Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1543-2015 English PDF

US$649.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1543-2015: Calibration Specification for Visual Electrophysiological Instruments
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1543-2015649 Add to Cart 5 days Calibration Specification for Visual Electrophysiological Instruments Valid

Similar standards

JJG 879   JJF 1106   JJG 810   JJF 1544   JJF 1546   JJF 1539   

Basic data

Standard ID: JJF 1543-2015 (JJF1543-2015)
Description (Translated English): Calibration Specification for Visual Electrophysiological Instruments
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A60
Classification of International Standard: 17.180
Word Count Estimation: 28,29
Date of Issue: 2015-08-24
Date of Implementation: 2015-11-24
Quoted Standard: ISCEV(2003)
Regulation (derived from): AQSIQ Announcement 2015 No.106
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard applies to the clinical use of visual electrophysiology instrument calibration.

JJF 1543-2015: Calibration Specification for Visual Electrophysiological Instruments

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for Visual Electrophysiological Instruments People's Republic of China National Metrology Technical Specifications Calibration Specification for visual electrophysiology Issued on. 2015-08-24 2015-11-24 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Calibration Specification for visual electrophysiology Focal point. the National Technical Committee on Medical Measurement The main drafting units. China Institute of Metrology Participated in the drafting. Special Medical Equipment Co., Chongqing, China Shandong Province Institute of Metrology Chinese Academy of Sciences Institute of Optical Technology This specification entrusted to the National Technical Committee is responsible for interpreting medical measurement The main drafters of this specification. Set Xiang (China Institute of Metrology) HE Yu (Chongqing, China Special Medical Equipment Co., Ltd.) Zhang Ji Yan (China Institute of Metrology) Drafters participate. Sun Xin (Shandong Province Institute of Metrology) Bai Wei (Chongqing States special medical equipment Limited) Shi Guohua (Institute of Optoelectronic Technology Institute)

table of Contents

Introduction (Ⅲ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 average luminance pattern (1) 3.2 Graphics contrast (1) 3.3 brightness uniformity (1) 3.4 flash intensity (1) 3.5 flash duration (1) Latency 3.6 (1) 4 Overview (1) 5 Metrological characteristics (1) 5.1 flash intensity setting error (1) 5.2 flash duration (2) 5.3 flash stimulator background brightness setting error (2) 5.4 Graphics Contrast (2) 5.5 Graphics average brightness setting value error (2) 5.6 Graphics stimulator luminance uniformity (2) 5.7 shows the magnitude of the electrical signal error (2) 5.8 electrical signal frequency indication error (2) 5.9 latency indication error (2) Calibration Condition 6 (2) 6.1 environmental conditions (2) 6.2 standards and other measuring equipment (2) 7 calibration items and calibration methods (3) 7.1 appearance and function check (3) 7.2 flash intensity setpoint error (3) 7.3 flash duration (3) 7.4 flash stimulator background brightness setting error (3) 7.5 Graphics Contrast (3) 7.6 Graphics average brightness setting error (4) 7.7 Graphics stimulator luminance uniformity (4) 7.8 shows the magnitude of the electrical signal error (4) 7.9 Indication error frequency signals (5) 7.10 latency indication error (5) 8 calibration results expression (6) 8.1 Calibration records (6) 8.2 Calibration process results (6) 9 Recalibration interval (6) Appendix A visual electrophysiology instrument calibration original records (recommended) formatting styles (7) Appendix B calibration certificate within the page (recommended) formatting styles (10) Appendix C Measurement Uncertainty Example (14)

Introduction

This specification is for the measurement of technical regulations visual electrophysiology instrument calibration making. Preparation of this specification to JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001-2011 "common measurement terms and definitions" JJF 1059.1-2012 "Evaluation and Expression of Uncertainty in Measurement" as the basis and foundation, with reference to the ISCEV (2003) "Clinical Visual electrophysiological stimulation and recording parameters Calibration Guide" (Guidelinesforcalibrationofstimulusand recordingparametersusedinclinicalelectrophysiologyofvision) regulations. This specification is the first release. Calibration Specification for visual electrophysiology

1 Scope

This instruction applies to visual electrophysiology instrument calibration clinical use. 2. References This specification refers to the following documents. ISCEV (2003) "clinical visual electrophysiological stimulation and recording parameters Calibration Guide" (Guidelinesforcali- brationofstimulusandrecordingparametersusedinclinicalelectrophysiologyofvision) For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 terminology and units of measurement

3.1 Graphics average luminance meanluminanceofpattern The average of the graphic form of the highest brightness and the lowest brightness, unit. candela per square meter, symbol. cd/m2. 3.2 Graphics contrast patterncontrast Drawing light grid brightness and brightness contrast dark grid, expressed as a percentage. 3.3 brightness uniformity luminanceuniformity Graphics stimulator full brightness uniformity of display when expressed as a percentage. 3.4 flash intensity flashintensity Instantaneous flash of brightness integrated value time unit. seconds candela per square meter, symbol. cd · s/m2. 3.5 flash duration flashduration Single flash duration, unit. milliseconds symbol. ms. 3.6 latency latency Eye irritation from the received light signal to an electrical signal characteristic between the time delays, unit. milliseconds symbol. ms.

4 Overview

Visual electrophysiology instrument is one kind of electrophysiological signals measured by the human visual system after light stimuli to diagnose Instrument of visual function. Visual electrophysiology instrument to the human eye to light stimulation signal emitted by the stimulator while collecting electrode by the human visual system Biological signals generated by the electrical signal amplification and processing after recording and display, providing for clinical visual function Medical diagnosis. Visual electrophysiology instrument by the flash stimulation, graphics stimulator, electrode, signal acquisition, data processing Operating system and the display system.

5 Metrological characteristics

5.1 flash intensity settings error No more than ± 10%.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1543-2015_English be delivered?

Answer: Upon your order, we will start to translate JJF 1543-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1543-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1543-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.