Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1768-2019 English PDF

US$889.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1768-2019: Rules of Metrology Testing for Energy Efficiency of Heat Pump Water Heaters
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1768-2019889 Add to Cart 6 days Rules of Metrology Testing for Energy Efficiency of Heat Pump Water Heaters Valid

Similar standards

JJF 1835   JJF 1800   JJF 1071   JJF 1769   JJF 1770   JJF 1766   

Basic data

Standard ID: JJF 1768-2019 (JJF1768-2019)
Description (Translated English): Rules of Metrology Testing for Energy Efficiency of Heat Pump Water Heaters
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A50
Classification of International Standard: 17.020
Word Count Estimation: 41,488
Date of Issue: 2019
Date of Implementation: 2019-12-27
Issuing agency(ies): State Administration for Market Regulation

JJF 1768-2019: Rules of Metrology Testing for Energy Efficiency of Heat Pump Water Heaters

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Heat pump water heater (heater) energy efficiency measurement and testing rules) National Metrology Technical Specifications of the People's Republic of China Energy efficiency measurement of heat pump water heater Detection rules WaterHeaters 2019-09-27 released 2019-12-27 Implementation Issued by the State Administration for Market Regulation Energy efficiency of heat pump water heater Measurement and detection rules Focal point. National Technical Committee for Legal Metrology Management Energy Efficiency Label Metrology and Testing Sub-Technical Committee Main drafting unit. Guangdong Institute of Metrology Participating in the drafting unit. Guangdong Wanhexin Electric Co., Ltd. Zhuhai Gree Electric Co., Ltd. China Saibao Laboratory Chongqing Institute of Metrology and Quality Inspection This specification entrusts the National Legal Metrology Management Metrology Technical Committee Energy Efficiency Label Metrology and Testing Technology The technical committee is responsible for explaining The main drafters of this specification. Wu Zhongjie (Guangdong Institute of Metrology) Zhou Dengjin (Guangdong Institute of Metrology) Wu Jianou (Guangdong Institute of Metrology) Participating drafters. Huang Xunqing (Guangdong Wanhe New Electric Co., Ltd.) Lin Aige (Zhuhai Gree Electric Appliance Co., Ltd.) Xiao Shiman (China Saibao Laboratory) Luo Lincong (Chongqing Institute of Metrology and Quality Inspection)

table of Contents

Introduction (Ⅱ) 1 scope (1) 2 Reference documents (1) 3 Terms and measurement units (1) 4 Overview (2) 5 Measurement requirements (2) 5.1 Energy efficiency labeling (2) 5.2 Energy efficiency indicators (energy consumption) (2) 5.3 Energy efficiency rating (3) 6 Testing conditions (3) 6.1 Test conditions (3) 6.2 Testing equipment (4) 6.3 Measurement uncertainty (4) 7 Test items and methods (5) 7.1 Sampling principles and methods (5) 7.2 Sample testing (5) 7.3 Original record (10) 7.4 Data processing(10) 8 Test results (10) 8.1 Eligibility criteria for energy efficiency indicators (energy consumption) measurement test results (10) 8.2 Judgment criteria for test results (11) 8.3 Test report (11) Appendix A Example of Uncertainty Evaluation of Energy Efficiency Measurement of Heat Pump Water Heater (13) Appendix B Sampling Sheet for Energy Efficiency Measurement and Testing of Heat Pump Water Heater (Appliance) (Format) (26) Appendix C Original Record of Energy Efficiency Measurement and Testing of Heat Pump Water Heater (Appliance) (Format) (27) Appendix D Energy Efficiency Measurement Test Report of Heat Pump Water Heater (Appliance) (Format) (31)

Introduction

In order to standardize the energy efficiency measurement and inspection work of heat pump water heaters (heaters) that implement energy efficiency label management, according to According to the requirements of JJF 1261.1-2017 "Energy Efficiency Measurement and Testing Rules for Energy-using Products", this specification is formulated. This specification is released for the first time. Energy efficiency measurement of heat pump water heater Detection rules

1 Scope

This specification stipulates that it is driven by an electric motor, adopts a vapor compression refrigeration cycle, and uses air as a heat source to provide hot water Energy efficiency measurement requirements, measurement testing procedures, measurement testing methods, and measurement of heat pump water heaters (appliances) for the purpose Test results evaluation criteria and test reports, etc. This specification is applicable to the energy efficiency measurement supervision and testing of heat pump water heaters (appliances). For entrusted testing, please refer to this specification. Row. Units that produce and sell heat pump water heaters (appliances) can also conduct inspections with reference to this specification. This specification does not apply to water source heat pump water heaters. The heat pump water heater (device) to be tested should be a product that has passed the self-inspection of the manufacturer, or imported or sold by the seller. Merchandise for sale.

2 Reference documents

This specification refers to the following documents. JJF 1261.1-2017 Energy efficiency measurement and testing rules for energy-using products GB/T 2829-2002 Periodic Inspection Attribute Sampling Procedure and Table (Applicable to the Inspection of Process Stability) GB/T 21362-2008 Commercial or industrial heat pump water heaters and similar uses GB/T 23137-2008 Household and similar heat pump water heaters GB 29541-2013 Heat pump water heater (heater) energy efficiency limit value and energy efficiency grade For dated reference documents, only the dated version applies to this specification; for undated references The latest version (including all amendments) is applicable to this specification.

3 Terms and units of measurement

The following terms and measurement units apply to this specification. 3.1 Primary heating heat pump water heater (device) instantaneousheatpumpwaterheater The initial cold water flows through the heat exchanger inside the heat pump water heater (heater) once to reach the heat pump heat set by the user Water machine (apparatus). 3.2 Circulating heating heat pump water heater (device) circulatingheatpumpwaterheater The initial cold water flows through the heat exchanger in the heat pump water heater (heater) several times and gradually reaches the heat pump water heater (heater) of the set temperature. 3.3 Static heating heat pump water heater (device) staticheatpumpwaterheater Through the direct or indirect contact of the heat exchanger with the water, the heated water side gradually reaches the set temperature in the form of natural convection The temperature of the heat pump water heater. 3.4 Heatingcapacity Under the specified test conditions and conditions, the heat provided by the heat pump water heater per unit time to the heated water is calculated. The unit of measure is W.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1768-2019_English be delivered?

Answer: Upon your order, we will start to translate JJF 1768-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1768-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1768-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.