YY/T 0739-2009: particular specification for wall stand of medical X-ray equipment
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YY/T 0739-2009149 Add to Cart 3 days particular specification for wall stand of medical X-ray equipment Valid

Similar standards

YY/T 0744   YY/T 0741   YY/T 0794   YY/T 0740   YY/T 0746   YY/T 0742   

Basic data

Standard ID: YY/T 0739-2009 (YY/T0739-2009)
Description (Translated English): particular specification for wall stand of medical X-ray equipment
Sector / Industry: Medical Device & Pharmaceutical Industry Standard (Recommended)
Classification of Chinese Standard: C43
Classification of International Standard: 11.040.50
Word Count Estimation: 5,578
Date of Issue: 2009-11-15
Date of Implementation: 2010-12-01
Quoted Standard: GB 9706.1-2007; GB 9706.12-1997; GB 9706.14-1997; GB/T 10149; YY 0076-1992; YY/T 0291-2007; YY 0505-2005
Regulation (derived from): Industry standard filing Notice 2010 No. 2 (No. 122 overall)
Issuing agency(ies): State Food and Drug Administration
Summary: This standard specifies: Medical X-ray photography vertical rack (hereinafter referred to as photographic frame) requirements and test methods. This standard applies to medical diagnostic X-ray equipment used in conjunction Vertical photographic frame.

YY/T 0739-2009: particular specification for wall stand of medical X-ray equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
special specification for wall stand of medical X-ray equipment ICS 11.040.50 C43 People's Republic of China Pharmaceutical Industry Standard Medical X - ray vertical camera special technical conditions 2009-11-15 release 2010-12-01 implementation State Food and Drug Administration issued

Foreword

This standard by the National Medical Electrical Standardization Technical Committee of medical X-ray equipment and appliances standardized sub-technical committee (SAC/TC 10/SC1). The drafting of this standard. Liaoning Province, medical equipment testing, Neusoft Philips medical equipment system limited liability company. The main drafters of this standard. single Xu, Guan Hong, Wang Che, Wang Li Feng. Medical X - ray vertical camera special technical conditions

1 Scope

This standard specifies the medical X-ray vertical camera (hereinafter referred to as photography) requirements and test methods. This standard applies to medical diagnostic X-ray equipment with the use of vertical camera.

2 normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard. GB 9706.1-2007 Medical electrical equipment - Part 1. General requirements for safety (IEC 60601-1. 1988, IDT) Medical electrical equipment - Part 1. General requirements for safety III. Parallel standard diagnostic X - ray equipment General requirements for radiation protection (idt IEC 60601-1-3..1994) GB 9706.14-1997 Medical electrical equipment - Part 2. Particular requirements for the safety of ancillary equipment for X - ray equipment (Idt IEC 60601-2-32..1994) GB/T 10149 Medical X - ray equipment - Terms and symbols Technical specification for coating classification of metal parts YY 0076-1992 Medical environmental requirements and test methods for medical X - ray equipment YY/T 0291-2007 YY 0505-2005 Medical electrical equipment - Part 1-2. General requirements for safety - Parallel standards. Electromagnetic compatibility requirements and tests (IEC 60601-1-2..2001, IDT)

3 terms and definitions

The terms and definitions established in GB/T 10149 apply to this standard.

4 requirements

4.1 working conditions 4.1.1 Environmental conditions Unless otherwise specified, the working conditions of the photographic frame shall be met. a) Ambient temperature. 10 ° C to 40 ° C; b) relative humidity. 30% to 75%; c) Atmospheric pressure. 700hPa ~ 1060hPa. 4.1.2 Power supply conditions The product standard shall specify the power supply conditions of the camera frame. 4.2 Mechanical movement range The product standard shall specify the range of mechanical movement of the photographic frame. 4.3 Braking force The movement part of the mechanical device shall be provided with a brake device (except in the case of a suspension device which does not require braking), the linear motion part Sub-system power should be not less than 100N; rotating part of the braking force should be specified by the product standards. 4.4 start force Need to manually operate the linear part of the movement, the starting force should not be greater than 50N, rotating part of the braking force should be specified by the product standards.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YY/T 0739-2009_English be delivered?

Answer: Upon your order, we will start to translate YY/T 0739-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YY/T 0739-2009_English with my colleagues?

Answer: Yes. The purchased PDF of YY/T 0739-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.