Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

SN/T 2498.1-2010 English PDF

US$139.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 2498.1-2010: Basic environmental testing procedures for import and export fireworks. Test Db: Damp heat, cyclic
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
SN/T 2498.1-2010139 Add to Cart 2 days Basic environmental testing procedures for import and export fireworks. Test Db: Damp heat, cyclic Valid

Similar standards

GB 19593   GB/T 18043   GB 11887   SN/T 2498.4   SN/T 2498.3   SN/T 2498.2   

Basic data

Standard ID: SN/T 2498.1-2010 (SN/T2498.1-2010)
Description (Translated English): Basic environmental testing procedures for import and export fireworks. Test Db: Damp heat, cyclic
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: Y88
Classification of International Standard: 71.100.30
Word Count Estimation: 5,533
Date of Issue: 2010-03-02
Date of Implementation: 2010-09-16
Regulation (derived from): National Quality Inspection (2010) 98; industry standard filing Notice 2010 No. 5 (No. 125 overall)
Issuing agency(ies): General Administration of Customs
Summary: This standard specifies the damp heat test fireworks post test procedures, severities and right chamber (chamber) of the basic requirements. This standard applies to determine the import and export of fireworks in the temperature cycling, the product surface condensation of the hot and humid conditions of use and storage adaptability.

SN/T 2498.1-2010: Basic environmental testing procedures for import and export fireworks. Test Db: Damp heat, cyclic


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Basic environmental testing procedures for import and export fireworks.Test Db. Damp heat, cyclic Exit inspection and quarantine industry standard book People's Republic of China Importers Pyrotechnic products Basic environmental testing norms Test D Chou. alternating hot and humid test methods Issued on. 2010-03-02 2010-09-16 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Foreword

SN/T 2498 "Importers Pyrotechnic products environmental testing norms" standard series is divided into two parts. --- Test Db. Damp heat test, cyclic; --- Test Ed. Free fall. This section SN/T 2498 Part 1. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section is responsible for drafting unit. People's Republic of China Tianjin Entry-Exit-Entry Inspection and Hunan People's Republic of China Quarantine Bureau. The main drafters of this section. Li Xue Yang, Wangli Bing, Zhao Haolibao to clean snow, Liu Rui, Han Wei. The first part of the Department of Inspection and Quarantine issued by industry standards. Importers Pyrotechnic products Basic environmental testing norms Test D Chou. alternating hot and humid test methods

1 Scope

This section SN/T 2498 specifies the test procedures fireworks alternating hot and humid test, and the severity of the basic chamber (chamber) Requirements. Under this section applies to determine the import and export of fireworks in the temperature cycling, the product surface condensation of humid conditions of use and storage Adaptability. 2 chamber (chamber) requirements It should be fitted to monitor temperature and humidity conditions inside the sensor 2.1 workspace. Temperature 2.2 Operating space should be able to cycle vary between 25 ℃ ± 3 ℃ with the selected temperature; rate of temperature change and temperature tolerance can Meet the test requirements. RH 2.3 workspace can meet the test requirements. 2.4 Temperature and humidity work space should be uniform, and may be consistent with the conditions of temperature and humidity at the sensor. 2.5 Test Equipment radiant heat of the heating element should not be directly on the test specimen. 2.6 produces humidity plus wet direct contact with water in the test resistivity of the water should remain lower than 500Ω · m. 2.7 Condensate discharge should continue to work outdoors without purification treatment may not be used again. 2.8 Condensate chamber (chamber) inner wall and the top should not drip on the test sample. And electrical properties of test samples 2.9 load should not significantly affect the temperature and humidity conditions in the workspace.

3 severities

3.1 Test severity determined by a combination of high temperature and other temperature and the number of test cycles. 3.2 Select the severity from the following combinations. a) high temperature Temperature. 40 ℃ Test cycle. 2d, 6d, 12d, 21d, 56d. b) temperature temperature. 55 ℃ Test cycle. 1d, 2d, 6d

4 Test Procedure

4.1 Initial Detection Accordance with the regulations about labels, visual inspection of the test sample. 4.2 Test Conditions 4.2.1 The test sample was placed in accordance with its normal placement within the chamber (chamber) of the workspace. If the test sample is placed in a special way, Required with mounting bracket, the thermal conductivity of the sample holder should be as low as possible, so that the test sample is actually insulated. 4.2.2 at a temperature of 25 ℃ ± 3 ℃, relative humidity of 45% to 75% under the conditions of the test sample to reach the temperature steady. After that, The relative humidity within 1h working space is increased to not less than 95%. 4.2.3 so that the temperature inside the working space within 24h cycling. a) heating stage. Within 3h ± 0.5h, continuously raised the standards prescribed temperature value of the temperature of the workspace, the heating rate should be
......
Image