Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1539-2015 English PDF

US$419.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1539-2015: Calibration Specification for Silicate Analyzers
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1539-2015419 Add to Cart 3 days Calibration Specification for Silicate Analyzers Valid

Similar standards

JJG 879   JJF 1106   JJG 810   JJF 1544   JJF 1546   JJF 1543   

Basic data

Standard ID: JJF 1539-2015 (JJF1539-2015)
Description (Translated English): Calibration Specification for Silicate Analyzers
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A60
Classification of International Standard: 17.180
Word Count Estimation: 18,152
Date of Issue: 2015-06-15
Date of Implementation: 2015-09-15
Quoted Standard: JJF 1094; GB/T 6682; GB/T 12149; DL/T 677
Regulation (derived from): AQSIQ Announcement 2015 No.72
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This Standard applies to silicate analyzer calibration.

JJF 1539-2015: Calibration Specification for Silicate Analyzers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Silicate analyzer calibration specification) People's Republic of China National Metrology Technical Specifications Silicate analyzer calibration specification Issued on. 2015-06-15 2015-09-15 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Silicate analyzer calibration specification Focal point. the National Technical Committee on Optical metrology Main drafting unit. Liaoning Provincial Institute of Metrology China Testing Technology Research Institute Participated in the drafting unit. Shenyang Metrology hospital Xinjiang Institute of Metrology Dalian City Electronics Co., Ltd. This specification committee commissioned by the National Optical measurement technology is responsible for interpreting The main drafters of this specification. Aiming Ze (Liaoning Provincial Institute of Metrology) Li Xiaobin (China Testing Technology Research Institute) Zhang Mei (Liaoning Provincial Institute of Metrology) Drafters participate. Xiao Zhe (Liaoning Provincial Institute of Metrology) Zhang Gong (Shenyang Metrology Institute) Bai Xu (Xinjiang Institute of Measurement and Testing) Golden People (Dalian City Electronics Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Overview (1) 4 Metrological characteristics (2) 4.1 Instrument indication error (2) 4.2 Repeatability measuring instrument (2) 4.3 Instrument stability (2) 4.4 Instrument 24h run stability (2) 4.5 Instrument phosphate anti-interference performance (2) Calibration Condition 5 (2) 5.1 Calibration Environment (2) 5.2 standard devices and other equipment (2) 6 calibration items and calibration methods (3) 6.1 Calibration before the test (3) 6.2 Instrument indication error (3) 6.3 instrument measurement repeatability (3) 6.4 Instrument stability (4) 6.5 Instrument 24h run stability (4) 6.6 Instrument phosphate anti-interference performance (4) 7 Calibration Results The expression (4) 8 Recalibration interval (5) Appendix A calibration reagent and solution preparation method (6) Appendix B recommended calibration record format (7) Appendix C Recommended calibration certificate-page format (9) Appendix D Evaluation of Uncertainty in Measurement Example (10)

Introduction

This specification based JJF 1071-2010 "National Calibration Specifications writing rules", JJF 1001 "universal metering Terms and definitions ", JJF 1059.1-2012" Evaluation and Expression of Uncertainty in Measurement ", and referring to (part) GB/T 12149-2007 "industrial circulating cooling water and boiler water Determination of Silicon", DL/T 677-2009 "hair Power line chemical instrumentation test procedures "requirement developed. This specification calibrated main items are. --- Instrument indication error; --- Instrument measurement repeatability; --- Instrument stability; --- Instrument 24h operational stability; --- Instrument phosphate anti-interference performance. The specification for the first time to develop. Silicate analyzer calibration specification

1 Scope

This instruction applies to silicate analyzer calibration. 2. References This specification references the following documents. JJF 1094 measuring instrument characteristics evaluation Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 12149 Determination of industrial circulating cooling water and boiler water in silicon DL/T 677 meter inspection of chemical plants online For dated references, only the dated edition applies to this specification; undated reference documents Member, the latest edition (including any amendments) applies to this specification.

3 Overview

Silicate analyzer (hereinafter referred to as the instrument) is used to measure the water content of silicate analysis instrument that measures primary Water soluble silicon processing under certain conditions, the reagent reacts and color, according to Lambert - Beer law, when Bundle of parallel monochromatic light through the light-absorbing substance containing the colored solution, part of the light is absorbed when the absorbing layer thickness is not Varying proportional to the concentration and the absorbance of light-absorbing substance by photoelectric detection device converts the optical signal into an electrical signal by After the microprocessor, the display silicate content. Lambert - Beer law mathematical expression is. A = -lg I0 = - lgT = klc Where. A --- absorbance substances; I --- transmitted monochromatic light intensity; Monochromatic light intensity I0 --- incident; T --- substance transmittance; Extinction coefficient k --- substances; l --- analyte optical path substances; c --- concentration of the substance. Instruments mainly by the light source system, the spectrometer, the sample chamber, the detection system, etc., see Schematic figure 1.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1539-2015_English be delivered?

Answer: Upon your order, we will start to translate JJF 1539-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1539-2015_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1539-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.