GB/T 3930-2008 English PDFUS$274.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 3930-2008: D.C. bridge for measuring resistance Status: Valid GB/T 3930: Historical versions
Basic dataStandard ID: GB/T 3930-2008 (GB/T3930-2008)Description (Translated English): D.C. bridge for measuring resistance Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: N25 Classification of International Standard: 17.220.20 Word Count Estimation: 14,113 Date of Issue: 2008-08-19 Date of Implementation: 2009-03-01 Older Standard (superseded by this standard): GB/T 3930-1983 Adopted Standard: IEC 60564-1997, IDT Regulation (derived from): Announcement of Newly Approved National Standards No. 14 of 2008 (total 127) Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China Summary: This standard applies to DC bridges for measuring resistance, but also for the bridge included auxiliary equipment. This standard does not apply to the bridge comparator, auto balancing bridge as well as those by means of zero-meter scale to get some indication of the bridge, and the bridge is not suitable for use with an external auxiliary equipment. GB/T 3930-2008: D.C. bridge for measuring resistance---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.DCbridge for measuring resistance ICS 17.220.20 N25 National Standards of People's Republic of China GB/T 3930-2008/IEC 60564.1997 Replacing GB/T 3930-1983 Measure the resistance with a DC bridge (IEC 60564.1997, IDT) Posted 2008-08-19 2009-03-01 implementation Administration of Quality Supervision, Inspection and Quarantine of People's Republic of China Standardization Administration of China released ForewordThis standard is equivalent to using the International Electrotechnical Commission standard IEC 60564.1997 "by DC resistance measurement bridge" (in English), and its technology inside Content and structure of IEC 60564.1997 are identical. This standard is in place from the date of implementation of the GB/T 3930-1983 "by measuring resistance DC bridge." This standard compared with GB/T 3930-1983, the main changes are as follows. --- 8.2 standard minimum insulation resistance shall not be less than the original 5MΩ, to be not less than 20MΩ. --- Information and content of the flag, the deletion of the original test voltage flag, flag increases the level of pollution and other requirements. The standard proposed by China Machinery Industry Federation. This standard by the National Electrical Instrument Standardization Technical Committee (SAC/TC104) centralized. This standard is drafted by. Shanghai Instrument Research Institute. Participated in the drafting of this standard. Shanghai Factory Zhengyang, the Highland Sting Instrument Research Institute. The main drafters of this standard. Zhangyin Fu, Dong Yafeng, Sun Xiaohong. This standard replaces the standards previously issued as follows. --- GB/T 3930-1983. GB/T 3930-2008/IEC 60564.1997 Measure the resistance with a DC bridge1 ScopeThis standard applies to the measurement of DC resistance bridge use, also applies to the ancillary equipment included bridge. This standard does not apply to bridge the comparator 1), as well as those self-balancing bridge instrument scale to zero by means partial indication of the bridge, nor Suitable for external auxiliary equipment and use of the bridge together. 1) The comparator bridge resistors is used to compare two means, for example. the ratio of the set of two adjustable arms.2 Terms and definitionsThe following terms and definitions apply to this standard. 2.1 Assembly comprising at least three arms of the resistance, plus test resistors, constitute a network bridge, the bridge will also be required to work a DC And a power supply means zero instrument, which can be included or may not be included. When a balance exists between the resistors in a bridge computable relationship. Note. The DC resistance measurement bridge can be used for measuring the leakage current with or without shielding (line) of the double-ended or four-terminal resistor, accordingly it said Having or not having a leakage current shield (line) of the double-ended type four-terminal bridge or bridge. 2.2 Test resistor. 2.3 Only one current potential used along with a side button resistor at each end. 2.4 Two side buttons at each end of the resistor, which is used to access a current-carrying loop, another for connecting potential measurement circuit. Note. Let no current flows from the potential end of the button, the resistance value is defined as the ratio of potential difference between the current flowing through the end of the current button button between two potential side. 2.5 Having a connection to the isolated side button (usually called "protective side button") leakage current shield (line) resistor. Note. The leakage current shield (line) resistors available △ a network of connected between each pair of side buttons of the three equivalent resistors to represent the three resistor The resistance in the two main side button is to be measured between primary equivalent resistance. △ network other two resistors is usually insulation (leakage) resistance, Very high resistance to primary equivalent resistance, their resistance can be primary equivalent resistance than the same order of magnitude or less. Main equivalent resistance can be seen as two End resistors, or as one four-terminal resistor. 2.6 A multi-value resistor, it is usually by a conversion device will match the step value increment resistor value selection combinations. Each step value Incremental decimal equivalent of a resistance, for example, 0.1Ω, 1Ω or 10Ω. Note. a decade resistor is typically 10, 11 or 12 selectable resistance values \u200b\u200b(including zero). GB/T 3930-2008/IEC 60564.1997 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 3930-2008_English be delivered?Answer: Upon your order, we will start to translate GB/T 3930-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 3930-2008_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 3930-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version GB/T 3930-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version GB/T 3930-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |