JJF 1826-2020 English PDFUS$459.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1826-2020: Calibration Specification for Air Microorganism Samplers Status: Valid
Basic dataStandard ID: JJF 1826-2020 (JJF1826-2020)Description (Translated English): Calibration Specification for Air Microorganism Samplers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A50 Classification of International Standard: 17.020 Word Count Estimation: 20,237 Date of Issue: 2020 Date of Implementation: 2020-04-17 Issuing agency(ies): State Administration for Market Regulation JJF 1826-2020: Calibration Specification for Air Microorganism Samplers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration Specification for Air Microorganism Samplers National Measurement Technical Specification of the People's Republic of China Air microbial sampler calibration specification 2020-01-17 release 2020-04-17 Implementation Issued by the State Administration of Market Supervision and Administration Air microorganism sampler Calibration specifications Focal point. National Biometrics Technical Committee Main drafting unit. Hebei Institute of Metrology Supervision and Inspection Chinese Academy of Metrology Participated in the drafting unit. Suzhou Noda Purification Technology Co., Ltd. This specification entrusts the National Biometrics Technical Committee to interpret The main drafters of this specification. Song Zengliang (Hebei Metrology Supervision and Inspection Research Institute) Fu Boqiang (Chinese Academy of Metrology) Feng Jinmiao (Hebei Metrology Supervision and Inspection Research Institute) Sui Zhiwei (Chinese Academy of Metrology) Participating drafters. Hao Jingkun (Hebei Institute of Metrology, Inspection and Testing) Lin Guoxi (Suzhou Nuoda Purification Technology Co., Ltd.) table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terms and units of measurement (1) 4 Overview (1) 5 Metrological characteristics (2) 5.1 Flow indication error (2) 5.2 Flow repeatability (2) 5.3 Flow stability (2) 5.4 Timing error (2) 5.5 Sampling physical efficiency (2) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Reference materials and other equipment (2) 6.3 Reagents and culture media (3) 7 Calibration items and calibration methods (3) 7.1 Flow indication error (3) 7.2 Flow repeatability (3) 7.3 Flow stability (3) 7.4 Timing error (4) 7.5 Sampling physical efficiency (4) 8 Expression of calibration results (5) 9 Recalibration time interval (5) Appendix A Preparation of Standard Strain Suspension (6) Appendix B Method for measuring the diameter of aerosols containing microbial particles (7) Appendix C Preparation of Medium (8) Appendix D Example of Uncertainty Evaluation of Measurement Results of Flow Indication Error (9) Appendix E Examples of Uncertainty Evaluation of Sampling Physical Efficiency Measurement Results (11) Appendix F Calibration Record Format of Air Microbial Sampler (for reference) (13) Appendix G Calibration Certificate (Inner Page) Format (For Reference) (15)IntroductionThis specification is based on JJF 1071-2010 "Rules for Compiling National Measurement and Calibration Specifications", JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Expression", JJF 1001-2011 "General Measurement Terms and Definitions" provisions. this The main technical indicators of the specification refer to GB/T 16293-2010 "Test of planktonic bacteria in the clean room (area) of the pharmaceutical industry Method "and ISO 14698-1..2003" Clean Room and Related Controllable Environment Biological Pollution Control Part 1.One "General Principles and Methods" Appendix B Guiding Principles for Air Sampler Verification [Cleanrooms and associatedcon- troledenvironments-Biocontaminationcontrol-Part 1.Generalprinciplesandmeth- ods, AnnexB (informative) Guidanceonvalidatingairsamplers]. This specification is the first release. Air microbial sampler calibration specification1 ScopeThis specification applies to the calibration of air microbial samplers based on the Anderson impact method.2 Reference documentsThis specification refers to the following documents. GB/T 16293-2010 Test method for planktonic bacteria in clean room (area) of pharmaceutical industry ISO 14698-1..2003 Clean room and related controllable environment biological pollution control Part 1.General principles Cleanroomsandassociatedcontroledenvironments-Biocontaminationcon- trol-Part 1.Generalprinciplesandmethods) For dated reference documents, only the dated version applies to this specification; for those without date references The latest version (including all amendments) is applicable to this specification.3 Terms and units of measurement3.1 Bioaerosol A colloidal system formed by biological particles suspended in air, that is, an aerosol containing biological particles. Including bacteria, Viruses and allergenic pollen, mold spores and fern spores, in addition to the characteristics of general aerosols, Dyeability, sensitization, etc. 3.2 Living unit viableunit, VU One or more living particles (particles can contain one or more living microorganisms), when counted as 1, it is called 1 living individual. Note. When the number of live individuals is to count the colonies on the agar medium, it is usually called colony forming unit (colony formingunits, CFU). A CFU can contain one or more VUs. 3.3 Physical efficiency of sampling physical efficiency of sampling Sampler's collection efficiency for particles of different sizes. Note. The particles can be microorganisms, particles carrying microorganisms or non-viable particles. Sampling the above particles with the same particle size The physical efficiency is the same.4 OverviewAir microbial sampler (hereinafter referred to as sampler) is a sampling instrument specially used to collect microorganisms in the air. It is based on the principle of the Anderson impact method, which extracts air at a certain flow rate, so that the microbial particles in the air flow accelerate to impact The surface of the petri dish of the nutrient agar medium is cultivated to form colonies visible to the naked eye. The sample volume calculates the concentration of live individuals in the air. The sampler is usually composed of a protective cover, a sampling head (including mesh type, radial slit type, centrifugal type, etc.), It consists of data processing system and display system. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1826-2020_English be delivered?Answer: Upon your order, we will start to translate JJF 1826-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1826-2020_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1826-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |