SN/T 2763.1-2011 English PDFUS$289.00 ยท In stock  
  Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 2763.1-2011: Determination of multi-components in nickel laterite ores. Part 1: X-ray fluores cence spectrometric method Status: Valid 
 Basic dataStandard ID: SN/T 2763.1-2011 (SN/T2763.1-2011)Description (Translated English): Determination of multi-components in nickel laterite ores. Part 1: X-ray fluores cence spectrometric method Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: D40 Classification of International Standard: 73.060.99 Word Count Estimation: 11,195 Date of Issue: 2011-02-25 Date of Implementation: 2011-07-01 Quoted Standard: GB/T 16597 Regulation (derived from): ?AQSIQ-Inspection [2011] 90 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the wavelength dispersive X -ray fluorescence spectrometric method for multi-component nickel laterite ore. This section applies to the determination of nickel laterite in a variety of ingredients. Measuring range (mass fraction) are shown in Table l. SN/T 2763.1-2011: Determination of multi-components in nickel laterite ores. Part 1: X-ray fluores cence spectrometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of multi-components in nickel laterite ores.Part 1. X-ray fluores cence spectrometric method People's Republic of China Entry-Exit Inspection and Quarantine Standards Determination of nickel laterite ore more components Part 1. X-ray fluorescence spectrometry Part 1. X-rayfluorescencespectrometricmethod Issued on. 2011-02-25 2011-07-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released Foreword"Determination of nickel laterite ore more components" SN/T 2763 series of standards is divided into five parts. --- Part 1. X-ray fluorescence spectrometry --- Part 2. nickel, cobalt content by flame atomic absorption spectrometry --- Part 3. Determination of total iron content --- Part 4. Flame atomic copper, zinc, chromium absorption method --- Part 5. nickel, aluminum, chromium, magnesium, cobalt content was measured plasma emission spectrometry This section SN/T 2763 Part 1. This section drafted in accordance with GB/T 1.1-2009 given rules. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section was drafted by. People's Republic of China Ningbo Exit Inspection and Quarantine. The main drafters of this section. Zhang Jianbo, Chen Jianguo, forest edge, Lin Zhenxing, Hou Jianguo, Wang Qian. The first part of the Department of Inspection and Quarantine issued by industry standards. Determination of nickel laterite ore more components Part 1. X-ray fluorescence spectrometry1 ScopeThis section provides wavelength dispersive X-ray fluorescence spectrometric method more components of nickel laterite ore. This section applies to the determination of nickel laterite ore more components, measurement range (by mass) shown in Table 1. Table 1 laterite nickel ore in the measurement range of each component Component mass fraction range /% Al2O3 0.10 ~ 21.50 CaO 0.01 ~ 2.60 Cr2O3 0.01 ~ 4.20 Co 0.02 ~ 0.24 Fe 0.10 ~ 47.9 MgO 2.90 ~ 39.10 MnO 0.01 ~ 2.00 Ni 0.40 ~ 4.40 P 0.01 ~ 0.50 SiO2 0.50 ~ 59.50 TiO2 0.01 ~ 0.402 Normative referencesThe following documents for the application of this document is essential. For dated references, only the edition are not applicable to the present file. For undated references, the latest edition (including any amendments) applies to this document. GB/T 16597 metallurgical product analysis X-ray Fluorescence Spectrometry General3 Method summaryPowder samples with a suitable flux cast by a certain percentage to be suitable for sample fuse X-ray fluorescence spectrometer measurements. In selected Measuring the analyte sample sheet melting characteristic spectral lines of the instrument X-ray fluorescence intensity measurement conditions, calibration curve or equation meter Operator, and inter-element interference effect correction to obtain the content of analyte in the sample.4 Reagents and materialsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 2763.1-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 2763.1-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 2763.1-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 2763.1-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |