YS/T 746.7-2010 English PDFUS$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 746.7-2010: Methods for chemical analysis of lead-free tin-based solders. Part 7: Determination of iron content. Flame atomic absorption spectrometric method Status: Valid
Basic dataStandard ID: YS/T 746.7-2010 (YS/T746.7-2010)Description (Translated English): Methods for chemical analysis of lead-free tin-based solders. Part 7: Determination of iron content. Flame atomic absorption spectrometric method Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.040.30 Word Count Estimation: 6,681 Date of Issue: 2010-11-22 Date of Implementation: 2011-03-01 Regulation (derived from): MIIT (2010) No. 126 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the base solder lead-free solder iron content determination. This standard applies to lead-free tin-based solder iron content. Measuring range: 0. 0010% to 0. 150% YS/T 746.7-2010: Methods for chemical analysis of lead-free tin-based solders. Part 7: Determination of iron content. Flame atomic absorption spectrometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of lead-free tin-based solders.Part 7. Determination of iron content.Flame atomic absorption spectrometric method ICS 77.040.30 H13 People's Republic of China Nonferrous Metals Industry Standard Chemical analysis of lead - free solder Part 7. determination of iron content Flame atomic absorption spectrometry Part 7. Determination ofironcontent- 2010-11-22 release 2011-03-01 implementation Issued by the Ministry of Industry and Information Technology of the People's Republic of China ForewordYS/T 746 "lead-free solder based on the chemical analysis method" is divided into 17 parts. Determination of tin content - Part 1. Determination of tin content - Coking of gallic acid - Titanium nitrate titration - Part 2 Determination of silver content Flame atomic absorption spectrometry and potassium thiocyanate potentiometric titration Part 3. Determination of copper content - Flame atomic absorption spectrometric method and sodium thiosulfate titration method Part 4. Determination of Lead Content - Flame Atomic Absorption Spectrometry Part 5 Determination of bismuth content - Flame atomic absorption spectrometric method and Na2EDTA titration method Part 6. Determination of antimony content - Flame atomic absorption spectrometric method Part 7. Determination of iron content - Flame atomic absorption spectrometric method Part 8 - Determination of arsenic content - Arsenic, antimony, molybdenum blue spectrophotometric method Part 9. Determination of zinc content - Flame atomic absorption spectrometric method and Na2EDTA titration method Part 10. Determination of aluminum content - Electrothermal atomic absorption spectrometric method Part 11. Determination of cadmium content - Flame atomic absorption spectrometric method Part 12. Determination of indium content - Na2EDTA titration method Part 13. Determination of nickel content - Flame atomic absorption spectrometric method - Part 14 - Determination of phosphorus content - Crystalline violet - phosphorous vanadium molybdenum heteropoly acid spectrophotometric method Part 15. Determination of germanium content - Salicyl - based fluorone spectrophotometric method - Part 16 - Determination of rare earth content - Arsenazo III spectrophotometric method Determination of silver, copper, lead, bismuth, antimony, iron, arsenic, zinc, aluminum, cadmium, nickel and indium Inductively coupled plasma emission Spectrum method This section is part 7. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part is the national nonferrous Metals Standardization Technical Committee (SAC/TC243). This part of the drafting unit. Guangxi Huaxi Group Co., Ltd. This part participates in the drafting unit. Yunnan tin industry group limited liability company, Yunnan Hualian Zinc Indium Co., Ltd. The main drafters of this part. Lin Wen-chen, Xie Xue-zhen, Su Aiping, Zhang Limei, Wang Juping, Zhang Jecheng. Chemical analysis of lead - free solder Part 7. determination of iron content Flame atomic absorption spectrometry1 ScopeYS/T 746 This section specifies the determination of iron content in lead-free solder. This part is applicable to the determination of iron content in lead-free solder. Measurement range. 0.0010% ~ 0.150%.2 method summaryThe sample was mixed with acid-dissolving material, washed with hydrochloric acid-hydrobromide tin, antimony, in hydrochloric acid medium at an atomic absorption spectrometer wavelength of 248.3 nm , With flame atomizer, air - acetylene flame, measure the absorbance of iron.3 reagentUnless otherwise stated, only the reagents identified as analytical reagents and distilled or deionized water or comparable purity were used in the analysis. 3.1 hydrochloric acid (ρ1.19g/mL), excellent grade pure. 3.2 Hydrochloric acid (1 1). 3.3 nitric acid (ρ1.42g/mL). 3.4 Mixed acid. 30 mL nitric acid, 70 mL hydrochloric acid and 100 mL water. 3.5 Hydrogen peroxide (30%). 3.6 hydrobromic acid (ρ1.49g/mL). 3.7 Hydrochloric acid - hydrobromic acid (1 1). 3.8 Thiourea solution (50 g/L). 3.9 iron standard solution. Weigh 0.1000g metallic iron (≥ 99.99%), placed in 250mL beaker, add 20mL hydrochloric acid (3.2), 3 drops of hydrogen peroxide (3.5), slightly heat dissolved completely, remove the cooling to room temperature, into the 1000mL volumetric flask, diluted with water to the mark, mix. 1 mL of this solution contains 100 μg of iron.4 instrumentsAtomic absorption spectrometer, with iron hollow cathode lamp. In the best working conditions of the instrument, who can meet the following indicators can be used. --- Characteristic concentration. In the solution consistent with the substrate of the measurement solution, the characteristic concentration of iron should not be more than 0.033μg/mL; Precision. the maximum concentration of the standard solution measured 10 times the absorbance, the standard deviation should not exceed 1.0% of the average absorbance; The standard deviation should not exceed the maximum of 10 absorbance measured with the lowest concentration of the standard solution (not the "zero" concentration standard solution) Concentration Standard solution 0.5% of the average absorbance; --- working curve linear. the working curve by the concentration of divided into five sections, the highest section of the difference between the absorbance difference and the lowest of the difference in absorbance Ratio, should not be less than 0.7. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 746.7-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 746.7-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 746.7-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 746.7-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |