Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

GB/T 4618.1-2008 English PDF

US$154.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
GB/T 4618.1-2008: Plastics -- Epoxy resins -- Determination of chlorine content -- Part 1: Inorganic chlorine
Status: Valid

GB/T 4618.1: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
GB/T 4618.1-2008154 Add to Cart 3 days Plastics -- Epoxy resins -- Determination of chlorine content -- Part 1: Inorganic chlorine Valid
GB/T 4618-1984199 Add to Cart 2 days Epoxide resins and related materials--Determination of easily saponifiable chlorine Obsolete

Similar standards

GB/T 5761   GB/T 4615   GB/T 6343   GB/T 4611   GB/T 4612   GB/T 4618.2   

Basic data

Standard ID: GB/T 4618.1-2008 (GB/T4618.1-2008)
Description (Translated English): Plastics -- Epoxy resins -- Determination of chlorine content -- Part 1: Inorganic chlorine
Sector / Industry: National Standard (Recommended)
Classification of Chinese Standard: G32
Classification of International Standard: 83.080.10
Word Count Estimation: 8,883
Date of Issue: 2008-09-04
Date of Implementation: 2009-04-01
Older Standard (superseded by this standard): GB/T 4613-1984
Adopted Standard: ISO 21627-1-2002, IDT
Regulation (derived from): National Standard Approval Announcement 2008 No.14 (Total No.127)
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China
Summary: This standard specifies the use of potentiometric titrator direct determination of inorganic chlorine epoxy resin (chloride ion) approach. Inorganic chlorine content in the epoxy resin represented by the number per kilogram mg.

GB/T 4618.1-2008: Plastics -- Epoxy resins -- Determination of chlorine content -- Part 1: Inorganic chlorine


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Plastics Epoxy resins Determination of chlorine content Part 1.. Inorganic chlorine ICS 83.080.10 G32 National Standards of People's Republic of China GB/T 4618.1-2008/ISO 21627-1.2002 Replacing GB/T 4613-1984 Plastics - Determination of chlorine content epoxy resin Part 1. Inorganic chlorine (ISO 21627-1.2002, IDT) Posted 2008-09-04 2009-04-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released

Foreword

GB/T 4618 "Plastics - Determination of chlorine content epoxy resin" is divided into three parts. --- Part 1. Inorganic chlorine; --- Part 2. Easily saponifiable chlorine; --- Part 3. Total chlorine. This section GB/T 4618 Part 1, identical with ISO 21627-1.2002 "Plastics --- --- chlorine content of an epoxy resin Determination --- Part 1. Inorganic chlorine "(in English). This section is equivalent translation ISO 21627-1.2002, identical in technical content. For ease of use, this section do the following Edit modifications. a) The "ISO 21627.2002 in this part" to "GB/T 4618 this part" or "this part"; b) Delete the ISO 21627-1.2002 Foreword; c) increase the foreword to the national standard of this Part; d) For ISO 21627-1.2002 and other international standards referenced in our country is equivalent to using the standard, this section with a quote me National Standards corresponding to international standards in place, the rest is not tantamount to the adoption of a standard international standards in this section are Referred to directly; e) use of decimal notation. "" instead of the international standard decimal symbol "." f) the precision of the relevant Chapter 9 content into information appendix NA "ISO 21627-1.2002 precision" in. This Part replaces GB/T 4613-1984 "resins and glycidyl esters - Determination of inorganic chlorine." Section compared with GB/T 4613-1984 The main changes are as follows. --- Change the standard name, increasing the foreword; --- Increasing the normative references; --- Increasing the terms and definitions; --- Reagent butanone replaced by acetone; --- Standard solution 0.002mol/L 0.01N silver nitrate solution consisting of isopropyl alcohol or an aqueous solution of silver nitrate into 0.002N; --- Reference reagent sodium sulfate into a temperature from 120 ℃ 500 ℃ ~ 600 ℃; --- Sample weight change by the 3g ~ 10g 10g; --- Increase the finish explaining the determination; --- Increased requirements result of rounding. Appendix NA This section is informative appendix. This part is proposed by the China Petroleum and Chemical Industry Association. This part of the National Plastics Standardization Technical Committee (SAC/TC15) centralized. This section is responsible for drafting. National Quality Supervision and Inspection Center of synthetic resin. Participated in the drafting of this section. Bluestar New Chemical Materials Co., Ltd. Wuxi Resin Factory, Anhui Hengyuan Chemical Co., Ltd. The main drafters of this section. Wangyong Gui, Wang Yan, Feng Xuefeng, Cheng Zhen Shuo. This part of the standard replaces the previous editions are. --- GB/T 4613-1984. GB/T 4618.1-2008/ISO 21627-1.2002 Plastics - Determination of chlorine content epoxy resin Part 1. Inorganic chlorine Warning --- using GB/T 4618 in this part of the staff should be familiar with general laboratory rules. This part not covered with the use of Union Any security issues system. Responsibility of the user to establish appropriate safety and health measures and compliance with relevant regulations.

1 Scope

GB/T 4618 provisions of this part of the use of epoxy resin titrator direct determination of inorganic chlorine (chlorine ion) method. Inorganic chlorine content expressed in kilograms per milligram epoxy.

2 Normative references

The following documents contain provisions which, through reference to GB/T 4618 to the present, constitute provisions of this section. For dated references, All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encourage an agreement under this section Parties to study the latest versions of these documents. For undated reference documents, the latest versions apply to this section. ISO 3696. 1987 specifications and test methods of laboratory water analysis ISO 5725-2.1994 Accuracy of measurement methods and results (trueness and precision) --- Part 2. Determine the standard measurement method Repeatability and reproducibility of the basic method

3 Terms and Definitions

The following terms and definitions apply GB/T 4618 of this section. 3.1 It is present in the resin in the Cl-, also known as chlorine ions. Principle 4 Sample is dissolved in a suitable solvent, for example, potentiometric titration with standard silver nitrate solution to determine the inorganic chlorine.

5 Reagents

Except as otherwise provided in this section, the purity of the reagents used should be more analytical, test water shall comply with ISO 3696. 1987 in three or Above water specifications. 5.1 acetone Note. In some cases, may not dissolve the resin in acetone. In this case, butanone (methyl ethyl ketone) or THF (tetrahydrofuran) or other suitable solvent Agent, and described in the test report. 5.2 isopropanol 5.3 glacial acetic acid 5.4 isopropanol solution of silver nitrate. 0.002mol/L. 5.4.1 preparation 17g of silver nitrate was dissolved in water and diluted to 1L (0.1mol/L). Take 0.1mol/L aqueous solution of silver nitrate into 20mL 1L volumetric flask, dilute to the mark with isopropanol (5.2). 5.4.2 Calibration Previously weighed in the dry base 500 ℃ ~ 600 ℃ sodium chloride 115mg ~ 120mg, accurate to 0.1mg, dissolved in 1L of water. GB/T 4618.1-2008/ISO 21627-1.2002
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of GB/T 4618.1-2008_English be delivered?

Answer: Upon your order, we will start to translate GB/T 4618.1-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of GB/T 4618.1-2008_English with my colleagues?

Answer: Yes. The purchased PDF of GB/T 4618.1-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version GB/T 4618.1-2008?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 4618.1-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.