LY/T 1330-2023 English PDFUS$419.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. LY/T 1330-2023: Antistatic wood-based moveable floor Status: Valid LY/T 1330: Historical versions
Basic dataStandard ID: LY/T 1330-2023 (LY/T1330-2023)Description (Translated English): Antistatic wood-based moveable floor Sector / Industry: Forestry Industry Standard (Recommended) Classification of Chinese Standard: B70 Classification of International Standard: 79.080 Word Count Estimation: 21,224 Date of Issue: 2023-06-19 Date of Implementation: 2023-11-01 Issuing agency(ies): State Forestry and Grassland Administration LY/T 1330-2023: Antistatic wood-based moveable floor---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.ICS 79.080 CCSB70 Forestry Industry Standard of the People's Republic of China Replace LY/T 1330-2011 Antistatic wooden raised floor Released on 2023-06-19 2023-11-01 Implementation The State Forestry and Grassland Administration issued ForewordThis document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1.Structure and drafting rules for standardization documents" Drafting. This document replaces LY/T 1330-2011 "Antistatic Wooden Raised Floor". Compared with LY/T 1330-2011, in addition to structural adjustments and In addition to editorial changes, the main technical changes are as follows. --- Changed the scope (see Chapter 1, Chapter 1 of the.2011 edition); --- Changed the definitions of "antistatic wooden raised floor", "system resistance", "concentrated load", "rated concentrated load" and "rolling load" (see 3.1, 3.2, 3.5, 3.6, 3.7, 3.1, 3.2, 3.6, 3.7, 3.8 of the.2011 version), delete "load point" (see 3.5 of the.2011 version); --- Added "Structure" (see Chapter 4); --- Changed the requirements for "net length deviation" and "thickness deviation" in "Requirements" (see Table 2, Table 1 of the.2011 edition); --- Changed the content of "Appearance Quality" in "Requirements" and added the appearance quality requirements of fasteners and support systems (see 5.2,.2011 Version 4.2); --- Changed the names of "wheel wear" and "electrical properties" in "physical and chemical properties" (see Table 3, Table 4, 6.4.2, 6.3.4,.2011 version of the table 2,5.2.6,5.2.10); --- Deleted "surface wear resistance", "castor wear resistance", "impact resistance", "concentrated load" and "rolling load" in "physical and chemical properties" (see.2011 edition Table 2) includes "surface wear resistance", "castor wear resistance", "impact resistance", "concentrated load" and "rolling load" in the "mechanical properties" "capable" (see 5.4); --- Added "support system load performance" and its test method, and included the relevant content in "mechanical properties" (see Table 4, 6.4.6); --- Deleted "combustion performance" in "physical and chemical properties", listed "combustion performance" independently, and changed the description of its requirements and test methods (See Table 2, 5.2.11 of 5.5, 6.5,.2011 edition); --- Added "Concentration limits of volatile organic compounds" and its test methods, and included relevant content in "Physical and chemical properties" (see Table 3,6.3.6); --- Added "appearance" and its inspection method (see 5.2, 6.2); --- Added requirements for physical and chemical properties test specimens (see Table 5); --- Deleted the requirements and test methods for "surface resistance to cold and hot cycles" (see 5.2.3 of the.2011 edition); --- Changed the test method of "water absorption thickness expansion rate" (see 6.3.2, 5.2.2 of the.2011 edition); --- Changed the test method of "surface contamination resistance" (see 6.3.3, 5.2.4 of the.2011 edition); --- Changed the test method of "antistatic performance" (see 6.3.4, 5.2.10 of the.2011 edition); --- Changed the test method of "formaldehyde emission" in "physical and chemical properties" (see 6.3.5, 5.2.12 of the.2011 edition); --- Deleted the "test environment" of "wear resistance of castors" (see 5.2.6.1 of the.2011 edition), and changed the castor wear resistance of castors. The hardness is (95 ± 5) (see 6.4.2.1, 5.2.6.1 of the.2011 edition); --- Changed the test method of "impact resistance" (see 6.4.3, 5.2.7 of the.2011 edition); --- Changed the description of the “concentrated load” test method (see 6.4.4, 5.2.8 of the.2011 edition); --- Changed the description of the "rolling load" test method (see 6.4.5, 5.2.9 of the.2011 edition); --- Deleted "Formaldehyde emission and water absorption thickness expansion rate test in physical and chemical performance test" and "System height test" in "Factory inspection" (6.1.1 of the.2011 edition), added "antistatic performance test" (see 7.1.1); --- Changed the contents of "Type Inspection", "Sampling Plan and Judgment Principles" and "Result Judgment" in "Inspection Rules" (see 7.1.2, 7.3, 7.4, 6.1.2, 6.3, 6.4 of.2011 version). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the State Forestry and Grassland Administration. This document is under the jurisdiction of the National Technical Committee for Standardization of Wood-Based Panels (SAC/TC198). This document was drafted by. Beijing Product Quality Supervision and Inspection Institute (National Furniture and Indoor Environment Quality Inspection and Testing Center), Changzhou Inspection and Testing Standards Certification Institute, Baroque Wood Industry (Zhongshan) Co., Ltd., Zhejiang Yunfeng Moganshan Floor Co., Ltd., Jiangsu Huidian New Materials Ltd. The main drafters of this document are. Yuan Feiyan, Zhang Xinyu, Yu Xuefei, Luo Xin, Deng Chao, Lin Deying, Fu Juejie and Zhang Yudong. The previous versions of this document and the documents it replaces are as follows. ---First published in.1999 as LY/T 1330-1999, first revised in.2011; ---This is the second revision. Antistatic wooden raised floor1 ScopeThis document specifies the structure, requirements, inspection methods, inspection rules, as well as marking, packaging, transportation and storage of antistatic wooden raised floors. Save and so on. This document is suitable for computer rooms, communication hub rooms, financial data centers, power dispatching centers and other places that require anti-static and wiring. Raised floor in the venue.2 Normative referencesThe contents of the following documents constitute the essential clauses of this document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document. GB/T 2828.1-2012 Sampling procedures for inspection by attributes Part 1.Sampling for batch inspection based on acceptance quality limit (AQL) plan GB/T 5779.1 Fastener surface defects - General requirements for bolts, screws and studs GB 8624-2012 Classification of combustion performance of building materials and products GB/T 8626-2007 Test methods for flammability of building materials GB/T 17657-2013 Test methods for physical and chemical properties of wood-based panels and veneer wood-based panels GB 18580 Limits of formaldehyde emission from artificial boards and their products for interior decoration and renovation GB/T 29899-2013 Test method for emission of volatile organic compounds from wood-based panels and their products - Small emission chamber method GB 50222-2017 Code for fire protection design of interior decoration of buildings3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 A detachable raised floor with antistatic function made of wood material. 3.2 System resistance systemresistance The resistance between the floor surface and the grounding of the supporting system. 3.3 System height systemheight The distance from the upper surface of the floor to the mounting plane. 3.4 Installation height settingheight The distance from the underside of the floor to the mounting plane. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of LY/T 1330-2023_English be delivered?Answer: Upon your order, we will start to translate LY/T 1330-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of LY/T 1330-2023_English with my colleagues?Answer: Yes. The purchased PDF of LY/T 1330-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version LY/T 1330-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version LY/T 1330-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |