YS/T 746.6-2010 English PDFUS$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 746.6-2010: Methods for chemical analysis of lead-free tin-based solders. Part 6: Determination of antimony content. Flame atomic absorption spectrometric method Status: Valid
Basic dataStandard ID: YS/T 746.6-2010 (YS/T746.6-2010)Description (Translated English): Methods for chemical analysis of lead-free tin-based solders. Part 6: Determination of antimony content. Flame atomic absorption spectrometric method Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.040.30 Word Count Estimation: 6,619 Date of Issue: 2010-11-22 Date of Implementation: 2011-03-01 Regulation (derived from): MIIT (2010) No. 126 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the base solder lead-free solder Determination of antimony content. This standard applies to lead-free tin-based solder in the antimony content. Measuring range: 0. 0150% ~ 5. 50%. YS/T 746.6-2010: Methods for chemical analysis of lead-free tin-based solders. Part 6: Determination of antimony content. Flame atomic absorption spectrometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of lead-free tin-based solders.Part 6. Determination of antimony content.Flame atomic absorption spectrometric method ICS 77.040.30 H13 People's Republic of China Nonferrous Metals Industry Standard No Tin Lead-based solder chemical analysis Part 6. Determination of antimony content Flame Atomic Absorption Spectrometry Part 6. Determinationofantimonycontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 746 "non-Pb-based solder chemical analysis method" is divided into 17 parts. --- Part 1 Determination of tin content Coke sexual gallic acid Covering - lead nitrate titration method --- Part 2 of silver content - Flame atomic absorption spectrometry and potentiometric titration with potassium thiocyanate --- Part 3 of copper content - Flame atomic absorption spectrometry and titration with sodium thiosulfate --- Part 4 of lead content - Flame Atomic Absorption Spectrometry --- Part 5 of bismuth content - Flame atomic absorption spectrometry and titration Na2EDTA --- Part 6 of antimony content - Flame Atomic Absorption Spectrometry --- Part 7 Determination of iron content by flame atomic absorption spectrometry --- Part 8 of arsenic content of arsenic, antimony molybdenum blue spectrophotometric method --- Part 9 Determination of zinc content by flame atomic absorption spectrometry and titration Na2EDTA Part 10 Determination of aluminum content --- first electrothermal atomic absorption spectrometry --- Part 11 of cadmium content - Flame Atomic Absorption Spectrometry --- Part 12 Determination of indium titration Na2EDTA --- Part 13 Determination of nickel content by flame atomic absorption spectrometry --- Part 14 Determination of the phosphorus content of the first crystal violet - heteropoly acid phosphovanadomolybdate spectrophotometry --- Part 15 Determination of germanium content salicylfluorone spectrophotometry --- Part 16 Determination of rare earth Arsenazo Ⅲ spectrophotometry --- Part 17 silver, copper, lead, bismuth, antimony, iron, arsenic, zinc, aluminum, cadmium, nickel, indium content was measured by inductively coupled plasma optical emission Spectroscopy Part is divided into 6 sections. This section is in accordance with GB/T 1.1-2009 given rules drafted. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is drafted. Guangxi China Tin Group Co., Ltd. This section participating units. Yunnan Tin Group Co., Ltd., Red River Exit Inspection and Quarantine. The main drafters of this section. Lin cream, Xiexue Zhen, Shiru Xiang, Zhu Rui, Jiang Village stretch, Hu Yu Wei. No Tin Lead-based solder chemical analysis Part 6. Determination of antimony content Flame Atomic Absorption Spectrometry1 ScopeYS/T 746 This section specifies the determination method without Tin Solder by antimony content. This section applies to the determination of tin-based solder no antimony content. Measurement range. 0.0150% - 5.50%.2 Method summarySample was dissolved with a mixed acid sample, in a mixed acid medium, atomic absorption spectrometer at a wavelength of 217.6nm with flame atomizer, Air - acetylene flame was measured antimony absorbance.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 hydrochloride (ρ1.19g/mL). Nitrate 3.2 (ρ1.42g/mL). 3.3 mixed acid. 30mL nitric acid, 70mL of hydrochloric acid and 100mL of water. 3.4 thiourea solution (50g/L). 3.5 Antimony standard stock solution. Take 0.5986g dried 2h antimony trioxide (99.99%) at 105 ℃ that burn into 250mL Cup, was added 50mL of hydrochloric acid (3.1), dissolved completely transferred to 500mL volumetric flask, was added 50mL of hydrochloric acid (3.1), diluted with water to Volume, and mix. This solution 1mL 1mg containing antimony. 3.6 Antimony standard solution. Pipette 50.00mL antimony standard stock solution in 500mL flask, add 50mL of hydrochloric acid (3.1), dilute with water Diluted to volume, and mix. This solution 1mL containing 100μg antimony.4 InstrumentAtomic absorption spectrometer, with antimony hollow cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic concentration. a solution in the measurement matrix consistent solution, the concentration of antimony features should not exceed 0.14μg/mL; --- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed the average absorbance of 1.0%; With the lowest concentration of standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum 0.5% concentration of the standard average absorbance; --- Linear curve. The curve is divided into five sections according to concentration, absorbance difference between the absorbance difference between the highest and the lowest segment of the segment Ratio of not less than 0.7. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 746.6-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 746.6-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 746.6-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 746.6-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |