Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GBZ29327-2012 English PDF

US$799.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
GBZ29327-2012: Specification for 1000 kV reactor protection equipment
Status: Obsolete
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/Z 29327-2012799 Add to Cart 4 days Specification for 1000 kV reactor protection equipment Obsolete

Similar standards

GB/T 38953   GB/T 37155.2   GB/T 19826   GB/T 45648.2   GB/T 29327   GB/T 29323   

Basic data

Standard ID: GB/Z 29327-2012 (GB/Z29327-2012)
Description (Translated English): Specification for 1000 kV reactor protection equipment
Sector / Industry: National Standard
Classification of Chinese Standard: K45
Classification of International Standard: 29.240.99
Word Count Estimation: 20,213
Quoted Standard: GB/T 191; GB/T 2887-2011; GB/T 2900.17; GB/T 2900.49; GB/T 7261-2008; GB/T 9361-2011; GB/T 11287-2000; GB/T 14285-2006; GB/T 14537-1993; GB/T 14598.9-2010; GB/T 14598.10-2012; GB/T 14598.11-2011; GB/T 14598.13-2008; GB/T 14598.14-2010; GB/T 14598.16-2002;
Regulation (derived from): National Standards Bulletin No. 41 of 2012
Issuing agency(ies): Ministry of Health of the People's Republic of China
Summary: This standard specifies the 1 000 kV reactor protection of the basic technical requirements, test methods, inspection rules and the logo, packaging, transportation and storage requirements. The technical guidance document applies to 1 000 kv reactor prote

GBZ29327-2012: Specification for 1000 kV reactor protection equipment

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Specification for 1000 kV reactor protection equipment ICS 29.240.99 K45 People's Republic of China national standardization of technical guidance documents 1000kV reactor protection device technical requirements Posted on.2012-12-31 2013-06-01 Implementation General Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China China National Standardization Administration released Directory Foreword Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions 2 4 technical requirements 2 4.1 Environmental conditions 2 4.2 Rated electrical parameters 3 4.3 Power consumption 3 4.4 The main function of the entire device 3 4.5 The main technical performance of the device 4 4.6 overload capacity 6 4.7 Insulation performance 6 4.8 resistance to hot and humid performance 7 4.9 Electromagnetic Compatibility Requirements 7 4.10 DC power supply 8 4.11 static simulation, dynamic simulation 8 4.12 continuous power 8 4.13 Mechanical Properties 9 4.14 Structure, Appearance and Others 9 5 test methods 9 5.1 Test conditions 9 5.2 Technical performance test 9 5.3 temperature test 10 5.4 Storage, transport limits Ambient temperature test 10 5.5 power consumption test 10 5.6 overload test 10 5.7 Insulation test 11 5.8 damp heat test 11 5.9 Electromagnetic compatibility requirements of the test 11 5.10 DC power supply impact test 12 5.11 continuous power test 12 5.12 Mechanical Performance Test 12 5.13 Structure and appearance inspection 12 6 Inspection rules 12 6.1 Inspection Classification 12 6.2 factory inspection 12 6.3 type test 13 7 logo, packaging, transportation, storage 14 7.1 mark 14 7.2 Packaging 14 7.3 Transportation 14 7.4 Storage 14 8 other 15

Foreword

This instructional document has been drafted in accordance with the rules given in GB/T 1.1-2009. This guidance document is proposed by China Electrical Equipment Industry Association. This Guidance Document is governed by the National Technical Committee for Standardization of Relays and Protective Equipment (SAC/TC154). The drafting of the guidance of technical documents. State Power Dispatching and Telecommunication Center, China Electric Power Research Institute, Nanjing NARI insurance electrical Co., Ltd., State Grid Electric Power Research Institute, Xu Ji Electric Co., Ltd., Beijing Sifang Automation Co., Ltd., State Power Nanjing since Automation Co., Ltd., Hebei Province Power Dispatching and Communication Center, State Grid Corporation of UHV Construction, Xuchang smart grid equipment test Institute, Xuchang Cape Electrical Testing Institute. The main drafters of this guidance document are Lu Pengfei, Zhou Zexin, Zhan Rongrong, Wen Jifeng, Yu Gaowang, Tu Liming, Wang Feng, Liu Hua, Li Bin, Yao Zhiqing, Yu Fei, Liu Wen, Li Zhiyong, Yang Huixia, Zhu Bin, Zhang Xiling. 1000kV reactor protection device technical requirements

1 Scope

This Guidance Document stipulates the basic technical requirements, test methods, inspection rules and benchmarking of 1000kV reactor protective devices Log, packaging, transportation, storage requirements. This Guidance Document is applicable to the 1000kV reactor protection device (hereinafter referred to as the device) for design, manufacture, Test and application of the basis.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 191 Packaging - Pictorial signs General specifications for computerized premises GB/T 2887-2011 GB/T 2900.17 Electrotechnical terminology measuring relays GB/T 2900.49 Electrotechnical terminology Power system protection Basic test methods of relay protection and safety automatic device Computerized site safety requirements GB/T 9361-2011 GB/T 11287-2000 Electrical relays - Part 21. Vibration, shock, bump and earthquakes of measuring relays and protection devices Test Part 1. Vibration test (sine) Technical specifications for relay protection and safety automatic devices Shock and collision tests for measuring relays and protection equipment Measuring relays and protection equipment - Part 22-3. Electrical disturbance tests Radiated electromagnetic field resistance Scramble GB/T 14598.10-2012 Electrical relays - Part 22-4 - Electrical disturbance tests for measuring relays and protection devices Fast transient/burst immunity test GB/T 14598.11-2011 Measuring relays and protection equipment Part 11. Auxiliary power supply port voltage dips, short interruptions, Voltage changes and ripple GB/T 14598.13-2008 Electrical relays - Part 22-1 - Electrical disturbance tests for measuring relays and protection devices 1MHz burst immunity test GB/T 14598.14-2010 Measuring relays and protection equipment - Part 22-2 - Electrical disturbance tests Electrostatic discharge tests GB/T 14598.16-2002 Electrical relays - Part 25. Electromagnetic emission test of measuring relays and protection devices GB/T 14598.17-2005 Electrical relays - Part 22-6. Electrical disturbance tests for measuring relays and protection equipment Frequency-induced disturbances of conducted disturbances GB/T 14598.18-2012 Electrical relays - Part 22-5 - Electrical disturbance test waveforms for measuring relays and protection devices Surge immunity test GB/T 14598.19-2007 Electrical relays - Part 22-7 - Electrical disturbance test workers for measuring relays and protection devices Frequency immunity test Measuring relays and protection equipment - Part 27. Product safety requirements
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ29327-2012_English be delivered?

Answer: Upon your order, we will start to translate GBZ29327-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ29327-2012_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ29327-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.