Home   Cart   Quotation   Policy   About-Us
www.ChineseStandard.net
SEARCH

SN/T 1754-2012 English PDF

US$469.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 1754-2012: Diagnosis standard and surveillance codes of human avian influenza at entry-exit port
Status: Valid

SN/T 1754: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
SN/T 1754-2012469 Add to Cart 3 days Diagnosis standard and surveillance codes of human avian influenza at entry-exit port Valid
SN/T 1754-2006839 Add to Cart 6 days Ports of entry of human avian influenza diagnostic criteria and monitoring procedures Obsolete

Similar standards

GBZ 57   GB/T 31989   SN/T 5800.2   SN/T 5800.4   SN/T 5800.1   

Basic data

Standard ID: SN/T 1754-2012 (SN/T1754-2012)
Description (Translated English): Diagnosis standard and surveillance codes of human avian influenza at entry-exit port
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: C62
Classification of International Standard: 11.220; 13
Word Count Estimation: 18,120
Older Standard (superseded by this standard): SN/T 1754-2006
Quoted Standard: GB 15994-1995; GB 19082; SN/T 2093; SN/T 2354; WS 284-2008
Regulation (derived from): National Quality Inspection (2012) 237; industry standard filing Notice 2012 No. 9 (No. 153 overall)
Issuing agency(ies): General Administration of Customs
Summary: This standard specifies the port of entry and exit of people infected with highly pathogenic avian influenza diagnostic criteria and the Port of human infection with highly pathogenic avian influenza monitoring requirements, object, content and methods, r

SN/T 1754-2012: Diagnosis standard and surveillance codes of human avian influenza at entry-exit port


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Diagnosis standard and surveillance codes of human avian influenza at entry-exit port People's Republic of China Entry - Exit Inspection and Quarantine Industry Standard Replacing SN/T 1754-2006 Diagnostic criteria for human avian influenza at entry and exit Monitoring procedures 2012-05-07 release Implementation of.2012-11-16 People's Republic of China State Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces SN/T 1754-2006 "Diagnostic standard and monitoring procedure for human avian influenza at entry and exit points". Compared with SN/T 1754-2006, the main technical changes are as follows. --- increase the "human infection with highly pathogenic avian influenza diagnostic criteria" (WS284-2008), "entry and exit of human avian influenza infection transport health (SN/T 2093-2008), "Procedures for the disinfection of highly pathogenic avian influenza at border crossings" (SN/T 2354-2009) Normative reference documents; - to modify the original standard in the "3 terms and definitions" in the "avian flu" as "human avian influenza"; --- increase the original standard "7.3.1 monitoring method" in the temperature monitoring content; --- modify the original standard "9.4 laboratory testing" content; --- to modify the original standard "10 into the territory of the diagnosis of human avian influenza" content; --- modify the original standard "11.2.2 spot disinfection treatment" content; --- modify the original standard "12.1 found in the report of the case of monitoring" 8h for 12h; --- modify the original standard "12.2.2 report time limit" in 2h for 1h; --- delete the original standard in Appendix D, Appendix F content. This standard is proposed and approved by the National Certification and Accreditation Administration Committee. The drafting unit of this standard. Tianjin Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China, Shandong Entry-Exit Inspection and Quarantine of the People's Republic of China Bureau of Sichuan Entry - Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. Tan Xuliang, Wang Fengxin, Zhou Junye, Zuo Feng, Feng Guanzheng, Jiang Luming, Bu Honglei, Tan Ling, Yang Yu, Zhou Jungang. This standard replaced the previous version of the standard release. --- SN/T 1754-2006. Diagnostic criteria for human avian influenza at entry and exit Monitoring procedures

1 Scope

This standard specifies the diagnostic criteria for the infection of highly pathogenic avian influenza among people entering and leaving the country and the surveillance of highly pathogenic avian influenza in port people Requirements, objects, content and methods, outcome determination, disposal and precautionary measures. This standard is applicable to the monitoring and diagnosis of highly pathogenic avian influenza in people infected with the territory.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. Diagnostic criteria and principles of management of influenza GB 15994-1995 Technical requirements for disposable protective clothing for medical use GB 19082 Code of Hygienic Treatment for Infected Traffic in Avian Influenza Disinfection procedures for highly pathogenic avian influenza in border crossings Diagnostic criteria for infection of highly pathogenic avian influenza in people infected with WS284-2008

3 terms and definitions

The following terms and definitions apply to this document. 3.1 Human avianinfluenza By some of the avian influenza virus virus in some subtypes caused by the respiratory system to severe systemic sepsis and other symptoms of acute infectious disease.

4 requirements

Entry and exit port implementation of human infection with highly pathogenic avian influenza surveillance requirements. - a monitoring team consisting of disease monitoring expertise and operational skills to establish a monitoring system; --- According to the characteristics of avian influenza epidemic design monitoring program, a clear purpose of monitoring, unified monitoring methods and personal protection; --- monitoring information should be collected in a timely manner, accurate and complete, unified management; - Effect evaluation and experience summary of monitoring process, monitoring results, precautionary measures, and hygiene measures.

5 objects

People who are infected with highly pathogenic avian influenza are involved in. --- from the report of avian influenza epidemic areas of entry and exit personnel; - the presence of avian influenza in the location of the port, and the contact with the sick bird suspects at the exit port staff or with the birds are closely
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 1754-2012_English be delivered?

Answer: Upon your order, we will start to translate SN/T 1754-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 1754-2012_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 1754-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version SN/T 1754-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 1754-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.