| LY/T 1287-2012 English PDFLY/T 1287: Historical versions
 Basic dataStandard ID: LY/T 1287-2012 (LY/T1287-2012)Description (Translated English): Monitor and testing method of energy conservation for wood-based panel hot press Sector / Industry: Forestry Industry Standard (Recommended) Classification of Chinese Standard: F10 Classification of International Standard: 65.020.99 Word Count Estimation: 11,144 Older Standard (superseded by this standard): LY/T 1287-1998 Quoted Standard: GB 265; GB 268; GB 2587; GB 2588; GB/T 12712; GB/T 15914 Regulation (derived from): State Forestry Administration Notice 2012 No. 5; industry standard filing Notice 2012 No. 4 (No. 148 overall) Issuing agency(ies): State Forestry Administration Summary: This standard specifies the plywood hot press for energy monitoring program, monitoring methods, qualified and outcome evaluation. This standard applies to steam, thermal oil as the heat transfer medium, the production of plywood, particleboard and fiberb LY/T 1287-2012: Monitor and testing method of energy conservation for wood-based panel hot press---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Monitor and testing method of energy conservation for wood-based panel hot press ICS 65.020.99 F10 People's Republic of China Forestry Industry Standard Replacing LY/T 1287-1998 Artificial board hot press energy saving monitoring method Published on.2012-02-23 2012-07-01 implementation State Forestry Administration released ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces LY/T 1287-1998 "Energy-saving monitoring method for wood-based panel hot press". The main changes of this standard compared with LY/T 1287-1998 "Electrical Panel Hot Press Energy Saving Monitoring Method" are as follows. --- Increased the scope of application of energy-saving monitoring of wood-based panel hot presses (see Chapter 1); --- Increased energy-saving monitoring and inspection items for wood-based panel hot presses (see 3.1); --- Added heat transfer oil testing standards GB 265 and GB 268 (see Chapter 2); --- Added wood-based panel hot press inspection project (see 3.1); ---Modified the normal working conditions of energy-saving monitoring of wood-based panel hot press (see 4.1); --- Revised the inspection scope of the energy-saving monitoring sealing condition of the wood-based panel hot press (see 4.2); --- Increased inspection of the heat transfer oil index of wood-based panel hot press (see 4.6); --- Increase the ratio of the coverage area of the carbonized layer on the inner wall of the heat transfer oil pipe of the wood-based panel hot press pressure plate to the total area of the inner wall (see 4.7); --- Increased the qualified indicators for energy-saving monitoring of wood-based panel hot presses (see 5.4, 5.5); ---Modified the thermal efficiency value of the production of plywood by wood-based panel hot press (see Table 1); ---Modified the thermal efficiency value of the production of particleboard by wood-based panel hot press (see Table 1); --- Revised the thermal efficiency value of the dry production of fiberboard by wood-based panel hot press (see Table 1); ---Modified the thermal efficiency value of the fiberboard production of the wood-based panel hot press (see Table 1); --- Modified the surface temperature of the steam main pipe insulation layer (see 5.6); --- Added monitoring items in the energy-saving monitoring report of wood-based panel hot press (see Appendix C). This standard was proposed by the State Forestry Administration. This standard is supported by the National Energy Foundation and Management Standardization Technical Committee Forestry Energy Management Sub-Technical Committee (SAC/TC20/SC7) Return to the mouth. This standard is mainly drafted by. Heilongjiang Provincial Institute of Forest Engineering and Environment. Participated in the drafting of this standard. Jilin Sengong Baihe Particle Board Co., Ltd., Northeast Forestry University. The main drafters of this standard. Zhan Tingwen, Wang Fengshan, He Wei, Yue Liran, Feng Yanbin, Zhao Shaosong, Lu Yuewei, Hao Bin, Liu Wei, Song Baolin, Cao Yongzhong. This standard was first published in September.1998. This is the first revision. Artificial board hot press energy saving monitoring method1 ScopeThis standard specifies the energy-saving monitoring items, monitoring methods, qualified indicators and results evaluation of wood-based panel hot presses. This standard is applicable to intermittent hot presses for producing plywood, particleboard and fiberboard with steam and heat transfer oil as heat transfer medium.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 265 petroleum product kinematic viscosity determination method GB 268 Petroleum products carbon residue determination method GB 2587 Thermal Equipment Energy Balance General General rules for thermal efficiency calculation of GB 2588 equipment GB/T 12712 steam heating system condensate recovery and steam trap technical management requirements GB/T 15914 steam heating equipment energy-saving monitoring method3 Monitoring project3.1 Inspection items Inspection items include. a) sealing condition of hot-press machine steam-water pipeline and heat-conducting oil pipeline; b) The heat preservation condition of the main pipeline of steam and heat transfer oil; c) condensate recovery and utilization; d) thermal efficiency of the hot press; e) heat exchanger oil index; f) The ratio of the coverage area of the carbonized layer on the inner wall of the heat transfer oil pipe of the hot press plate to the total area of the working surface. 3.2 Test project Test items include. a) steam trap leakage rate; b) condensate temperature; c) Surface temperature of the main steam insulation layer.4 Monitoring methods4.1 Monitoring requirements Monitoring should be carried out under normal production conditions. The monitoring system consists of the hot press body and its inlet main valve to the trap outlet or condensate ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of LY/T 1287-2012_English be delivered?Answer: Upon your order, we will start to translate LY/T 1287-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of LY/T 1287-2012_English with my colleagues?Answer: Yes. The purchased PDF of LY/T 1287-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version LY/T 1287-2012?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version LY/T 1287-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |