HJ 1118-2020 English PDFUS$1289.00 · In stock
Delivery: <= 7 days. True-PDF full-copy in English will be manually translated and delivered via email. HJ 1118-2020: Technical specification for application and issuance of pollutant permit - Bulk oil terminal and oil filling station Status: Valid
Basic dataStandard ID: HJ 1118-2020 (HJ1118-2020)Description (Translated English): Technical specification for application and issuance of pollutant permit - Bulk oil terminal and oil filling station Sector / Industry: Environmental Protection Industry Standard Word Count Estimation: 56,568 Date of Issue: 2020-03-04 Date of Implementation: 2020-03-04 Issuing agency(ies): Ministry of Ecology and Environment HJ 1118-2020: Technical specification for application and issuance of pollutant permit - Bulk oil terminal and oil filling station---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Technical specification for application and issuance of pollutant permit - Bulk oil terminal and oil filling station National Environmental Protection Standards of the People's Republic of China Technical specifications for pollutant discharge permit application and issuance Oil storage, gas station 2020-03-04 released 2020-03-04 Implementation Issued by the Ministry of Ecology and Environment Table of contentsForeword...ii 1.Scope of application...1 2.Normative references...1 3.Terms and definitions...2 4.Oil storage depot sewage unit...3 5.Gas station sewage unit...21 Appendix A (informative appendix) Basic information table of oil depot sewage disposal unit...31 Appendix B (informative appendix) Default calculation parameters for permitted emissions of unorganized volatile organic compounds from storage tanks...36 Appendix C (Informative Appendix) Reference Table of Available Technologies for Pollution Treatment Facilities of Oil Storage Pollution Units...37 Appendix D (Informative Appendix) Reference Table of Environmental Management Ledger Records of Oil Storage Sewage Units...38 Appendix E (informative appendix) Form of implementation report of pollutant discharge permit for oil depot pollutants...41 Appendix F (Informative Appendix) Reference Table for Pollution Prevention and Control of Gas Station Discharge Units...47 Appendix G (Informative Appendix) Reference Table of Environmental Management Ledger Records of Gas Station Sewage Units...48 Appendix H (informative appendix) Gas station pollutant discharge unit discharge permit execution report form...50ForewordIn order to implement the "Environmental Protection Law of the People's Republic of China", "The Air Pollution Prevention Law of the People's Republic of China", "China The Water Pollution Prevention and Control Law of the People’s Republic of China, the Soil Pollution Prevention and Control Law of the People’s Republic of China, and other laws and regulations, and the Office of the State Council Department’s Notice on Printing and Distributing the Implementation Plan for the Control of Pollutant Discharge Permit System (Guobanfa [2016] No. 81) and the "Pollution Permit Manageable Measures (for Trial Implementation)" (Ministry of Environmental Protection Order No. 48), improve the technical support system for pollutant discharge permits, guide and regulate This standard is formulated for the application and issuance of pollutant discharge permits for the pollutant discharge units of Fan oil storage depots and gas stations. This standard specifies the basic requirements for filling in the application and issuance of the pollutant discharge permit for oil storage depots and gas stations. Determination of allowable emission limits, actual emission accounting and compliance determination methods, as well as self-monitoring, environmental management accounts and pollution permits Environmental management requirements such as the certifiable implementation report put forward feasible technical requirements for pollution prevention and control. Appendix A to Appendix H of this standard are informative appendices. This standard is issued for the first time. This standard is formulated by the Department of Environmental Impact Assessment and Emission Management and the Department of Regulations and Standards of the Ministry of Ecology and Environment. Drafting organizations of this standard. Environmental Engineering Evaluation Center of Ministry of Ecology and Environment, Beijing Municipal Research Institute of Environmental Protection, Qingdao Ou Seth Environmental and Safety Technology Co., Ltd., China National Petroleum Corporation Planning Institute, Qingdao Zhongshi Dahuan Environment and Security Technology Center Co., Ltd. This standard was approved by the Ministry of Ecology and Environment on March 04, 2020. This standard will be implemented on March 04, 2020. This standard is interpreted by the Ministry of Ecology and Environment. Sewage discharge permit application and issuance of technical specifications for oil storage depots and gas stations1 Scope of applicationThis standard specifies the basic requirements and permits for the application and issuance of pollution discharge permits for oil storage depots and gas stations. Determination of emission limit, actual emission calculation and compliance determination methods, as well as self-monitoring, environmental management ledger and pollution permit Environmental management requirements such as the implementation report of the certificate, put forward feasible technical requirements for pollution prevention and control. This standard is applicable to guide oil storage depots and gas station sewage disposal units to fill in relevant applications on the national pollution discharge permit management information platform The information is also applicable to guide the approval and issuance department to review and determine the pollution discharge permit requirements of oil storage depots and gas stations. This standard is applicable to oil storage depots (including the oil storage depot area supporting the wharf), water pollutants discharged by gas station sewage units, and atmospheric Pollutant discharge permit management. Permits for the discharge of water pollutants and air pollutants from sewage units that store liquid organic chemicals Can be managed and implemented by reference. In the oil storage depots and gas station pollutant discharge units, the production facilities and equipment that implement the "Boiler Air Pollutant Emission Standard" (GB 13271) The discharge port is applicable to the "Boiler with Technical Specification for Pollution Discharge License Application and Issuance" (HJ 953). Oil storage depots and gas stations that discharge industrial waste water, exhaust gas, or toxic and harmful pollutants specified by the state that are not specified in this standard Other pollution-producing facilities and discharge outlets of pollutant discharge units shall be implemented in accordance with the "General Rules for the Application and Issuance of Pollutant Discharge Permits" (HJ 942).2 Normative referencesThe content of this standard refers to the terms in the following documents. For undated reference documents, the effective version is applicable to this standard. GB 8978 Integrated Wastewater Discharge Standard GB 13271 Boiler Air Pollutant Emission Standard GB 14554 Emission Standard of Odor Pollutants GB 16297 Comprehensive Emission Standard of Air Pollutants GB 18597 Pollution Control Standard for Hazardous Waste Storage GB 20950 Emission Standard of Air Pollutants for Oil Storage Depots GB 20952 Gas Station Air Pollutant Emission Standard GB 37822 Unorganized emission control standard of volatile organic compounds GB/T 4754-2017 Classification of National Economic Industries GB/T 16157 Determination of particulate matter in exhaust from stationary sources and sampling method for gaseous pollutants HJ 38 Determination of total hydrocarbons, methane and non-methane total hydrocarbons in stationary pollution sources gas chromatography HJ/T 55 Technical Guidelines for Monitoring Unorganized Emissions of Air Pollutants HJ 91.1 Technical Specification for Wastewater Monitoring HJ/T 373 Fixed pollution source monitoring quality assurance and quality control technical specifications (trial implementation) HJ/T 397 Fixed source exhaust gas monitoring technical specification HJ 493 Technical Regulations for Storage and Management of Water Quality Samples HJ 494 Technical Guide for Water Quality Sampling HJ 495 Technical Regulations for Water Quality Sampling Scheme Design HJ 521 Wastewater Discharge Law Code (Trial) HJ 604 Determination of Ambient Air Total Hydrocarbons, Methane and Non-Methane Total Hydrocarbons Direct Sampling-Gas Chromatography HJ 608 Code Rules for Pollutant Discharge Units HJ 733 Leakage and open liquid level emission of volatile organic compounds detection technology guide HJ 819 General Rules of Technical Guidelines for Self-monitoring of Pollutant Discharge Unit HJ/T 91 Technical specification for surface water and sewage monitoring HJ 942 General Rules of Technical Specifications for Pollution Discharge Permit Application and Issuance HJ 944 General Rules of Technical Specification for Environmental Management Ledger and Pollution Discharge Permit Implementation Report (Trial) HJ 953 Sewage discharge permit application and issuance of technical specifications for boilers "List of Classification Management of Discharge Permits for Fixed Pollution Sources" "Administrative Measures for Pollution Discharge Permits (for Trial Implementation)" (Ministry of Environmental Protection Order No. 48) "Technical Requirements for Standardized Remediation of Sewage Outlets" (Huajian [1996] No. 470) "Guidelines for the Investigation of VOCs Pollution Sources in the Petrochemical Industry" (Huanban [2015] No. 104) "Technical Guidelines for the Prevention and Control of Groundwater Pollution in Gas Stations (Trial)" (Huanban Shuitihan [2017] No. 323) "Comprehensive Treatment Plan for Volatile Organic Compounds in Key Industries" (Huan Taiqi [2019] No. 53)3 Terms and definitionsThe following terms and definitions apply to this standard. 3.1 Bulk oil terminal pollutant emission units Refers to the receiving and dispatching (including storage) of crude oil, raw materials, etc., which are composed of oil storage tanks and are sent and received by means of tank cars, railway tank cars, ships or pipelines. The pollutant discharge unit of oil products such as oil products (except the storage places of oil products such as crude oil and refined oil products in the production enterprise). 3.2 oil filling station pollutant emission units Refers to a pollutant discharge unit that is composed of oil storage tanks, fuel dispensers, and oil guns to add refined oil to motor vehicles. 3.3 Petroleum products Refers to gasoline, kerosene, diesel and other ethanol gasoline and biodiesel that meet the national product quality standards and have the same purpose Wait for alternative fuels. 3.4 key management pollutant discharge units Refers to the pollutant discharge units that are included in the "List of Classified Management of Permits for Discharge of Fixed Pollution Sources". 3.5 simplified management pollutant discharge units Refers to the pollutant discharge units that are included in the "List of Classification Management of Permits for Discharge of Fixed Pollution Sources" to simplify management. 3.6 volatile organic compounds Organic compounds that participate in atmospheric photochemical reactions, or organic compounds determined in accordance with relevant regulations. This standard uses "non- Methane Total Hydrocarbons (NMHC)” is used as a comprehensive control index for volatile organic compounds emissions from exhaust pipes and corporate boundaries. 3.7 volatile organic liquid Any organic liquid that can release volatile organic compounds into the atmosphere and meet one of the following conditions. (1) At 20 ℃, the real vaporization A single-component organic liquid with a pressure greater than or equal to 0.3 kPa; (2) At 20 ℃, the true vapor pressure of the mixture is greater than or equal to An organic liquid whose total mass of 0.3 kPa components is greater than or equal to 20%. 3.8 permitted emission limits Refers to the maximum discharge concentration (rate) and discharge volume of pollutants that are allowed to be discharged by the pollutant discharge unit specified in the pollution discharge permit. 3.9 special periods Refers to the environmental quality compliance plan and other relevant environmental management regulations formulated by local governments The pollutant discharge situation has special requirements for the time period, including the response period of heavy pollution weather and the winter protection period.4 Sewage discharge unit of oil storage depot4.1 Requirements for basic information of pollutant discharge units 4.1.1 General principles The pollutant discharge unit shall fill in the corresponding information in the national pollutant discharge permit management information platform application system in accordance with the requirements of this standard. fill If it is not included in the reporting system, the local ecological environment authority requires it to be reported, or the pollutant discharge unit thinks it needs to be reported, it can do so by itself add content. Local ecological and environmental authorities at or above the municipal level with districts may increase the The content specified in the permit, and fill in the “local ecological environment with the right to issue” in the application system of the national pollution discharge permit management information platform The management content added by the environmental authorities" column. 4.1.2 Basic situation of pollutant discharge units The basic information of the pollutant discharge unit includes unit name, license management category, postal code, industry category, whether it is in operation and Production date, latitude and longitude of the production and operation site, whether the location is an environmentally sensitive area (such as the key control area of the atmosphere, total phosphorus and total nitrogen control Industrial park), whether it is located in the industrial park and the name of the industrial park to which it belongs, the environmental impact assessment approval number (record number), and the place The document number of the government's identification or filing of illegal projects, the document number of the distribution plan of the main pollutant total control index, Total organic matter (VOCs) indicators, total indicators of other pollutants (if any), etc. When reporting and selecting the industry category, select GB/T 4754-2017 G 5941 Oil and Gas Storage. 4.1.3 Main products and production capacity 4.1.3.1 General principles Fill in the basic information with the main project, production facilities, facility parameters, production facility numbers, material names, and others. 4.1.3.2 Main project The main project of the oil storage depot sewage unit is divided into storage tank area, loading and unloading area and public auxiliary facilities. Fill in the design storage capacity (ten thousand cubic meters), The number of storage tanks, the number of crane positions, the number of sealing points of equipment and pipeline components through which the volatile organic flows, and the scale of sewage treatment facilities are shown in Table 1. 4.1.3.3 Production facilities and facility parameters The type and quantity of equipment and pipeline assembly sealing points (quantity ≥2000) through which the volatile organic flows pass, see Table A.1 in Appendix A for details. Volatile organic liquid storage tank tank type, nominal volume, inner diameter, tank height, storage material name, material storage temperature and Design annual turnover (if there is no design annual turnover, fill in the average value of the actual turnover in the past three years), etc., see appendix for details Table A.2 in A, detailed parameters can be optional fill in Table A.3 ~ Table A.5 in Appendix A. The parameters of the volatile organic liquid loading facility include the name of the loaded material, the designed annual loading capacity, the loading temperature and the loading form (fire Vehicles/cars/ships/barges), see Table A.6 in Appendix A for details. Other production facilities are optional. 4.1.3.4 Production facility number The pollutant discharge unit can fill in the internal production facility number. If the pollutant discharge unit does not have the internal production facility number, it will be processed according to HJ 608 Number and fill in. 4.1.3.5 Material name Fill in the name of the main materials, including crude oil, gasoline, ethanol gasoline, kerosene, diesel, biodiesel, fuel oil, naphtha Oil, wax oil, residual oil, etc. 4.1.3.6 Other If the pollutant discharge unit needs to explain, it can fill in the report. 4.1.4 Main auxiliary materials 4.1.4.1 General principles Report the auxiliary materials added in the process of wastewater treatment and waste gas treatment. The toxic and harmful substances in the auxiliary materials and their proportion are required. 4.1.4.2 Name Fill in the name of the main auxiliary materials, including activated carbon, catalyst, etc. 4.1.4.3 Design annual usage Fill in the design annual usage. If there is no designed annual usage, the report shall be based on the average of the actual usage in the past three years. 4.1.4.4 Other If the pollutant discharge unit needs to explain, it can fill in the report. 4.1.5 Pollution production and discharge nodes, pollutant projects and pollution control facilities 4.1.5.1 General principles Waste gas production and discharge nodes, pollutant projects and pollution control facilities include production and discharge links, pollutant projects, emission forms, Pollution control facilities and processes, whether it is feasible technology, pollution control facility parameters, pollution control facilities and discharge port numbers, discharge Whether the vent setting is standardized and the type of discharge port, etc. Wastewater production and discharge nodes, pollutant projects and pollution treatment facilities include waste water categories, pollutant projects, waste water destination, pollution Pollution control facilities and processes, whether it is a feasible technology, pollution control facility parameters, emission methods, emission destinations and emission rules, Pollution control facilities and discharge port numbers, whether the discharge ports are set up in a standard manner, and the types of discharge ports, etc. 4.1.5.2 Exhaust gas a) Production and discharge links, pollutant projects and pollution control facilities The contents of production and discharge links, pollutant items, discharge forms, and pollution control facilities are shown in Table 2.Contents not listed in the table The pollutant discharge unit shall fill in the report by itself. The pollutant items are determined according to GB 14544, GB 16297, GB 20950, and GB 37822.Ground If there are stricter requirements in the emission standards of the Party’s pollutants, the regulations shall prevail. 4.2 Corresponding discharge outlets and permitted discharge limits for production and discharge nodes 4.2.1 Discharge outlets and implementation standards 4.2.1.1 Exhaust gas Exhaust gas discharge outlets should be filled with the geographical coordinates of the discharge outlet, the height of the exhaust cylinder, national or local pollutant discharge Promise more stringent emission limits. 4.2.1.2 Wastewater For direct waste water discharge outlets, the geographic coordinates of the discharge outlets, discharge rules, the names and codes of the corresponding sewage outlets into the river, and the Natural water body information, geographic coordinates of the receiving natural water body and the implementation of national or local pollutant discharge standards; wastewater indirect The discharge outlet shall fill in with the geographical coordinates of the discharge outlet, the discharge rule, the information of the receiving sewage treatment plant and the......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of HJ 1118-2020_English be delivered?Answer: Upon your order, we will start to translate HJ 1118-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 7 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of HJ 1118-2020_English with my colleagues?Answer: Yes. The purchased PDF of HJ 1118-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |