SN/T 4026-2014 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 4026-2014: Determination of aluminium、iron、calcium、magnesium、sodium、potassium、titanium、lead、cadmium、silicon、zinc、copper in the glass - Inductively coupled plasma atomic emission spectrometry Status: Valid
Basic dataStandard ID: SN/T 4026-2014 (SN/T4026-2014)Description (Translated English): Determination of aluminium��iron��calcium��magnesium��sodium��potassium��titanium��lead��cadmium��silicon��zinc��copper in the glass - Inductively coupled plasma atomic emission spectrometry Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: Y22 Classification of International Standard: 81.040.30 Word Count Estimation: 8,845 Date of Issue: 12/1/2014 Date of Implementation: 5/1/2015 Quoted Standard: GB/T 1347; GB/T 6682 Regulation (derived from): State-Quality-Inspection-accreditation [2014] 614 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the daily glass products, aluminum, iron, calcium, magnesium, sodium, potassium, titanium, lead, cadmium, silicon, zinc, copper plasma emission spectrometry (ICP) spectrometry. This standard applies to the determination of the dail SN/T 4026-2014: Determination of aluminium、iron、calcium、magnesium、sodium、potassium、titanium、lead、cadmium、silicon、zinc、copper in the glass - Inductively coupled plasma atomic emission spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. (Daily glass products, aluminum, measuring inductance iron, calcium, magnesium, sodium, potassium, titanium, lead, cadmium, silicon, zinc, copper, coupled plasma atomic emission spectrometry) People's Republic of China Entry-Exit Inspection and Quarantine Standards Daily glass products, aluminum, iron, calcium, magnesium, sodium, Determination of potassium, titanium, lead, cadmium, silicon, zinc, copper Inductively coupled plasma atomic emission spectrometry Determinationofaluminium, iron, calcium, magnesium, sodium, potassium, titanium, lead, cadmium, silicon, zinc, copperintheglass-Inductivelycoupled Issued on. 2014-11-19 2015-05-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Shandong CIQ. The main drafters. Zhang Miao, Zhang Li, Xiang Haibo, Xuhong Min, Xu Jian, Sun meter Chan, Tao Lin, Miao your East, Wang Yue, Wang Kegang. Daily glass products, aluminum, iron, calcium, magnesium, sodium, Determination of potassium, titanium, lead, cadmium, silicon, zinc, copper Inductively coupled plasma atomic emission spectrometry1 ScopeThis standard specifies the daily glass products, aluminum, iron, calcium, magnesium, sodium, potassium, titanium, lead, cadmium, silicon, zinc, copper plasma emission spectrometry (ICP) spectrometry. This standard applies to household products as well as glass with a similar product of aluminum, iron, calcium, magnesium, sodium, potassium, titanium, lead, cadmium, silicon, zinc, copper and other yuan Determination of pigment content. Determination of the range in Table 1. Table 1 Element Measuring range/(g/kg) Al 0.025 ~ 76.12 Fe 0.0021 ~ 8.52 Ca 0.0035 ~ 118.69 Mg 0.018 ~ 33.26 Na 0.024 ~ 115.16 K 0.060 ~ 233.44 Ti 0.0025 ~ 2.13 Pb 0.028 ~ 0.91 Cd 0.0085 ~ 0.15 Si 0.018 ~ 334.02 Zn 0.0053 ~ 3.16 Cu 0.0026 ~ 0.0852 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 1347 soda-lime-silica glass chemical analysis Laboratory use - Specification and test methods GB/T 6682 Analysis3 Method summaryAfter sample digestion using inductively coupled plasma emission spectrometer daily glass products, aluminum, iron, calcium, magnesium, sodium, potassium, titanium, lead, Cd, Si, Zn, Cu content. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 4026-2014_English be delivered?Answer: Upon your order, we will start to translate SN/T 4026-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 4026-2014_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 4026-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |