YS/T 514.5-2009 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 514.5-2009: Methods for chemical analysis of high titanium slag and rutile. Part 5: Determination of aluminium oxide content. EDTA titration YS/T 514.5: Historical versions
Basic dataStandard ID: YS/T 514.5-2009 (YS/T514.5-2009)Description (Translated English): Methods for chemical analysis of high titanium slag and rutile. Part 5: Determination of aluminium oxide content. EDTA titration Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H14;D42 Classification of International Standard: 77.120.90 Word Count Estimation: 6,673 Date of Issue: 2009-12-04 Date of Implementation: 2010-06-01 Older Standard (superseded by this standard): YS/T 514.8-2006 Regulation (derived from): MIIT [2009] No. 66 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the high titanium slag and rutile alumina content. This standard applies to high titanium slag and rutile in the determination of the amount of alumina, measuring range 0. 50% to 5. 00 % YS/T 514.5-2009: Methods for chemical analysis of high titanium slag and rutile. Part 5: Determination of aluminium oxide content. EDTA titration---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of high titanium slag and rutile.Part 5. Determination of aluminium oxide content.EDTA titration ICS 77.120.90 H14 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 514.8-2006 High titanium slag and rutile chemical analysis Part 5. Determination of the amount of alumina EDTA titration Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 514 "high titanium slag and rutile chemical analysis method" is divided into 10 parts. --- Part 1. Determination of titanium dioxide content of ammonium ferric sulfate titration; --- Part 2. Determination of total iron content of dichromate method; --- Part 3. Determination of sulfur content of high frequency infrared absorption method; --- Part 4. Determination of the amount of silica weighing method, the molybdenum blue spectrophotometric method; --- Part 5. aluminum oxide content - EDTA titration; --- Part 6. Determination of a manganese oxide content by flame atomic absorption spectrometry; --- Part 7. calcium oxide, magnesium oxide content - Flame atomic absorption spectrometry; --- Part 8. Determination of the amount of phosphorus antimony molybdenum blue spectrophotometric method; --- Part 9. calcium oxide, magnesium oxide, manganese oxide, phosphorus, chromium oxide and vanadium pentoxide content - Inductively coupled plasma Daughters emission spectrometry; --- Part 10. Determination of the amount of carbon frequency infrared absorption method. This section YS/T 514 Part 5. The partial replacement of YS/T 514.8-2006 "high titanium slag and rutile chemical analysis method EDTA volumetric method for the determination of aluminum oxide content." This portion of YS/T 514.8-2006 compared to the main changes are as follows. --- Dissolving a sample used in part to nickel-silver crucible crucible, the molten sample of sodium hydroxide to sodium hydroxide - sodium peroxide melt Financial sample; --- Will melt by the time 10min ~ 15min to 8min ~ 10min; --- The sample weight 0.4000g constant volume to 200mL sample weight 0.2000g volume to 100mL; --- Increasing the repeatability limit test as well as increased quality assurance and control provisions. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This section is responsible for drafting unit. Zunyi Titanium Co., Ltd., China Nonferrous Metals Industry Standards and Metrology Institute for Quality. Participated in the drafting of this section. Jinchuan Group Co., Ltd. Fushun Titanium. The main drafters of this section. Zhang Jinjie, Yu Jiahua, Marcion, Yu Shengjie, Zhuang Jun, Ma Yuping. This part of the standard replaces the previous editions are. --- GB/T 4102.8-1983; --- YS/T 514.8-2006. High titanium slag and rutile chemical analysis Part 5. Determination of the amount of alumina EDTA titration1 ScopeYS/T 514 This part provides high titanium slag and rutile alumina contents. This section applies to high titanium slag and rutile measured in the amount of alumina, the measurement range of 0.50% to 5.00%.2 Method summarySample with molten sodium hydroxide, dilute hydrochloric acid leaching. Hexamethylenetetramine precipitation of aluminum, titanium and iron, and magnesium, calcium and manganese and other elements separated and removed. The precipitate ashed low temperature, then sodium hydroxide melting, hot water leaching. Titanium and other elements are separated and removed. Pipette part of the test solution, the weak acid solution, Addition of excess EDTA complexed aluminum. At about pH6.0, xylenol orange as indicator, with zinc standard solution titration of excess EDTA. However After substitution with sodium fluoride complexes of EDTA, then zinc standard solution titration, thus determined amount of alumina. Tin content less than 0.2mg, chromium content of less than 1mg, vanadium content is less than 0.05mg does not affect the determination. When V is greater than 0.05mg, sulfuric acid Ferrous ammonium eliminate interference.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 Sodium hydroxide (excellent pure). 3.2 sodium peroxide. 3.3 ethanol. 3.4 Ammonia (ρ about 0.90g/mL). Ammonia 3.5 (1 + 1). 3.6 HCl (1 + 1). 3.7 hexamethylenetetramine solution (250g/L). Ammonium chloride solution was washed with 3.8 (20g/L). Each wash solution was added 100mL of 1 to 2 drops of ammonia (3.5). 3.9 ferrous ammonium sulfate solution (1g/L). The time is now equipped with. 3.10 disodium ethylenediamine tetraacetate (EDTA) solution (0.02mol/L). Weigh 3.72g disodium edetate (Na2C10H16O8N2 · 2H2O), was dissolved in 1000mL of water, and mix. 3.11 methyl orange solution (1g/L). 3.12 XO solution (2g/L). Store in a brown bottle, effective within a week. 3.13 sodium fluoride solution (40g/L). 3.14 acetic acid - ammonium acetate buffer solution (pH6.0 ± 0.2). Weigh 300g ammonium acetate were dissolved in 500mL water, filtered, added 12.3mL Glacial acetic acid diluted with water to 1000mL, and mix. (With a pH meter calibration). 3.15 Zinc Standard Solution (0.01000mol/L). Weigh 1.6276g of zinc oxide (spectroscopically pure), placed in 300mL beaker with water Wetting, was added 20mL of hydrochloric acid (3.6), was slowly dissolved by heating, and evaporated to a volume of about 3mL ~ 5mL, moved 2000mL volumetric flask Added (2-3) drops of methyl orange solution (3.11), was slowly dropping ammonia (3.5) until the solution was yellow, then dropping hydrochloric acid (3.6) until the solution was red Color and excess (5-6) drops, dilute with water to volume, and mix. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 514.5-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 514.5-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 514.5-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 514.5-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 514.5-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 514.5-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |