YS/T 746.9-2010: Methods for chemical analysis of lead-free tin-based solders. Part 9: Determination of zinc content. Flame atomic absorption spectrometric method and Na2EDTA titrimetric method
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 746.9-2010239 Add to Cart 3 days Methods for chemical analysis of lead-free tin-based solders. Part 9: Determination of zinc content. Flame atomic absorption spectrometric method and Na2EDTA titrimetric method Valid

Similar standards

GB/T 3884.2   GB/T 3884.1   YS/T 710.6   YS/T 746.17   YS/T 746.12   YS/T 746.10   

Basic data

Standard ID: YS/T 746.9-2010 (YS/T746.9-2010)
Description (Translated English): Methods for chemical analysis of lead-free tin-based solders. Part 9: Determination of zinc content. Flame atomic absorption spectrometric method and Na2EDTA titrimetric method
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H13
Classification of International Standard: 77.040.30
Word Count Estimation: 9,936
Date of Issue: 2010-11-22
Date of Implementation: 2011-03-01
Regulation (derived from): MIIT (2010) No. 126
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the base solder lead-free solder Determination of zinc content. This standard applies to lead-free tin-based solder in the zinc content. Measuring range: 0. 0010% to 0. 100%

YS/T 746.9-2010: Methods for chemical analysis of lead-free tin-based solders. Part 9: Determination of zinc content. Flame atomic absorption spectrometric method and Na2EDTA titrimetric method



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of lead-free tin-based solders.Part 9. Determination of zinc content.Flame atomic absorption spectrometric method and Na2EDTA titrimetric method ICS 77.040.30 H13 People's Republic of China Nonferrous Metals Industry Standard No Tin Lead-based solder chemical analysis Part 9. Determination of zinc content Flame atomic absorption spectrometry and Na2EDTA titration Part 9. Determinationofzinccontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 746 "non-Pb-based solder chemical analysis method" is divided into 17 parts. --- Part 1 Determination of tin content Coke sexual gallic acid Covering - lead nitrate titration method --- Part 2 of silver content - Flame atomic absorption spectrometry and potentiometric titration with potassium thiocyanate --- Part 3 of copper content - Flame atomic absorption spectrometry and titration with sodium thiosulfate --- Part 4 of lead content - Flame Atomic Absorption Spectrometry --- Part 5 of bismuth content - Flame atomic absorption spectrometry and titration Na2EDTA --- Part 6 of antimony content - Flame Atomic Absorption Spectrometry --- Part 7 Determination of iron content by flame atomic absorption spectrometry --- Part 8 of arsenic content of arsenic, antimony molybdenum blue spectrophotometric method --- Part 9 Determination of zinc content by flame atomic absorption spectrometry and titration Na2EDTA Part 10 Determination of aluminum content --- first electrothermal atomic absorption spectrometry --- Part 11 of cadmium content - Flame Atomic Absorption Spectrometry --- Part 12 Determination of indium titration Na2EDTA --- Part 13 Determination of nickel content by flame atomic absorption spectrometry --- Part 14 Determination of the phosphorus content of the first crystal violet - heteropoly acid phosphovanadomolybdate spectrophotometry --- Part 15 Determination of germanium content salicylfluorone spectrophotometry --- Part 16 Determination of rare earth Arsenazo Ⅲ spectrophotometry --- Part 17 silver, copper, lead, bismuth, antimony, iron, arsenic, zinc, aluminum, cadmium, nickel, indium content was measured by inductively coupled plasma optical emission Spectroscopy Part is divided into 9 parts. This section is in accordance with GB/T 1.1-2009 given rules drafted. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is drafted. Yunnan Tin Group Co., Ltd. Participated in the drafting of this section. Guangxi China Tin Group Co., Ltd. Yunnan Hualian Zinc indium. The main drafters of this section. Dingxi Bo, of Liu Sheng, Xu Dengqiong, Ho Chi armor, Huang Mei, Luli Fei, Wang Juping, Ma Yan, Priscilla, Xiecai Fei, Wang Mei, Yang Shaohui. No Tin Lead-based solder chemical analysis Part 9. Determination of zinc content Flame atomic absorption spectrometry and Na2EDTA titration Method 1 flame atomic absorption spectrometry

1 Scope

YS/T 746 This section provides lead-free tin-based solders Determination of zinc content. This section applies to the determination of tin-based solders without zinc content. Measurement range. 0.0010% to 0.100%.

2 Method summary

Sample hydrochloric acid - hydrogen peroxide dissolved in hydrochloric acid - hydrobromide exclude volatile tin, antimony in nitric acid medium, flame atomic absorption spectrometry At a wavelength of 213.9nm, with flame atomization, air - acetylene flame measured absorbance of zinc.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 hydrochloric acid (ρ1.19g/mL), pure class distinctions. 3.2 nitrate (ρ1.42g/mL), pure class distinctions. 3.3 Hydrogen peroxide (30%). 3.4 hydrobromide (ρ1.49g/mL). 3.5 nitric acid (11). HCl 3.6 - hydrobromic acid (11). 3.7 standard zinc stock solution. Accurately weigh 0.1000g zinc metal (≥99.99%), zinc placed in 200mL beaker, add 20mL nitrate Acid (3.5), cover sheet pan, heat gently to dissolve, cooled to room temperature and transferred to 1000mL volumetric flask, dilute to the mark with water, mix and transferred to plastic bottles In storage. This solution 1mL containing 100μg zinc. 3.8 Zinc standard solution. Pipette 10.00mL standard zinc stock solution (3.7) in 100mL volumetric flask, add 2mL nitric acid (3.2) with Diluted with water to the mark, mix and transferred to a plastic bottle storage solution 1mL containing 10μg zinc.

4 Instrument

Atomic absorption spectrometer, with zinc hollow cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic concentration. a solution in the matrix is consistent with the measured solution, characterized in zinc concentration should not exceed 0.01μg/mL. --- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%; With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 746.9-2010_English be delivered?

Answer: Upon your order, we will start to translate YS/T 746.9-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 746.9-2010_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 746.9-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.