HJ 655-2013 PDF EnglishUS$170.00 · In stock · Download in 9 seconds
HJ 655-2013: Technical specifications for installation and acceptance of ambient air quality continuous automated monitoring system for PM10 and PM2 - 5 Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure Status: Valid
Similar standardsHJ 655-2013: Technical specifications for installation and acceptance of ambient air quality continuous automated monitoring system for PM10 and PM2 - 5---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/HJ655-2013 National Environmental Standard of the People’s Republic of China Technical specification for installation and acceptance of ambient air quality continuous automated monitoring system for PM10 and PM2.5 Issued on: JULY 30, 2012 Implemented on: AUGUST 1, 2013 By. Ministry of Environment Protection Ministry of Environmental Protection of People’s Republic of China Announcement In order to implement the “Environmental Protection law of PRC”; protect the environment, ensure human health, and regulate environmental air quality monitoring, “Technical Requirements and Detection Methods of Technical Requirements and Detection Methods of Continuous Automatic Monitoring System for Ambient Air Particles (PM10 and PM25)” and other five standards are approved as the environmental protection standard, and they are issued. The standard name and their number are as follows. 1.Technical Requirements and Detection Methods of Continuous Automatic Monitoring System for Ambient Air Particles (PM10 and PM25) (HJ 653-2013); 2.Technical Requirements and Detection Methods of Continuous Automatic Monitoring System for Ambient Air Gaseous Pollutants (SO2, NO2, O3, CO) (HJ 654-2013); 3.Technical Requirements and Detection Methods of Samplers for Ambient Air Particles (PM10 and PM25) (HJ 93-2013); 4.Security and Technical Specifications for Acceptance of Continuous Automatic Monitoring System for Ambient Air Particles (PM10 and PM25) (HJ 655-2013); 5.Security and Technical Specifications for Acceptance of Continuous Automatic Monitoring System for Ambient Air Gaseous Pollutants (SO2, NO2, O3, CO) (HJ 193-2013); 6.Technical Requirements for Manual Monitoring Method of Ambient Air Particles PM25 (Gravimetric Method) (HJ 656-2013). From the date of implementation of the above standards, the following environmental protection standards approved and issued by the previous State Environmental Protection Administration are annulled; the standard name and their number are as follows. 1.Technical Requirements and Detection Methods of Samplers for PM10 (HJ/T 93-2003) 2.Technical Requirements for Ambient Air Quality Continuous Automatic Monitoring (HJ/T 93-2005) Hereby it is announced. Ministry of Environmental Protection July 30, 2013 Table of ContentsPREFACE... 5 1.Scope of application... 6 2.Standard for quotations and references... 6 3 Terms and definitions... 6 4.The constitution and theory of the system... 7 5.Installation... 8 6.Debugging... 13 7.Trial run... 20 8.Acceptance check... 21 Appendix A... 25 Appendix B... 26 Appendix C... 34 Appendix D... 36 Translation References and Original Chinese Documents... 40 PREFACE In order to implement the Environmental Protection Law of the People's Republic of China, and The Law of the People's Republic of China on the Prevention and Control of Atmospheric Pollution, to implement Ambient Air Quality Standards (GB 309-2012), and to regulate the installation and acceptance of the ambient air quality continuous automated monitoring system for particles in ambient air (hereinafter it will be simply called PM10 and PM2.5 continuous automated monitoring system), this Standard is formulated. This Standard regulates the technical standard for constitution, installation, debugging, trail running and the acceptance of particles (PM10 and PM2.5) of the ambient air continuous automated monitoring system. This Standard is the amendment to some contents of the Technical Specification of Environmental Air Quality Automatic Monitoring (HJ/T193-2005). This Standard was released firstly in 2005 and this is the first revision. The main contents of the amendments include the following. - Clarifying the technical requirements of the installation and acceptance of PM10 continuous monitoring system; - Adding up the technical requirements of the installation and acceptance of PM2.5 continuous monitoring system. Since its date of implementation, the contents about the installation and acceptance of PM continuous monitoring system in Automated methods for ambient air quality monitoring (HJ/T193-200) shall be abolished. The appendix A of this Standard is normative and appendix B, C and D are informative. The drafting organization of this Standard. China National Environmental Monitoring Centre This Standard was approved on July 30, 2013 by Environmental Protection Department This Standard shall be implemented from August 1, 2013 and shall be explained by Environmental Protection Department. Technical specifications for installing and acceptance of ambient air quality continuous automated monitoring system for PM10 and PM2.5 1.Scope of application This Standard regulates the technical standard for constitution, installation, debugging, trail running and the acceptance of particles (PM10 and PM2.5) of the ambient air continuous automated monitoring system. This Standard is applicable for the installation and acceptance for the ambient air quality continuous automated monitoring system for PM10 and PM2.5. 2.Standard for quotations and references The articles contained in the following documents have become part of this Standard when they are quoted herein. For the undated documents so quoted, the latest editions shall be applicable to this Standard. GB 3095-2012 Ambient air quality standard GB 50168 Code for construction and acceptance of cable levels electric equipment installation engineering GB/T 17214.1 Industrial-process measurement and control Working conditions Chapter 1.climate conditions HJ 618 Measurement of ambient air PM10 and PM2.5 Gravimetric method HJ/T 212 Systematic data transmission standard for automatic monitoring of online sources of pollution YD 5098 Specification design for lightening and grounding of telecom base station3 Terms and definitionsThe following terms and definitions shall be applied to this Standard. 3.1 Ambient air quality continuous monitoring The process that the continuous monitoring instruments are applied for the collection, handling and analysis of the continuous samples, at the monitoring sites. 3.2 Ambient air quality manual monitoring The process that the ambient air samples within a period of time shall be collected and then applied the collected samples for the analysis and processing of analytic instruments in the labs, at the monitoring sites. 3.3 Particulate matter (PM10) It refers to the particles of which the dynamic equivalent diameter is equal to or less than 10 μm, and it can also be called as inhalable particulate matters (IP). 3.4 Particulate matter (PM2.5) It refers to the particles of which the dynamic equivalent diameter is equal to or less than 2.5 μm and it can also be called as fine particulate matter. 3.5 Particle separate device It refers to the device that can separate different particles with various sizes. 3.6 Standard state It refers to the state when the temperate reaches 273.15k and the pressure is 101.325 kPa. The densities of the pollutants in this Standard are under standard states. 3.7 Reference method The standard method released by the country. 4.The constitution and theory of the system 4.1 The constitution of the system The continuous monitoring system of PM10 and PM2.5 consists of the following, namely the sample collection unit, sample measuring unit, the collection and transmission unit of the data and other accessory equipment. 4.1.1 Sample collection unit The sample collection unit is made up by the sampling entrance, cutting machine and sampling tube which will cut and separate the ambient particles and transmit the target particles to the sample measuring unit. 4.1.2 Sample measuring unit Sample measuring unit will measure the collected ambient air sample PM10 and PM 2.5. 4.1.3 Collection and transmission unit of... ......Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al. Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of English version of HJ 655-2013 be delivered?Answer: The full copy PDF of English version of HJ 655-2013 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.Question 2: Can I share the purchased PDF of HJ 655-2013_English with my colleagues?Answer: Yes. The purchased PDF of HJ 655-2013_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- HJ 655-2013 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.How to buy and download a true PDF of English version of HJ 655-2013?A step-by-step guide to download PDF of HJ 655-2013_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).Step 2: Search keyword "HJ 655-2013". Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart. Step 4: Select payment option (Via payment agents Stripe or PayPal). Step 5: Customize Tax Invoice -- Fill up your email etc. Step 6: Click "Checkout". Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively. Step 8: Optional -- Go to download PDF. Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice. See screenshots for above steps: Steps 1~3 Steps 4~6 Step 7 Step 8 Step 9 |