SN/T 0639-2013_English: PDF (SN/T0639-2013)
Standard ID | USD | BUY PDF | Lead-Days | Standard Title (Description) | Status |
SN/T 0639-2013 | 549 |
Add to Cart
|
4 days
|
Determination of linuron and its metabolite residues in meat and meat products for export. HPLC-MS/MS method
| Valid |
SN 0639-1997 | 519 |
Add to Cart
|
4 days
|
Method for the determination of linuron residues in meats and meat products for export
| Obsolete |
Standard ID | SN/T 0639-2013 (SN/T0639-2013) | Description (Translated English) | Determination of linuron and its metabolite residues in meat and meat products for export. HPLC-MS/MS method | Sector / Industry | Commodity Inspection Standard (Recommended) | Classification of Chinese Standard | X22 | Classification of International Standard | 67.120 | Word Count Estimation | 21,244 | Older Standard (superseded by this standard) | SN 0639-1997 | Quoted Standard | GB/T 6682 | Issuing agency(ies) | General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China | Summary | This standard specifies the meat and meat products linuron and its metabolites (3, 4 - dichloro-aniline) Determination of residues. This standard applies to pork, kidney, liver, pork sausage, lunch meat sticks, sausages, meat and meat products linuron and |
SN/T 0639-2013
Determination of linuron and its metabolite residues in meat and meat products for export.HPLC-MS/MS method
People's Republic of China Entry-Exit Inspection and Quarantine Standards
Replacing SN 0639-1997
Exports of meat and meat products linuron and its metabolite
Detection of Residual
Liquid chromatography - mass spectrometry/mass spectrometry
HPLC-MS/MSmethod
Issued on. 2013-08-30
2014-03-01 implementation
People's Republic of China
The State Administration of Quality Supervision, Inspection and Quarantine released
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces SN 0639-1997 "export of meat and meat products linuron residues in."
This standard compared with SN 0639-1997, the main technical changes are as follows.
--- Change the standard name, increasing the measured metabolites;
--- Expanding the scope of application of the matrix;
--- Remove the sampling part;
--- Change to gas chromatography liquid chromatography - mass spectrometry/mass spectrometry, lower detection limit.
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Shanghai Entry-Exit Inspection and Quarantine Bureau.
The main drafters of this standard. Iraq male sea, Qu Li, Cao Chen, Guo Dehua, Deng Xiaojun, Zhu Jian, Sheng Yonggang, Yang Huiqin, including Ming.
This standard replaces the standards previously issued as follows.
--- SN 0693-1997.
Exports of meat and meat products linuron and its metabolite
Detection of Residual
Liquid chromatography - mass spectrometry/mass spectrometry
1 Scope
This standard specifies the method for determination of export meat and meat products linuron and its metabolites (3,4-dichloro-aniline) residues.
This standard applies to exports of pork, kidney, liver, pork sausage, luncheon meat, sausages, meat and meat products linuron and its metabolite
(3,4-dichloro-aniline) residual amount of liquid chromatography - mass spectrometry/mass spectrometry and confirmation.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
Laboratory use specifications and test methods GB/T 6682 Analysis
3 Method summary
Sample remaining linuron and its metabolite with acetone - acetonitrile extract, extract fat frozen at -18 ℃ refrigerator, extract mining
With Florisil column purification, liquid chromatography - mass spectrometry/mass spectrometry and validation, internal standard.
4 Reagents and materials
Unless otherwise specified, use the analytical reagent, the water is deionized water.
4.1 acetonitrile. HPLC fractions.
4.2 acetone. HPLC fractions.
4.3 hexane. HPLC fractions.
4.4 ether. HPLC fractions.
4.5 formic acid. pure class distinctions, ≥99%.
4.6 ammonium acetate.
4.7 acetone, acetonitrile (595, volume ratio). Measure 50mL and 950mL acetonitrile, acetone, and mix.
4.8 diethyl ether-hexane (19. volume ratio). Measure 100mL ether and 900mL hexane, and mix.
4.9 acetone and n-hexane (19. volume ratio). Measure 100mL acetone and 900mL hexane, and mix.
4.10 aqueous acetonitrile (11 volume). amount of 100mL of acetonitrile and 100mL of water, and mix.
4.11 anhydrous sodium. 650 ℃ burning 4h, stored in a sealed container in the back.
4.12 containing 5mmol L ammonium acetate and water/0.1% formic acid. Weigh 385.4mg of ammonium acetate and 1mL acid dissolved in pure water
And the volume to 1L.
4.13 Standard substances. linuron (Linuron, CAS number. 330-55-2), linuron isotope internal standard (Linuron-D6), 3,4- dichloro-aniline
(3,4-Dichloroaniline, CAS number. 95-76-1); 3,4-dichloroaniline isotope internal standard (3,4-Dichloroaniline-2,6-D2), purity
......
|