YS/T 746.3-2010 English PDFUS$239.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 746.3-2010: Methods for chemical analysis of tin-based lead-free solders. Part 3: Determination of copper content. Flame atomic absorption spectrometric method and sodium thiosulfate titrimetric method Status: Valid
Basic dataStandard ID: YS/T 746.3-2010 (YS/T746.3-2010)Description (Translated English): Methods for chemical analysis of tin-based lead-free solders. Part 3: Determination of copper content. Flame atomic absorption spectrometric method and sodium thiosulfate titrimetric method Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.040.30 Word Count Estimation: 9,962 Date of Issue: 2010-11-22 Date of Implementation: 2011-03-01 Regulation (derived from): MIIT (2010) No. 126 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the base solder lead-free solder copper content determination. This standard applies to lead-free tin-based solder in the copper content. Measuring range: 0. 010% 1. 000%. YS/T 746.3-2010: Methods for chemical analysis of tin-based lead-free solders. Part 3: Determination of copper content. Flame atomic absorption spectrometric method and sodium thiosulfate titrimetric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of tin-based lead-free solders.Part 3. Determination of copper content.Flame atomic absorption spectrometric method and sodium thiosulfate titrimetric method ICS 77.040.30 H13 People's Republic of China Nonferrous Metals Industry Standard No Tin Lead-based solder chemical analysis Part 3. Determination of copper content Flame atomic absorption spectrometry and Sodium thiosulfate titration Part 3. Determinationofcoppercontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 746 "non-Pb-based solder chemical analysis method" is divided into 17 parts. --- Part 1 Determination of tin content Coke sexual gallic acid Covering - lead nitrate titration method --- Part 2 of silver content - Flame atomic absorption spectrometry and potentiometric titration with potassium thiocyanate --- Part 3 of copper content - Flame atomic absorption spectrometry and titration with sodium thiosulfate --- Part 4 of lead content - Flame Atomic Absorption Spectrometry --- Part 5 of bismuth content - Flame atomic absorption spectrometry and titration Na2EDTA --- Part 6 of antimony content - Flame Atomic Absorption Spectrometry --- Part 7 Determination of iron content by flame atomic absorption spectrometry --- Part 8 of arsenic content of arsenic, antimony molybdenum blue spectrophotometric method --- Part 9 Determination of zinc content by flame atomic absorption spectrometry and titration Na2EDTA Part 10 Determination of aluminum content --- first electrothermal atomic absorption spectrometry --- Part 11 of cadmium content - Flame Atomic Absorption Spectrometry --- Part 12 Determination of indium titration Na2EDTA --- Part 13 Determination of nickel content by flame atomic absorption spectrometry --- Part 14 Determination of the phosphorus content of the first crystal violet - heteropoly acid phosphovanadomolybdate spectrophotometry --- Part 15 Determination of germanium content salicylfluorone spectrophotometry --- Part 16 Determination of rare earth Arsenazo Ⅲ spectrophotometry --- Part 17 silver, copper, lead, bismuth, antimony, iron, arsenic, zinc, aluminum, cadmium, nickel, indium content was measured by inductively coupled plasma optical emission Spectroscopy This is Part 3. This section is in accordance with GB/T 1.1-2009 given rules drafted. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is drafted. Yunnan Tin Group Co., Ltd. Participated in the drafting of this section. Yunnan Hualian Zinc Co. indium. The main drafters of this section. Tang Feng Su, cloud Kun, Xie Hui-fang, Wang Juping, Zhang Wen Cheng, Lang Fu Min, Wang Jian, Wang Guomei. No Tin Lead-based solder chemical analysis Part 3. Determination of copper content Flame atomic absorption spectrometry and Sodium thiosulfate titration Method 1 flame atomic absorption spectrometry1 ScopeYS/T 746 This section provides lead-free tin-based solders Determination of copper content. This section applies to the determination of tin-based solder without copper content. Measurement range. 0.010% to 1.000%.2 Method summarySamples with hydrochloric acid - nitric acid mixture decomposed in hydrochloric acid - nitric acid, mixed media, atomic absorption spectrometer at a wavelength of 324.7nm, with Flame atomizer, air - acetylene flame measured absorbance.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. Nitrate 3.1 (ρ1.42g/mL). 3.2 hydrochloride (ρ1.19g/mL). 3.3 hydrochloric acid - nitric acid mixed. 300mL of hydrochloric acid (3.2) and 100mL nitric acid (3.1) and mixed. 3.4 Copper Standard stock solution. Weigh 0.5000g copper (≥99.99%), placed in 200mL beaker, was added 20mL of hydrochloric acid - nitric acid mixture Co acid (3.3), heat gently to dissolve completely, boil drive out nitrogen oxides, remove the cooled to room temperature and transferred to 1000mL volumetric flask, diluted with water To the mark, and mix. This solution 1mL containing 500μg copper. 3.5 Copper Standard Solution. Pipette 10.00mL copper standard stock solution (3.4) in 500mL volumetric flask, was added 5mL of hydrochloric acid - nitric acid mixture Co acid (3.3), dilute to the mark and mix. This solution 1mL containing 10μg copper.4 InstrumentAtomic absorption spectrometer, with copper hollow cathode lamp. Under optimum working conditions for those who can reach the following indicators can be used. --- Characteristic concentration. a solution in the matrix is consistent with the measured solution, features copper concentration should be less than 0.035μg/mL; --- Precision. measure 10 times the absorbance of the highest concentration of the standard solution, the standard deviation should not exceed the average absorbance of the concentration standard Standard solution (not "zero" concentration of the standard) measuring the absorbance of 10 times, the standard deviation should not exceed the maximum concentration of the standard level 0.5% average absorbance; --- Linear curve. A standard curve is divided into five sections according to concentration, absorbance difference absorbance difference between the highest and the lowest segment of the segment Ratio of not less than 0.7. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 746.3-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 746.3-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 746.3-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 746.3-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |