Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GBZ21192-2007 English PDF

US$259.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GBZ21192-2007: Space and fixing dimensions for electricity energy meter
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/Z 21192-2007259 Add to Cart 3 days Space and fixing dimensions for electricity energy meter Valid

Similar standards

GB/T 15284   GB/T 17215.321   GB/T 34067.2   GB/T 26862   GB/T 17215.241   GB/T 17215.301   

Basic data

Standard ID: GB/Z 21192-2007 (GB/Z21192-2007)
Description (Translated English): Space and fixing dimensions for electricity energy meter
Sector / Industry: National Standard
Classification of Chinese Standard: N22
Classification of International Standard: 17.220.20
Word Count Estimation: 10,167
Date of Issue: 2007-11-14
Date of Implementation: 5/1/2008
Regulation (derived from): China National Standard Approval Announcement2007 No.12 (Total No.112)
Issuing agency(ies): Ministry of Health of the People's Republic of China
Summary: This standard specifies the size of the fixed installation AC power meter and dimensions. And the main dimensions terminals and terminals. The technical guidance document applies to installation in the reference frequency of 50 Hz (60 Hz) of the grid for the next wiring into AC power under the table to the other wiring energy meter reference to the use of this technical guidance documents.

GBZ21192-2007: Space and fixing dimensions for electricity energy meter

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
GB /Z 21192-2007 Space and fixing dimensions for electricity energy meter ICS 17.220.20 N22 National Standardization Technical Document of the People's Republic of China GB /Z21192-2007 Electric meter shape and installation size Released on.2007-11-14 General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China China National Standardization Administration issued

Content

Foreword I 1 Scope 1 2 Normative references 1 3 Terms and Definitions 1 4 Requirements 1 Appendix A (informative) The size of the electric energy meter is preferably 6 GB /Z21192-2007

Foreword

The development of this guidance technical document refers to some foreign standards, such as BS7856..1996 "Class 1 and 2 AC active energy meter design" Practical Specification, DIN43857-1978 "Main Size of Electromechanical Energy Meter", JISC1211 "Direct Access Energy Meter", JISC1216 "Electric Energy Meter Working with Transformers", etc. Appendix A of this guidance document is an informative annex. This guidance technical document was proposed by the China Machinery Industry Federation. This guiding technical document is under the jurisdiction of the National Electrotechnical Instrumentation Standardization Technical Committee. This guiding technical document drafting unit. Harbin Electric Instrument Research Institute, Huali Instrument Group Co., Ltd., State Grid Corporation, China Southern Power Grid Corporation, Hunan Power Company, Henan Power Company, Zhejiang Electric Power Test Institute, Gansu Electric Power Company, Fujian Provincial Electric Power Research Institute, Shanghai Electric Power Company Power Meter Measurement and Management Institute, Tianjin New Jusheng Electronics Co., Ltd., Zhejiang Zhengtai Instrument Table limited liability company, Hangzhou Hualong Electronic Technology Co., Ltd., Ningbo Samsung Technology Co., Ltd., Shenzhen Hao Ningda Power Meter Manufacturing Co., Ltd. Company, Cixi Sanchao Power Meter Factory, Harbin Electric Meter Instrument Factory Co., Ltd., Siping City Double Happiness Technology Co., Ltd. The main drafters of this guiding technical document. Wang Zhaohong, Chen Xiangqun, Zhong Zuan, Zhao Wei, Xu Heping, Wang Yanbo, Lin Dehao, Du Xingang, Lu Xingyuan, Li Xueyong, Liu Xing, Xu Maolin, Xia Yali, Liu Dexin, Su You, Xiao Xiaoqing, Xu Renheng, Liu Xiancheng, Li Xisheng. This guidance document is the first release. GB /Z21192-2007 Electric meter shape and installation size

1 Scope

This guidance document specifies the fixed installation dimensions and dimensions of the AC energy meter, as well as the main between the terminals and the terminals. size. This guidance document applies to the installation and use of wiring in a grid with a reference frequency of 50 Hz (60 Hz). AC energy meter. For the use of other wiring methods, refer to the use of this guidance.

2 Normative references

The terms of the following documents are incorporated into the terms of this guidance document by reference to this guidance. Any dated Reference documents, all subsequent amendments (not including errata content) or revisions do not apply to this guidance technical document, however, drums The parties that have reached an agreement under this guidance document will investigate whether the latest versions of these documents are available. Any undated reference The latest version of the document applies to this guidance document. GB/T 321 priority number and priority number system (GB/T 321-2005, ISO 3.1973, IDT) GB/T 15283 0.5, 1 and 2 AC active energy meters (GB/T 15283-1994, idt IEC 62051. 1988) GB/T 15284-2002 Special requirements for multi-rate electric energy meters GB/T 17215 Class 1 and Class 2 Static AC Active Energy Meter (GB/T 17215-2002IEC 61036.2000) GB/T 17215.211-2006 General requirements, test and test conditions for alternating current measuring equipment - Part 11 (IEC 62052-11.2003, IDT) GB/T 17882 Class 2 and Class 3 Static AC Reactive Energy Meter (GB/T 17882-1999, eqv IEC 61268.1995) GB/T 17883 0.2S class and 0.5S class static AC active energy meter (GB/T 17883-1999, eqv IEC 60687. 1992)

3 Terms and definitions

GB/T 17215.211-2006, GB/T 15283, GB/T 15284, GB/T 17215, GB/T 17882 established and the following Terms and definitions apply to this guidance document. 3.1 The maximum size that can be reached by the overall height (A), width (B), and thickness (C) of the energy meter. Note. These dimensions do not include the exposed hooks of the case and the extreme dimensions of the fixed climb. 3.2 The size used to fix the position of the energy meter.

4 requirements

4.1 Dimensions and fixed installation dimensions The meanings and identifiers of the specific dimensions are shown in Figure 1 and Table 1. GB /Z21192-2007
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GBZ21192-2007_English be delivered?

Answer: Upon your order, we will start to translate GBZ21192-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GBZ21192-2007_English with my colleagues?

Answer: Yes. The purchased PDF of GBZ21192-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.