JJF 1621-2017 English PDFUS$419.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1621-2017: Calibration Specification for Diagnostic Dosimeters Status: Valid
Basic dataStandard ID: JJF 1621-2017 (JJF1621-2017)Description (Translated English): Calibration Specification for Diagnostic Dosimeters Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 18,172 Date of Issue: 2017-02-28 Date of Implementation: 2017-05-28 Quoted Standard: GB/T 19629-2005; IAEATRS 457; IEC 61267-2005; IEC 61674-2012 Adopted Standard: IEC 61674-2012, NEQ Regulation (derived from): General Administration of Quality Supervision, Inspection and Quarantine No. 23 of 2017 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard is applicable to the calibration of a 40 to 150 kV X-ray diagnostic level dosimeter or detector, CT dosimeter or detector. JJF 1621-2017: Calibration Specification for Diagnostic Dosimeters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration Specification for Diagnostic Dosimeters National Metrological Technical Code of the People's Republic of China Diagnostic level dosimeter calibration specification 2017-02-28 released 2017-05-28 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Diagnostic level dosimeter calibration specification Unit. National Diameter Radiation Metrology Technical Committee The main drafting unit. Beijing Institute of Metrology and Testing China Testing Technology Research Institute Participated in the drafting unit. Shanghai Institute of Metrology and Testing Technology This specification entrusts the National Diameter Radiation Metrology Technical Committee to explain The main drafters of this specification. Guo Hongtao (Beijing Institute of Metrology and Measurement) Zhang Yuanyue (China Test Technology Research Institute) Xu Shi Meng (China Test Technology Research Institute) Participate in the drafters. Yang Gan (China Test Technology Research Institute) Luo Chen (Beijing Institute of Metrology and Testing) Huang Xinsheng (Beijing Institute of Metrology and Measurement Science) Teng Jingjing (Shanghai Institute of Metrology and Testing Technology) table of ContentsIntroduction (II) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Terms (1) 3.2 Units of measurement (2) 4 Overview (2) 5 Metrological characteristics (2) 6 Calibration conditions (2) 6.1 Environmental conditions (2) 6.2 Measurement standards and other measuring equipment (3) 6.3 Radiation field (3) 7 Calibration items and calibration methods (3) 7.1 Calibration items (3) 7.2 Repetitive (3) 7.3 Calibration factors (4) 7.4 Energy response (6) 7.5 Long-term stability (6) 8 Calibration results (6) 9 re-school time interval (6) Appendix A RQR, RQA and RQT Series Radiation (7) Appendix B Diagnostic Level Dosimeter Calibration Record Recommended Format (8) Appendix C Diagnostic Level Dosimeter Calibration Certificate Inside Page Format (9) Appendix D Diagnostic Level Dosimeter Calibration Factor Uncertainty Evaluation Example (10)IntroductionThis specification is prepared in accordance with the requirements of JJF 1071-2010 "Rules for the Preparation of National Metrological Calibration Standards" According to IEC 61674-2012 "Medical Electrical Equipment X-ray diagnostic images used in ionization chambers and/or semiconductors Sensorless dosimeter "(Medicalelectricalequipment-Dosimeters withionizationchambers) and/orsemiconductordetectorsasusedinX-raydiagnosticimaging), GB/T 19629- 2005 "Medical electrical equipment X-ray diagnostic images used in the ionization chamber and/or semiconductor detector dosimeter" And IAEATRS457 "Radiation Diagnostic Dosage. Implementation Guide" (Dosimetryin DiagnosticRadiology. AnInternationalCodeofPractice). This specification is the first release. Diagnostic level dosimeter calibration specification1 ScopeThis specification applies to measuring (40 to 150) kV X-ray diagnostic level dosimeters or detectors, CT dosimeters or Detector calibration.2 reference fileThis specification refers to the following documents. GB/T 19629-2005 Medical electrical equipment X-ray diagnostic images used in the ionization chamber and/or half Conductor Detector Dosimeter IAEATRS457 Radiation Diagnostic Dosage. Implementation Guidelines (DosimetryinDiagnosticRadiology. AnInternationalCodeofPractice) IEC 61267-2005 Medical diagnostic X-ray equipment Measurement characteristics Radiation conditions used (Medicaldi- agnosticX-rayequipment-Radiationconditionsforuseinthedetermination ofcharac- teristics IEC 61674-2012 Medical devices and/or semiconductors for use in X-ray diagnostic imaging Device dosimeter (Dyimeterswithionizationchambersand/or semiconductordetectorsasusedinX-raydiagnosticimaging) For dated references, only the dated edition applies to this specification; references that are not dated , The latest version (including all modifications) applies to this specification.3 terms and units of measurement3.1 terminology 3.1.1 diagnostic level dosimeter diagnosticdosimeter Measuring the air kerma energy of the X-ray machine beam diagnosed with medical radiation by an ionization chamber or a semiconductor detector, Air ratio kinetic energy length product or air kerma rate of the device. 3.1.2 Air ratio kinetic energy length product airkermalengthproduct (PKL) For any straight line passing through the CT X-ray scanning cross section, the air kerma length is above the straight line Integration of gas kinetic energy and length product. 3.1.3 calibration factor calibrationfactor The reference value is divided by the quotient. 3.1.4 energy response energyresponse The response of the detector varies with the radiant energy. 3.1.5 non-diminished beam unattenuatedbeam An X-ray beam that strikes the subject or the mold body. 3.1.6 non-reduced beam unattenuatedbeamquality (RQR) ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1621-2017_English be delivered?Answer: Upon your order, we will start to translate JJF 1621-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1621-2017_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1621-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |