JJF 1770-2019: Rules of Metrology Testing for Energy Efficiency of Multi-connected Air-condition(heat pump) Units
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1770-2019889 Add to Cart 6 days Rules of Metrology Testing for Energy Efficiency of Multi-connected Air-condition(heat pump) Units Valid

Similar standards

JJF 1835   JJF 1800   JJF 1071   JJF 1768   JJF 1769   JJF 1766   

Basic data

Standard ID: JJF 1770-2019 (JJF1770-2019)
Description (Translated English): Rules of Metrology Testing for Energy Efficiency of Multi-connected Air-condition(heat pump) Units
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A50
Classification of International Standard: 17.020
Word Count Estimation: 41,495
Date of Issue: 2019
Date of Implementation: 2019-12-27
Issuing agency(ies): State Administration for Market Regulation

JJF 1770-2019: Rules of Metrology Testing for Energy Efficiency of Multi-connected Air-condition(heat pump) Units


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Multi-unit air conditioning (heat pump) unit energy efficiency measurement and detection rules) National Metrology Technical Specifications of the People's Republic of China Multi-connected air conditioning (heat pump) unit Energy efficiency measurement and testing rules 2019-09-27 released 2019-12-27 Implementation Issued by the State Administration for Market Regulation Multi-connected air conditioning (heat pump) unit Energy efficiency measurement and testing rules Focal point. National Technical Committee for Legal Metrology Management Energy Efficiency Label Metrology and Testing Sub-Technical Committee Main drafting unit. Hefei General Mechanical and Electrical Products Testing Institute Co., Ltd. Participated in the drafting unit. China Institute of Metrology Guangdong Midea HVAC Equipment Co., Ltd. Daikin (China) Investment Co., Ltd. Shanghai Branch Qingdao Hisense Hitachi Air Conditioning System Co., Ltd. This specification entrusts the National Legal Metrology Management Metrology Technical Committee Energy Efficiency Label Metrology and Testing Sub-Technical Committee to be responsible for the interpretation The main drafters of this specification. Li Daoping (Hefei General Mechanical and Electrical Products Testing Institute Co., Ltd.) Yu Xiaolin (Hefei General Mechanical and Electrical Products Testing Institute Co., Ltd.) Chen Pu (Hefei General Mechanical and Electrical Products Testing Institute Co., Ltd.) Participating drafters. Xu Dinghua (China Institute of Metrology) Xiao Jinsong (Guangdong Midea HVAC Equipment Co., Ltd.) Zhang Jianqiang [Daikin (China) Investment Co., Ltd. Shanghai Branch] Zhang Wenqiang (Qingdao Hisense Hitachi Air Conditioning System Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 scope (1) 2 Reference documents (1) 3 Terms and measurement units (1) 3.1 Cooling capacity(1) 3.2 Cooling power consumption (1) 3.3 Refrigeration energy efficiency ratio (1) 3.4 Refrigeration comprehensive performance coefficient [IPLV (C)] (1) 3.5 Energy efficiency limit value (2) 3.6 Energy efficiency rating (2) 3.7 Air enthalpy difference method (2) 4 Overview (2) 5 Measurement requirements (2) 5.1 Energy efficiency labeling (2) 5.2 Energy efficiency indicators (energy consumption) (2) 5.3 Energy efficiency rating (3) 6 Testing conditions (3) 6.1 Environmental conditions (3) 6.2 Measuring equipment (3) 6.3 Measurement uncertainty (4) 7 Test items and methods (4) 7.1 Sampling principles and methods (4) 7.2 Sample testing (4) 7.3 Original record (6) 7.4 Data processing(6) 8 Test results (6) 8.1 Eligibility criteria for energy efficiency indicators (energy consumption) measurement test results (6) 8.2 Judgment criteria for test results (7) 8.3 Test report(8) Appendix A Multi-connected cooling capacity air enthalpy difference measurement method (9) Appendix B Test and calculation of multi-line refrigeration comprehensive performance coefficient [IPLV (C)] (14) Appendix C Example of Uncertainty Evaluation of Indoor Air Enthalpy Difference Method Multi-connected Energy Efficiency Measurement (17) Appendix D Multi-connected air conditioning (heat pump) unit energy efficiency measurement test sampling sheet (format) (27) Appendix E. Original record of energy efficiency measurement and inspection of multi-connected air-conditioning (heat pump) units (format) (28) Appendix F Multi-connected air conditioning (heat pump) unit energy efficiency measurement test report (format) (31)

Introduction

In order to standardize the implementation of energy efficiency labeling management of multi-unit air conditioning (heat pump) units (hereinafter referred to as "multi-unit Machine”) energy efficiency measurement and testing work, according to JJF 1261.1-2017 "Energy efficiency measurement and testing of energy-using products According to the requirements of the Rules, this specification is formulated. This specification is released for the first time. Multi-connected air conditioning (heat pump) unit Energy efficiency measurement and testing rules

1 Scope

This specification specifies the energy efficiency measurement requirements, measurement testing procedures, and Measurement and testing methods, measurement and testing results evaluation criteria and testing reports, etc. This specification applies to multi-line energy efficiency measurement supervision and testing, and commissioned testing can refer to this specification. Production and Sales of multi-line units can also refer to this specification for testing. The multi-line energy efficiency measurement and detection method specified in this specification is the air enthalpy difference method. This specification does not apply to units with dual refrigeration cycle systems and multiple refrigeration cycle systems. The multi-line tested should be products that have passed the self-inspection of the manufacturer, or the products imported and sold by the seller.

2 Reference documents

This specification refers to the following documents. JJF 1261.1-2017 Energy efficiency measurement and testing rules for energy-using products GB/T 2829-2002 Periodic Inspection Attribute Sampling Procedure and Table (Applicable to the Inspection of Process Stability) GB/T 17758-2010 Unit type air conditioner GB/T 18837-2002 Multi-connected air conditioning (heat pump) unit GB 21454-2008 Multi-connected air conditioning (heat pump) unit energy efficiency limit value and energy efficiency grade GB 27941-2011 Application design and installation requirements for multi-unit air conditioning (heat pump) units For dated reference documents, only the dated version applies to this specification; for undated reference documents, The latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

The following terms and measurement units apply to this specification. 3.1 Cooling capacity Under the specified refrigeration capacity test conditions, the unit of measurement is W for the heat exhausted from enclosed spaces, rooms or areas on multiple lines. 3.2 Cooling power consumption Under the specified refrigeration capacity test conditions, the total power consumed during multi-line operation is measured in W. 3.3 Refrigeration energy efficiency ratio energyefficiencyratio Under the specified refrigeration capacity test conditions, the ratio of multi-line refrigeration capacity to refrigeration power consumption is measured in W/W. 3.4 Refrigeration comprehensive performance coefficient A test and calculated according to the method described in Appendix B, describing the value of multi-line part-load cooling efficiency, the unit of measurement is W/W.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1770-2019_English be delivered?

Answer: Upon your order, we will start to translate JJF 1770-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1770-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1770-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries