Remote control of the main components of the machine. a) X-ray generating means; b) remote control console; c) patient support device; d) Image intensifier TV system.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0745-2009_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0745-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0745-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0745-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.