SN/T 2075-2008 English PDFUS$259.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 2075-2008: Codes of surveillance for enterohemorrhagic Escherichia coli O157: H7 at entry-exit port Status: Valid
Basic dataStandard ID: SN/T 2075-2008 (SN/T2075-2008)Description (Translated English): Codes of surveillance for enterohemorrhagic Escherichia coli O157: H7 at entry-exit port Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: C62 Word Count Estimation: 10,155 Date of Issue: 2008-04-29 Date of Implementation: 2008-11-01 Quoted Standard: SN/T 1215; SN/T 1861-2007 Regulation (derived from): Industry standard filing Notice 2008 No. 7 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the ports of entry EHEC O157: H7 infection surveillance objects, monitoring content and methods, results to determine, disease reporting, disease treatment and monitoring reports. This standard applies to ports of entry EHEC O157: H7 infection surveillance. SN/T 2075-2008: Codes of surveillance for enterohemorrhagic Escherichia coli O157: H7 at entry-exit port---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Codes of surveillance for enterohemorrhagic Escherichia coli O157. H7 at entry-exit port Exit inspection and quarantine industry standard book People's Republic of China Ports of entry enterohemorrhagic E. Coli O157. H7 monitoring procedures Posted 2008-04-29 2008-11-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released ForewordAppendix A of this standard is a normative appendix, Appendix B and Appendix C are informative appendices. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Guangdong Entry Inspection and Quarantine Bureau, Dongguan People's Republic of China Entry-Exit Inspection and Quarantine Bureau. The main drafters of this standard. SHI Yong Xia Xing Lu Qin, Li Zuhai, Hong Ye, Gobo rotation, Li Xiaobo, phase Dapeng, Huang Ji City, Cheng Kui. This standard is the first release of the entry-exit inspection and quarantine industry standards. Ports of entry EHEC O157. H7 monitoring procedures1 ScopeThis standard specifies the ports of entry EHEC O157. H7 infection in the object, content and methods of monitoring results sentenced Off disease reporting, disease treatment and monitoring reports. This standard applies for crossing EHEC O157. H7 infection monitoring.2 Normative referencesThe following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard. SN/T 1215 exit into the passenger train de-worming procedure SN/T 1861-2007 ports of entry to public health emergencies emergency procedures General EHEC O157. H7 infection diarrhea monitoring program (Trial) (Ministry of Health) National vector biological monitoring program (Trial) (Ministry of Health)3 Terms and DefinitionsThe following terms and definitions apply to this standard. 3.1 People can cause bloody diarrhea and colitis group of Escherichia coli to O157. H7 serotype represented by strain. Enterohemorrhagic Typical clinical manifestations of E. coli infection is mild diarrhea, hemorrhagic colitis (HC), hemolytic-uremic syndrome (HUS), thrombotic Thrombocytopenic purpura (TTP) and the like. Wherein HUS dangerous course, it could easily lead to acute renal failure and death.4 of the object4.1 ports of entry immigration officers, transport workers, border control points and public places food production and operation service industry employees. 4.2 the host animal and insect vectors. 4.3 entry and exit points of the range of water, food.5 monitors content5.1 Monitoring population Focus on monitoring immigration officers, transport workers, border control points and public places food production and operation of the service industry employees diarrhea Patients and carriers. 5.2 Monitoring Animals Entry and exit points to monitor animal species range poultry and livestock mainly cattle, sheep, chickens, pigs as the main monitor animals in large intestinal bleeding E. coli O157. H7 infection in endemic areas to provide export products, farms, dairy farms should be included within the scope of monitoring. 5.3 Monitoring insect vector Spread of EHEC in the monitoring ports of entry O157. H7 infection diarrhea medical vectors distribution and colonization love ...... |