GBZT316.2-2018 English PDFUS$119.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GBZT316.2-2018: Determination of lead in blood -- Part 2: Inductively coupled plasma mass spectrometry method Status: Valid
Basic dataStandard ID: GBZ/T 316.2-2018 (GBZ/T316.2-2018)Description (Translated English): Determination of lead in blood -- Part 2: Inductively coupled plasma mass spectrometry method Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: C60 Word Count Estimation: 6,636 Date of Issue: 2018-08-16 Date of Implementation: 2019-01-01 Regulation (derived from): State-Health-Communication (2018) No.14 Issuing agency(ies): National Health and Family Planning Commission GBZ/T 316.2-2018: Determination of lead in blood -- Part 2: Inductively coupled plasma mass spectrometry method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Determination of lead in blood - Part 2. Inductively coupled plasma mass spectrometry method ICS 13.100 C 52 National Occupational Health Standards Published on.2018 - 08 - 16 2019 - 01 - 01 implementation Determination of lead in blood Part 2. Inductively coupled plasma mass spectrometry Determination of lead in blood- Part 2. Inductively coupled plasma mass spectrometry method National Health and Wellness Committee of the People's Republic of China ForewordThis standard is formulated in accordance with the Law of the People's Republic GBZ /T 316-2018 "Determination of lead in blood" is divided into three parts. -- Part 1. Graphite furnace atomic absorption spectrometry; -- Part 2. Inductively coupled plasma mass spectrometry; -- Part 3. Atomic Fluorescence Spectrometry. This part is the second part of GBZ /T 316. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This standard was drafted. China Center for Disease Control and Prevention, Occupational Health and Poison Control Institute, Jiangsu Provincial Center for Disease Control and Prevention, Guangdong Provincial Institute of Occupational Disease Prevention and Control and Shandong Institute of Occupational Disease Prevention and Control. The main drafters of this standard. Ding Chunguang, Zhu Alcohol, Zhang Aihua, Xu Guang, Yan Huifang. Determination of lead in blood - Part 2. Inductively coupled plasma mass spectrometry1 ScopeThis part of GBZ /T 316 specifies inductively coupled plasma mass spectrometry for lead in blood. This section applies to the determination of lead in the blood of occupational contacts.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document. General rules for biological monitoring of GBZ /T 295 occupational population3 PrincipleBlood samples (hereinafter referred to as blood samples) were directly diluted with 0.5% nitric acid-0.01% Triton diluent, using Lu (Lu) as an internal standard. Inductively coupled plasma mass spectrometry was used to determine lead (m/z. 206, 208) content in standard mode.4 instruments4.1 Covered polyethylene plastic bottle, 100 mL. 4.2 Polyethylene centrifuge tube, 15 mL. 4.3 Volumetric flask, 10 mL. 4.4 Micropipettes with a range of 100μL to 1000μL. 4.5 Inductively coupled plasma mass spectrometer.5 reagent5.1 Deionized water. 5.2 Nitric acid. ρ20=1.42g/mL, excellent grade pure. 5.3 Nitric acid solution. 0.5% (volume fraction). 5.4 Triton X-100, analytical grade. 5.5 Triton X-100 solution, 1% (volume fraction). 5.6 Diluent. 10 mL Triton X-100 solution (1%) was placed in 1 L nitric acid solution (0.5%). 5.7 Internal standard solution. 镥 unit standard solution, diluted with a 0.5% (volume fraction) nitric acid solution to a 10.0 μg/L solution before use. 5.8 Standard solution. lead single element standard solution, diluted with standard solution of 0.5% (volume fraction) nitric acid solution to 10.0mg/L before use. liquid. 6 Sample collection, transportation and storage According to GBZ /T 295. The collected samples and sample blanks are placed in a clean container for refrigerated transport. The sample can be stored for half a year at -20 °C.7 Analysis steps7.1 Instrument operation. a) Cooling gas flow rate. 12.5 L/min b) Auxiliary gas flow rate. 0.7 L/min c) Atomizing gas flow rate. 0.92 L/min d) Peristaltic pump speed. 30r/min e) Nebulizer temperature. 3 ° C f) Online internal standard. 10.0μg/L镥 7.2 Sample Handling. Remove the chilled blood sample and return to room temperature. After fully shaking and mixing, transfer 0.50 mL of blood sample to 15 mL. In a polyethylene centrifuge tube, 4.50 mL of diluent was added, and the mixture was shaken and measured. 7.3 Treatment of sample blank. 2.0 mL water was taken with a blood collection needle and placed in a blood collection tube, shaken, and the remaining treatment steps were the same as the sample. 7.4 Configuration and determination of the standard curve. dilute the standard solution with nitric acid solution to mark 0.0, 1.0, 5.0, 10.0, 50.0, 100 μg/L Quasi-series. Determine each standard solution, and simultaneously measure the internal standard solution, the ratio of the response value of the standard series lead to the internal standard response value to the corresponding lead Concentration (μg/L) plots the standard curve or calculates the regression equation. 7.5 Sample determination. After the sample is processed, the sample solution and the sample blank solution are determined by the operating conditions of the measurement standard series; Or the regression equation to obtain the concentration of lead (μg/L).8 calculationCalculate the concentration of lead in the blood sample according to formula (1). C = 10C0 (1) In the formula. C--the concentration of lead in blood, in micrograms per liter (μg/L); 10--sample dilution factor; C0--The concentration of lead in the diluted blood sample obtained by the standard curve or regression equation (minus blank sample) in micrograms per liter (μg/L).9 Description9.1 The measurement range of this method is 0.7μg/L~1000μg/L, the detection limit of the method is 0.17μg/L, and the lower limit of the method is 0.7μg/L. The standard deviation averaged 0.6% to 2.43%; the average recovery of the method was 86%. 9.2 With 镥 as the internal standard, the interference of the substrate and the signal drift caused by the instrument are corrected. 9.3 The whole process of this experiment should be carried out in a clean area as much as possible to avoid the introduction of pollution from the external environment. 9.4 Quality control of the test process shall be carried out in accordance with the requirements of GBZ /T 295. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GBZT316.2-2018_English be delivered?Answer: Upon your order, we will start to translate GBZT316.2-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GBZT316.2-2018_English with my colleagues?Answer: Yes. The purchased PDF of GBZT316.2-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |