YS/T 514.1-2009 PDF EnglishUS$150.00 · In stock · Download in 9 seconds
YS/T 514.1-2009: Method for chemical analysis of high-titanium slag and rutile. Part 1: Determination of titanium dioxide content. Ferric ammonium sulfate titration Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid YS/T 514.1: Historical versions
Similar standardsYS/T 514.1-2009: Method for chemical analysis of high-titanium slag and rutile. Part 1: Determination of titanium dioxide content. Ferric ammonium sulfate titration---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST514.1-2009 YS NON-FERROUS METAL INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.90 H 14 Replacing YS/T 514.1-2006 Methods for chemical analysis of high-titanium slag and rutile - Part 1: Determination of titanium dioxide content - Ferric ammonium sulfate titration ISSUED ON: DECEMBER 04, 2009 IMPLEMENTED ON: JUNE 01, 2010 Issued by: Ministry of Industry and Information Technology of the People's Republic of China Table of ContentsForeword ... 3 1 Scope ... 5 2 Method summary ... 5 3 Reagents ... 5 4 Specimen ... 7 5 Analysis steps ... 7 6 Calculation of analysis results ... 8 7 Precision ... 8 8 Quality assurance and control ... 9ForewordYS/T 514 " Methods for chemical analysis of high-titanium slag and rutile" consists of the following 10 parts: - Part 1: Determination of titanium dioxide content - Ferric ammonium sulfate titration; - Part 2: Determination of total iron content - Potassium dichromate titration; - Part 3: Determination of sulfur content - High frequency infrared absorption method; - Part 4: Determination of silicon dioxide content - Gravimetric analysis and molybdenum blue spectrophotometry; - Part 5: Determination of aluminium oxide content - EDTA titration; - Part 6: Determination of manganese monoxide content - Flame atomic absorption spectrometry; - Part 7: Determination of calcium oxide and magnesium oxide content - Flame atomic absorption spectrometry; - Part 8: Determination of phosphorus content - Antimony molybdenum blue spectrophotometry; - Part 9: Determination of calcium oxide, magnesium oxide, manganese monoxide, phosphorus, chromic oxide and vanadium pentoxide; - Part 10: Determination of carbon content - High frequency infrared absorption method. This Part is Part 1 of YS/T 514. This Part replaces YS/T 514.1-2006 " Methods for chemical analysis of high- titanium slag and rutile The ammonium ferric sulfate volumetric method for the determination of titanium dioxide content". Compared with YS/T 514.1-2006, the main changes in this Part are as follows: - the added sodium peroxide does not change, but the amount added in advance is adjusted from 2g to 3g; adjusted the amount of coverage on the test material from 2g to 1g; - adjusted the sample weight from 0.2000g to 0.1000g; - added regulations on the allowable number of interfering elements such as Methods for chemical analysis of high-titanium slag and rutile - Part 1: Determination of titanium dioxide content - Ferric ammonium sulfate titration1 ScopeThis Part of YS/T 514 specifies the determination of titanium dioxide content in high titanium slag, rutile. This Part is applicable to the determination of titanium dioxide content in high titanium slag, rutile. The determination range: ≥70%. This Part is applicable to the determination of titanium dioxide amount in the test solution of which the content of chromium and vanadium is not more than 3mg, the content of molybdenum and tungsten is not more than 2mg, and the content of tin and copper is not more than 1mg.2 Method summaryThe test material is melted with sodium peroxide. Use water to leach. In sulfuric acid and hydrochloric acid medium, use aluminum foil to reduce titanium (IV) to (III) valence. Under the protection of carbon dioxide gas, use ammonium thiocyanate solution as indicator. Use ferric ammonium sulfate standard titration solution to titrate.3 ReagentsUnless otherwise specified, it shall only use the confirmed analytically-pure reagents AND distilled water or deionized water or equivalent-pure water. 3.1 Sodium peroxide. 3.2 Sodium bicarbonate. 3.3 Titanium dioxide (mass fraction ≥99.99%). 3.4 Aluminum foil (mass fraction ≥99.5%): Cut 1g of aluminum foil into a rectangle with a length of 3cm~4cm and a width of about 1cm. 3.5 Hydrochloric acid (ρ1.19g/mL). 0.9999 - The purity of titanium dioxide (3.3). If the range exceeds 0.10mL, it shall be re-calibrated.4 Specimen4.1 The particle size of the sample shall not be greater than 90μm. 4.2 The specimen needs to be pre-baked at 105°C~110°C for 2h. Place in a desiccator. Cool to room temperature.5 Analysis steps5.1 Test material Weigh 0.1g of specimen, to the nearest of 0.0001g. 5.2 Number of determinations Make parallel determinations of 3 test materials. Take the average value. 5.3 Blank test Do a blank test with test material. 5.4 Determination 5.4.1 Place the test material in a 30mL corundum crucible that has been pre- filled with 3g of sodium peroxide (3.1). Cover with 1g of sodium peroxide (3.1). Put on the crucible lid. Leave a gap. Bake on the electric stove until the flux is browned. Then put the crucible in a high temperature furnace. Melt at 750°C~800°C for 4min~6min. Take it out and cool. 5.4.2 Use filter paper to wipe the outer wall of the crucible. Put the crucible lid in a 300mL beaker. Add 50mL~60mL of water. Cover with watch glass. Heat and leach the melt. Remove and cool for a while. Slowly add 30mL of sulfuric acid (3.7) and 30mL of hydrochloric acid (3.5) along the wall of the cup. Heat to dissolve all the melt. Remove. Use hydrochloric acid (3.6) to wash the crucible and lid. 5.4.3 Transfer the solution into a 500mL Erlenmeyer flask. Add hydrochloric acid (3.6) to make the volume about 150mL. Heat for a while. Remove. Add 2g of aluminum foil in portions (3.4). Shake it from time to time. After most of the aluminum foil is dissolved, stopper the mouth of the bottle with a Geistlich funnel containing an appropriate amount of saturated sodium bicarbonate solution (3.8). Heat it on a low-temperature electric stove until the aluminum foil is ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of YS/T 514.1-2009 be delivered?Answer: The full copy PDF of English version of YS/T 514.1-2009 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of YS/T 514.1-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 514.1-2009_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YS/T 514.1-2009 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.Question 5: Should I purchase the latest version YS/T 514.1-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 514.1-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.How to buy and download a true PDF of English version of YS/T 514.1-2009?A step-by-step guide to download PDF of YS/T 514.1-2009_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "YS/T 514.1-2009". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |