JJG 169-2010 English PDFUS$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 169-2010: Verification regulation of transformer test set Status: Valid JJG 169: Historical versions
Basic dataStandard ID: JJG 169-2010 (JJG169-2010)Description (Translated English): Verification regulation of transformer test set Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A55 Classification of International Standard: 17.220 Word Count Estimation: 19,131 Date of Issue: 2010-11-05 Date of Implementation: 2011-05-05 Older Standard (superseded by this standard): JJG 169-1993 Quoted Standard: JJG 124-2005 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to using the difference method principle, the operating frequency of 50Hz, measuring current transformer and voltage transformer ratio errors transformer calibrator (hereinafter referred to as calibrator) the initial verification, testing and use of follow-up inspection. JJG 169-2010: Verification regulation of transformer test set---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification regulation of transformer test set State verification procedures People's Republic of China Transformer calibrator Issued on. 2010-11-05 2011-05-05 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Transformer calibrator verification procedures Replacing JJG 169-1993 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on November 5, 2010, and from From May 5, 2011 implemented. Focal point. the National Technical Committee on Electromagnetic measurement The main drafting units. the national high voltage metering station Participated in the drafting unit. Hubei Electric Power Research Institute Zhejiang Electric Power Test & Research Institute Xinjiang Institute of Metrology Ningbo three-dimensional measuring equipment Limited The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic The main drafters of this procedure. Wangle Ren (the national high voltage metering station) Zhang said the Chinese (the national high voltage metering station) Jen opened (the national high voltage metering station) Drafters participate. Shu open flag (Hubei Electric Power Research Institute) Xuling Jie (Zhejiang Electric Power Research Institute) Song Wei (Xinjiang Institute of Metrology) Heavy Zhu Ye (Electrical Measuring Equipment Co., Ltd. Ningbo three-dimensional) table of Contents1 Scope (1) 2. Referenced Documents (1) 3 Overview (1) 4 metering performance requirements (1) 4.1 accuracy class (1) 4.2 basic error (1) 4.3 dial (2) 4.4 Resolution (2) 4.5 harmonic suppression (2) Load capacity 4.6 (2) 4.7 Stability Assessment (2) 5 General Requirements (2) 5.1 grounding and insulation (2) 5.2 input terminal and flags (3) 6 Control of measuring instruments (3) 6.1 Verification condition (3) 6.2 Verification Project (4) 6.3 Verification Methods (4) Processing 6.4 Verification Results (6) 6.5 test cycle (6) Appendix A test recording format (7) Appendix B test certificate page format (9) Appendix C test results in the notice page format (11) Appendix D transformer calibrator overall verification device calibration method (13) Transformer calibrator verification procedures1 ScopeThe order applies to the principle of using the difference method, the operating frequency of 50Hz, the measured current and voltage transformers Proportional error of transformer calibrator (hereinafter referred to as calibrator) initial verification, subsequent verification and in-service inspection.2 CitationsThe regulations cited in the following documents. JJG 124-2005 ammeter, voltmeter, power meter and resistance meter testing procedures When using this procedure, it should pay attention to using the currently valid version of the documents cited.3 OverviewTransformer Calibrator is a measurement of power frequency voltage (or current) proportional error of the instrument while working electrical calibrator , Differential pressure (or differential current) is applied to the loop error voltage (or voltage (or current) is applied to the test circuit voltage (or current) Flow), the calibrator can be obtained differential pressure (or differential current) phase through a bridge line, electronic circuits, digital circuits or measuring The amount with respect to the operating voltage (or current) relative to the amount of in-phase and quadrature components, can be obtained by calculation are compared Voltage (or current) relative to the amount of the operating voltage (or current) phasor amplitude ratio (ratio of the difference) and phase. If Comparing a voltage (or current) relative to the amount of lead working voltage (or current) phasors, the phase difference is positive and negative hysteresis. From the measurement principle, calibrator Electrical and electronic can be divided into two categories. Electrical bridge formula by measuring line, Need for balance adjustment of the bridge. Electronic through electronic circuits or digital circuits result of the measurement with digital display Shown, it may have a range of automatic conversion function. Measurement indication calibrator has three representations. Under normal circumstances the ratio of the difference in percentage (%), with a phase difference [Angle] minute ( '); or the ratio of the difference in percentage (%), the phase difference with PCT radians (crad); or the ratio of the difference 10 The negative exponential power (10-n), the phase difference in radians multiplied by a negative exponential power (10-nrad) 10 in.4 metering performance requirements4.1 accuracy class Press transformer calibrator accuracy class is divided into Level 1, Level 2 and Level 3. 4.2 basic error 4.2.1 In table 1 of reference conditions, the ratio of the error manually-range calibrator each range shall not exceed Formula (1) limits given phase error shall not exceed the formula (2) given limits. Table 1 The basic error of reference conditions Ambient temperature Relative humidity Power frequency Voltage and current percentage Power waveform The distortion factor Environmental Field Disturbance 0 ℃ ~ 40 ℃ ≤80% 50Hz ± 0.5Hz 20% to 120% / 5% to 120% ≤5% No more than the minimum scale value 1/2 or quantized values ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 169-2010_English be delivered?Answer: Upon your order, we will start to translate JJG 169-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 169-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJG 169-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 169-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 169-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |