Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 5023.1-2008 English PDF

US$374.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 5023.1-2008: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 1: General requirements
Status: Valid

GB/T 5023.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 5023.1-2008374 Add to Cart 3 days Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 1: General requirements Valid
GB 5023.1-1997719 Add to Cart 3 days Polyvinyl chloride insulated cables of rated voltages up to and including 450/750V. Part 1: General requirements Obsolete
GB 5023.1-1985RFQ ASK 3 days Polyvinyl chloride insulated cables (wires) of rated voltages up to and including 450/750V--General requirements Obsolete

Similar standards

GB/T 3956   GB/T 6995.1   GB/T 5013.1   GB/T 5023.5   GB/T 5023.7   GB/T 5023.4   

Basic data

Standard ID: GB/T 5023.1-2008 (GB/T5023.1-2008)
Description (Translated English): Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 1: General requirements
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: K13
Classification of International Standard: 29.060.20
Word Count Estimation: 19,190
Date of Issue: 2008-06-30
Date of Implementation: 2009-05-01
Older Standard (superseded by this standard): GB 5023.1-1997
Quoted Standard: GB/T 2951.11-2008; GB/T 2951.12-2008; GB/T 2951.14-2008; GB/T 2951.21-2008; GB/T 2951.31-2008; GB/T 2951.32-2008; GB/T 3956-1997; GB/T 5023.2-2008; GB/T 5023.3-2008; GB/T 5023.4-2008; GB/T 5023.5-2008; GB/T 18380.12-2008; IEC 173-1964; IEC 62440
Adopted Standard: IEC 60227-1-2007, IDT
Regulation (derived from): Announcement of Newly Approved National Standards No. 11 of 2008 (No. 124 overall)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard applies to the rated voltage U0/U is 450/750V and below PVC insulated and sheathed (if any) flexible cable and hard cable for AC 450/750V nominal voltage does not exceed the power unit. Note: For some models of flexible cable, you can use the term "soft line. " Various types of cables required in GB/T 5023. 3, GB/T 5023. 4 and other standards. Cable models that method, see Appendix A. In the GB/T 5023 1st, 3rd and 4th and some other test methods specified in GB/T 5023. 2, GB/T 18380. 12-2008 and GB/T 2951-2008 the relevant part.

GB/T 5023.1-2008: Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 1: General requirements


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V. Part 1. General requirements ICS 29.060.20 K13 National Standards of People's Republic of China GB/T 5023.1-2008/IEC 60227-1.2007 Replacing GB 5023.1-1997 Rated voltage 450/750 and below Vp PVC insulated cables Part 1. General requirements (IEC 60227-1.2007, IDT) Posted 2009-05-01 2008-06-30 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 5023 "rated voltage 450/750V and below PVC insulated cables" is divided into seven parts. --- Part 1. General requirements; --- Part 2. Test methods; --- Part 3. Non-sheathed cables for fixed wiring; --- Part 4. Sheathed cables for fixed wiring; --- Part 5. Flexible cables (cords); --- Part 6. Lift cables and cables for flexible connection; --- Part 7. two-core or multi-core shielded and unshielded cable. This section GB/T 5023 Part 1. This section identical with IEC 60227-1.2007 "rated voltage 450/750V and with Under PVC insulated cables - Part 1. General requirements "Version 3.0 (in English). For ease of use, GB/T 5023 made this part of the following editorial changes. "." --- With a decimal point instead of a comma as the decimal point, ""; --- Remove the IEC 60227-1.2007 Foreword; --- Increase the informative Appendix B. This Part replaces GB 5023.1-1997 "rated voltage 450/750V and below PVC insulated cables - Part 1. General requirements". This section of the main changes compared to GB 5023.1-1997 are as follows. --- 3.1.1 modify the continuity of signs; --- 4.1.1 removed the "any multi-core cable should not use red, gray, white" requirements, increasing the provision of note "are advised to avoid Red and white "; --- Removed 4.1.2 Notes "insulated core unsheathed core parallel cord without recognition" by modifying the three-core, four-core or five-core cable Chromatography; --- Note 4.1.3 of the blue to blue; --- Specified in Table 1 PVC/E of non-polluting aging test conditions were changed (100 ± 2) ℃, 10 × 24h; --- 5.5.1 increase 90 ℃ PVC sheathed mixture PVC/ST10, and increase PVC/ST10 full performance data in Table 2; --- Tables 1 and 2 in the first eight low temperature impact test, according to the country's climatic conditions, the test temperature was -15 ℃, can also be Test temperature adjusted according to customer requirements; --- Appendix A added 56, 57 and 71c cable type. a) 56 --- conductor temperature of 90 ℃ heat-resistant light PVC sheathed flexible cord (60227IEC 56); b) 57 --- conductor temperature of 90 ℃ heat-resistant ordinary PVC sheathed flexible cord (60227IEC 57); c) 71c --- Round PVC sheathed lift cables and cables for flexible connection (60227IEC 71c). Appendix A of this section is normative appendix, Appendix B is an informative annex. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Baosheng Science and Technology Innovation Co., Ltd., the cable factory in Changshu, Jiangsu on the cable Group Co., Ltd., Far East Cable Factory, Tianjin Jinshan Electric Wire & Cable Co., Ltd., Zhejiang Wanma Cable Co., Ltd. GB/T 5023.1-2008/IEC 60227-1.2007 The main drafters of this section. Yan Yongchang, the right to housing health, money Guofeng, Li Bin, Wang Chuanbin, Zheng Guojun, Zheng. This part of the standard replaces the previous editions are. --- GB 5023.1-1985, GB 5023.1-1997. GB/T 5023.1-2008/IEC 60227-1.2007 Rated voltage 450/750 and below Vp PVC insulated cables Part 1. General requirements

1 General

1.1 Scope GB/T 5023 This section applies to the rated voltage U0/U is 450/750V and below PVC insulated and sheathed (if any) of soft power Cable and hard cable for AC voltage does not exceed the nominal power unit 450/750V is. NOTE. For some types of flexible cables, you can use the term "cord." Various types of cable specified in GB/T 5023.3, GB/T 5023.4 and other standards. How to order cables in Appendix A. Test methods specified in GB/T 1st, 3rd and 4th 5023 in other parts see GB/T 5023.2, GB/T 18380.12- Relevant parts of 2008 and GB/T 2951-2008 of. 1.2 Normative references The following documents contain provisions which, through GB/T reference in this 5023 constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section. GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1.2001, IDT) GB/T 2951.12-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 12. General test side Law --- Thermal aging methods (IEC 60811-1-2. 1985, IDT) GB/T 2951.14-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 14. General test side Law --- Low temperature test (IEC 60811-1-4. 1985, IDT) GB/T 2951.21-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 21. elastomeric compounds designed Test method for ozone resistance test --- --- --- Hot set test - Mineral oil immersion tests (IEC 60811-2-1.2001, IDT) GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture Methods specific high temperature pressure test --- --- resistance to cracking (IEC 60811-3-1. 1985, IDT) GB/T 2951.32-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 32. Polyvinyl chloride mixture Special test methods --- --- Loss of mass test - Thermal stability test (IEC 60811-3-2. 1985, IDT) GB/T 3956-1997 cable conductor (idt IEC 60228. 1978) GB/T 5023.2-2008 rated voltage of 450/750V or less PVC insulation - Part 2. Test methods (IEC 60227-2.2003, IDT) GB/T 5023.3-2008 rated voltage of 450/750V and below PVC insulated cables - Part 3. No fixed wiring Sheathed cables (IEC 60227-3.1997, IDT) GB/T 5023.4-2008 rated voltage of 450/750V and below PVC insulated cables Part 4. Fixed wiring protection Cables (IEC 60227-4.1997, IDT) GB/T 5023.5-2008 rated voltage of 450/750V and below PVC insulated cables Part 5. Flexible cables (cords) (IEC 60227-5.2003, IDT) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire GB/T 5023.1-2008/IEC 60227-1.2007
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 5023.1-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 5023.1-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 5023.1-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 5023.1-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 5023.1-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 5023.1-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.