JJF 1705-2018: Calibration Specification for Artificial Mains Networks
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1705-2018509 Add to Cart 4 days Calibration Specification for Artificial Mains Networks Valid

Similar standards

JJF 1234   JJF 1396   JJG 376   JJF 1706   JJF 1710   JJF 1703   

Basic data

Standard ID: JJF 1705-2018 (JJF1705-2018)
Description (Translated English): Calibration Specification for Artificial Mains Networks
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A56
Classification of International Standard: 17.220
Word Count Estimation: 22,267
Date of Issue: 2018-06-25
Date of Implementation: 2018-09-25
Quoted Standard: GB/T 6113.102-2008; GB/T 6113.201; GB 1002
Regulation (derived from): State Administration of Markets, Announcement No. 13 of 2018
Issuing agency(ies): State Administration for Market Regulation
Summary: This standard is applicable to V-type artificial power supply in accordance with GB/T 6113.102-2008 "Radio disturbance and immunity measurement equipment and measurement method specification Part 1-2: Radio disturbance and immunity measurement equipment auxiliary equipment conducted disturbance" Calibration of the network (hereafter referred to as "artificial power network"). Three types are included: 1) 50��/50H+5��, operating frequency range 9 kHz to 150 kHz; 2) 50 ��/50 ��H type, operating frequency range 0.15 MHz to 30 MHz; 3) 50 ��/5 ��H +1 �� type The operating frequency range is from 0.15 MHz to 108 MHz.

JJF 1705-2018: Calibration Specification for Artificial Mains Networks

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Artificial Mains Networks National Metrology Technical Specification of the People's Republic Artificial power network calibration specification Published on.2018-06-25 2018-09-25 implementation State Administration of Markets issued Artificial power network calibration specification Focal Point. National Radio Measurement Technology Committee Main drafting unit. Jiangsu Institute of Metrology China Institute of Metrology Participated in the drafting unit. Liaoning Institute of Metrology This Code entrusts the National Radio Measurement Technical Committee to explain The main drafters of this specification. Feng Zhiming (Jiangsu Institute of Metrology) Li Wei (China Institute of Metrology) Zhao Pinzhang (Jiangsu Institute of Metrology) Participate in the drafters. Li Lin (Jiangsu Institute of Metrology) Hao Song (Liaoning Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 terms (1) 3.1 Asymmetric voltage (1) 3.2 Test end impedance (1) 3.3 Partial pressure coefficient (1) 4 Overview (1) 5 Measurement characteristics (2) 5.1 Test end impedance (2) 5.2 Partial pressure coefficient (4) 6 Calibration conditions (4) 6.1 Environmental conditions (4) 6.2 Measurement standards and other equipment (5) 7 Calibration items and calibration methods (5) 7.1 Appearance and normality check (5) 7.2 Calibration of the test end impedance (5) 7.3 Calibration of partial pressure coefficient (6) 8 Calibration result expression (7) 9 re-study interval (8) Appendix A Original Record Format (9) Appendix B Calibration Certificate Page Format (10) Appendix C Example of Calibration Uncertainty Evaluation (11) Appendix D Reference Mechanical Structure for Calibration Adapter (17)

Introduction

This specification is prepared in accordance with JJF 1071-2010 “Rules for the Preparation of National Metrology Calibration Specifications”, JJF 1001 Measurement Terms and Definitions, JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Representation" together constitute the support of this regulation The basic series of specifications for the development of the work. This specification refers to GB/T 6113.102-2008 "Radio disturbance and immunity measurement equipment and measurement methods Part 1-2. Radio disturbance and immunity measurement equipment, auxiliary equipment conducted disturbances, GB/T 6113.201-2017 "Specifications for radio disturbance and immunity measuring equipment and methods of measurement - Part 2-1. Radio disturbance and immunity measurement method for conducted disturbance measurement, GB 1002-2008 "Household and similar use list Compilation of relevant provisions for phase plug and socket type, basic parameters and dimensions. This specification is the first release. Artificial power network calibration specification

1 Scope

This specification applies to GB/T 6113.102-2008 "Radio disturbance and immunity measurement equipment and measurement". Method Specification Part 1-2. Requirements for Conducted Harassment in Auxiliary Equipment for Radio Disturbance and Immunity Measurement Equipment Calibration of a V-type artificial power network (hereinafter referred to as "artificial power network"). Includes three types. 1) 50Ω/50μH 5Ω type, the operating frequency range is 9kHz~150kHz; 2) 50Ω/50μH type, the operating frequency range is 0.15MHz~30MHz; 3) 50Ω/5μH 1Ω type, the operating frequency range is 0.15MHz~108MHz.

2 reference files

This specification refers to the following documents. GB/T 6113.102-2008 Specification for radio disturbance and immunity measuring equipment and measuring methods - Part 1-2 Points. Radio disturbance and immunity measurement equipment auxiliary equipment conducted disturbance GB/T 6113.201 Radio disturbance and immunity measurement equipment and methods of measurement - Part 2-1. Line electrical disturbance and immunity measurement method conducted disturbance measurement GB 1002 Single-phase plug and socket type and basic parameters and dimensions for household and similar purposes For dated references, only dated versions apply to this specification; undated quotations The latest version (including all amendments) applies to this specification.

3 terms

3.1 asymmetric voltage unsymmetricvoltage The vector magnitude of the RF disturbance voltage that appears between a single power terminal and ground. 3.2 Test end impedance EUTportimpedance Refers to the line terminal and reference of the device under test when the disturbance output of the artificial power network is terminated with a 50Ω load impedance. High frequency impedance (modulus and phase angle) between the test sites. 3.3 partial pressure coefficient voltagedivisionfactor Refers to the high frequency signal fed from the device under test, transmitted to the disturbance output via the internal power supply network (built-in attenuation) The magnitude of the amplitude experienced by the device within the calculation range.

4 Overview

The artificial power network is an instrument used in electromagnetic compatibility radio disturbance measurement tests to measure power lines and parameters. The disturbance voltage radiated externally between the test sites is usually an asymmetric voltage. Artificial power network in the harassment test The role of the quantity is. 1) providing a specified impedance to the terminals of the device under test in the RF frequency range; 2) coupling the disturbance voltage emitted by the device under test to the disturbance measuring device;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1705-2018_English be delivered?

Answer: Upon your order, we will start to translate JJF 1705-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1705-2018_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1705-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.