SN/T 5237-2020 English PDFUS$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 5237-2020: (Import and export textiles. Determination of extractable heavy metals. Inductively coupled plasma mass spectrometry) Status: Valid
Basic dataStandard ID: SN/T 5237-2020 (SN/T5237-2020)Description (Translated English): (Import and export textiles. Determination of extractable heavy metals. Inductively coupled plasma mass spectrometry) Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: W04 Classification of International Standard: 59.080.01 Word Count Estimation: 7,721 Date of Issue: 2020-08-27 Date of Implementation: 2021-03-01 Regulation (derived from): General Administration of Customs Announcement No. 98 [2020] Issuing agency(ies): General Administration of Customs SN/T 5237-2020: (Import and export textiles. Determination of extractable heavy metals. Inductively coupled plasma mass spectrometry)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Textiles for import and export-Determination of extractable heavy metals- Inductively coupled plasma mass spectrometry method The People's Republic of China Entry-Exit Inspection and Quarantine Industry Standards Issued by the General Administration of Customs of the People's Republic of China 2020-08-27 release 2021-03-01 implementation Import and export textiles. Determination of extractable heavy metals. Inductively coupled plasma mass spectrometry ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed and managed by the General Administration of Customs of the People's Republic of China. This standard was drafted by. Weifang Customs of the People's Republic of China/Weifang Product Quality Inspection Institute. The main drafters of this standard. Zhang Jinling, Wang Liangliang, Ding Kuiying, Tian Guoning, Li Kai, Liu Dongxia, Sun Jun, Guo Liqiang. Determination of extractable heavy metals in textiles for import and export Inductively coupled plasma mass spectrometry Warning-personnel using this standard should have practical experience in formal laboratory work. This standard does not point out all possible safety issues question. The user is responsible for taking appropriate safety and health measures and ensuring compliance with the conditions stipulated by relevant national laws and regulations.1 ScopeThis standard specifies the use of inductively coupled plasma mass spectrometer (ICP-MS) to extract heavy metals such as lead (Pb) and cadmium in textiles. (Cd), Chromium (Cr), Arsenic (As), Copper (Cu), Antimony (Sb), Nickel (Ni), Cobalt (Co), Mercury (Hg) 9 simultaneous determination method. This standard applies to the determination of extractable heavy metals in various textile materials and their products.2 Normative referencesThe following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document. GB/T 602 Preparation of standard solutions for impurity determination of chemical reagents GB/T 3922 Textile color fastness test Color fastness to perspiration GB/T 6682 Analytical laboratory water specifications and experimental methods3 PrincipleThe sample was extracted with artificial acid sweat, filtered, and measured with an inductively coupled plasma mass spectrometer. Qualitative by element specific mass number Analysis, quantitative analysis with internal standard method.4 Reagents and materialsUnless otherwise specified, all reagents used are pure superior grade, and the experimental water is secondary water that meets the requirements of GB/T 6682. 4.1 Potassium dichromate. 4.2 Hydrochloric acid. The mass concentration is 36%~38%. 4.3 Nitric acid. The mass concentration is 65%~68%. 4.4 2% hydrochloric acid solution (volume concentration). 4.5 1% nitric acid solution (volume concentration). 4.6 5% nitric acid solution (volume concentration). 4.7 20% nitric acid solution (volume concentration). 4.8 Nitric acid solution of potassium dichromate (0.5 g/L). Weigh 0.05 g of potassium dichromate (4.1) and dissolve in 100 mL of 5% nitric acid solution (4.6). 4.9 Acid sweat. Use the secondary water specified in GB/T 6682 to prepare acid sweat according to GB/T 3922, and use it now. 4.10 Lead, cadmium, chromium, arsenic, copper, antimony, nickel, cobalt, mercury standard stock solution (1000 mg/L). prepared according to GB/T 602 standard or Purchase certified reference materials directly. 4.11 Mixed standard working solution (10 mg/L). accurately pipette 0.5 mL standard stock solution of lead, cadmium, chromium, arsenic, copper, antimony, nickel, and cobalt. The solution (4.10) is placed in a 50 mL volumetric flask, and the volume is fixed with 5% nitric acid solution (4.6) to obtain a 10 mg/L mixed standard working solution. Store in the refrigerator away from light, and the validity period is 1 month. 4.12 Mercury standard working solution (10 mg/L). accurately pipette 0.5 mL of mercury standard stock solution (4.10) into a 50 m1 volumetric flask, use The nitric acid solution of potassium dichromate (4.8) is fixed to a volume of 10 mg/L mercury standard working solution, and it is stored in a refrigerator at 4 ℃ and protected from light. The validity period is 2 years. 4.13 Internal standard stock solution (100 mg/L). Prepare according to GB/T 602 standard or directly purchase certified reference materials, the internal standard of each analysis element For standard elements, see Table A.2. 4.14 Mixed internal standard working solution (1 mg/L). respectively take 0.5 mL internal standard stock solution (4.13) in a 50 mL volumetric flask, and use 1% The volume of nitric acid solution (4.5) was fixed to obtain a mixed internal standard working solution of 1 mg/L. 4.15 Argon gas. purity ≥ 99.999%. 4.16 Helium. purity ≥ 99.999%.5 Apparatus and equipment5.1 Inductively coupled plasma mass spectrometer (ICP-MS). 5.2 Analytical balance. Sensitivity is 0.01 g and 0.1 mg. 5.3 Conical flask with stopper. 150 mL. Note. Before use, soak in 20% nitric acid solution overnight, rinse with water, and finally rinse with water for more than three times and dry. 5.4 Constant temperature water bath oscillator. It can be controlled at a constant temperature (37±2)°C, and the oscillation frequency is 60 times/min. 5.5 Water filter membrane. 0.45 μm.6 Test procedure6.1 Preparation of extraction sample solution Take a representative sample, cut it into small pieces below 5 mm×5 mm, mix well, weigh 4 g sample, accurate to 0.01 g, and place it in a stopper. In the triangular flask (5.3), add 80 mL of acidic sweat (4.9), soak the fiber fully, and place it in a constant temperature water bath shaker (5.4). After shaking for (60±5) min, take it out, let stand and cool to room temperature, filter through membrane (5.5), add 0.1 mL per 10 mL of filtrate for mercury measurement Hydrochloric acid (4.2), add 0.05 mL of nitric acid (4.3) for every 10 mL of filtrate to test other elements, as the test solution. 6.2 Blank test Carry out a blank test with the same product. 6.3 Preparation of standard working curve Take a certain amount of lead, cadmium, chromium, arsenic, copper, antimony, nickel, and cobalt mixed standard working solution (4.11), use 1% nitric acid solution (4.5) Prepare a series of standard working solutions by diluting step by step. Take a certain amount of mercury standard working solution (4.12) and dilute with 2% hydrochloric acid solution (4.4) step by step Prepare a series of standard working solutions (the highest point does not exceed 5 μg/L). 6.4 Determination Refer to Table A.1 to optimize the parameters of the instrument conditions. The mass number and integration time of the analysis elements are shown in Table A.2. Solution, blank solution and sample solution. If the measurement result exceeds the range of the standard working curve, the test solution needs to be diluted before proceeding Determination.7 Result calculationThe content of each extractable heavy metal in the sample is calculated according to formula (1). Xi - the content of metal element i in the sample, in milligrams per kilogram (mg/kg); Ci-the concentration of metal element i in the sample solution, in micrograms per liter (μg/L); Ci0-the concentration of metal element i in the blank solution, in micrograms per liter (μg/L); V-the volume of the sample solution, the unit is milliliters (mL); F-dilution factor; m-the mass of the sample, in grams (g). The calculation result retains two significant digits.8 Low limit of determinationThe lower limit of this method is shown in Table 1. Note. The detection limits of different instruments will vary, and the lower limit of this method is for reference only.9 PrecisionIn the same laboratory, the same operator uses the same equipment and according to the same test method to continuously perform the same test on the same object. Independent test, the relative standard deviation of the two independent test results obtained is not more than 10%. With the arithmetic greater than these two measured values It is assumed that 10% of the average value does not exceed 5%.Appendix A(Informative appendix) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 5237-2020_English be delivered?Answer: Upon your order, we will start to translate SN/T 5237-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 5237-2020_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 5237-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |