SN/T 3915-2014 English PDFUS$159.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 3915-2014: Determination of magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium in aluminum alloy. X ray fluorescence spectrometry Status: Valid
Basic dataStandard ID: SN/T 3915-2014 (SN/T3915-2014)Description (Translated English): Determination of magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium in aluminum alloy. X ray fluorescence spectrometry Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: H12 Classification of International Standard: 77.150.10 Word Count Estimation: 6,611 Date of Issue: 4/9/2014 Date of Implementation: 11/1/2014 Quoted Standard: GB/T 16597 Regulation (derived from): State inspection certification (2014) 210 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the method for determination of aluminum and aluminum alloy magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium content of the X-ray fluorescence spectrometry. This standard applies to the determination of SN/T 3915-2014: Determination of magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium in aluminum alloy. X ray fluorescence spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium in aluminum alloy. X ray fluorescence spectrometry People's Republic of China Entry-Exit Inspection and Quarantine Standards Aluminum and aluminum alloy magnesium, silicon, titanium, manganese, iron, nickel, copper, Zinc, gallium measuring X-ray fluorescence spectrometry Determinationofmagnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, Issued on. 2014-04-09 2014-11-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released ForewordThis standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Qinghai Exit Inspection and Quarantine. The main drafters of this standard. Dai Dayong, Li communication Guoqing Bin, Zhang Rong, Li Li. Aluminum and aluminum alloy magnesium, silicon, titanium, manganese, iron, nickel, copper, Zinc, gallium measuring X-ray fluorescence spectrometry1 ScopeThis standard specifies the method for determination of aluminum and aluminum alloy magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium content of the X-ray fluorescence spectrometry. This standard applies to the determination of aluminum and aluminum alloy magnesium, silicon, titanium, manganese, iron, nickel, copper, zinc, gallium in the measurement range shown in Table 1. Table 1 Method of measuring range% Element measurement range Si 0.0084 ~ 1.18 Fe 0.0064 ~ 1.20 Cu 0.0041 ~ 0.093 Mn 0.00025 ~ 0.205 Mg 0.0027 ~ 0.143 Ni 0.00040 ~ 0.114 Zn 0.0030 ~ 0.188 Ti 0.0010 ~ 0.086 Ga 0.0034 ~ 0.0502 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 16597 metallurgical product analysis X-ray Fluorescence Spectrometry General3 Method summaryAnalysis of the sample surface processed into a smooth plane, under the selected instrument measurement conditions, the measurement sample analyte and the internal standard characteristic lines X-ray fluorescence intensity characteristic spectral lines of the elements aluminum, according to the spectral characteristics of the analyte and the internal standard elements aluminum characteristic lines of X-ray fluorescence The intensity ratio of the quantitative relationship between the analyte content with the appropriate choice of regression methods and mathematical correction mode, the calculated measured elements content.4 Reagents and materials4.1 Asian methane gas (10% methane, 90% argon). Aluminum and aluminum alloy 4.2 certified reference materials. spectrum with standard test block. Each element should be at least six standard samples, the content should be a certain room ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 3915-2014_English be delivered?Answer: Upon your order, we will start to translate SN/T 3915-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 3915-2014_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 3915-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |