GB/T 37186-2018 English PDFUS$199.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. GB/T 37186-2018: Gas analysis -- Determination of sulfur dioxide and nitrogen oxides -- Ultraviolet differential optical absorption spectroscopy Status: Valid
Basic dataStandard ID: GB/T 37186-2018 (GB/T37186-2018)Description (Translated English): Gas analysis -- Determination of sulfur dioxide and nitrogen oxides -- Ultraviolet differential optical absorption spectroscopy Sector / Industry: National Standard (Recommended) Classification of Chinese Standard: G86 Classification of International Standard: 71.040.40 Word Count Estimation: 10,146 Date of Issue: 2018-12-28 Date of Implementation: 2019-11-01 Issuing agency(ies): State Administration for Market Regulation, China National Standardization Administration GB/T 37186-2018: Gas analysis -- Determination of sulfur dioxide and nitrogen oxides -- Ultraviolet differential optical absorption spectroscopy---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Gas analysis--Determination of sulfur dioxide and nitrogen oxides--Ultraviolet differential optical absorption spectroscopy ICS 71.040.40 G86 National Standards of People's Republic of China Gas analysis for determination of sulfur dioxide and nitrogen oxides Ultraviolet differential absorption spectroscopy Published on.2018-12-28 2019-11-01 implementation State market supervision and administration China National Standardization Administration issued ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the China Petroleum and Chemical Industry Federation. This standard is under the jurisdiction of the National Gas Standardization Technical Committee Gas Analysis Subcommittee (SAC/TC206/SC1). This standard was drafted. Xi'an Dingyan Technology Co., Ltd., Institute of Chemistry, China Institute of Testing Technology, Southwest Chemical Research Jiyuan Co., Ltd., Xinjiang Environmental Protection Science Research Institute, Sichuan Zhongjian Standards Technology Co., Ltd., Shaanxi Provincial Environmental Monitoring Center Station, Shaanxi Province Institute of Metrology, Chengdu Environmental Monitoring Center, Chengdu Environmental Protection Research Institute, Sichuan University, Concentration Technology (Hangzhou) Co., Ltd., Qingdao Laoshan Institute of Applied Technology. The main drafters of this standard. Wang Weikang, Yu Haiyang, Shi Zhaoqi, Zhou Pengyun, Chen Yali, Zhou Xin, Yuan Xinjie, Li Zhiang, Huang Shenmin, Ren Hongping, Gao Xuhui, Xing Lili, Tao Hongqun, Xie Xiang, Wang Yating, Ji Xuemei, Li Chenghui, Tian Yunfei, Lu Jieling, Huang Yangyu. Gas analysis for determination of sulfur dioxide and nitrogen oxides Ultraviolet differential absorption spectroscopy1 ScopeThis standard specifies methods for the determination of sulfur dioxide and nitrogen oxides in gases using ultraviolet differential absorption spectroscopy. This standard applies to the determination of sulfur dioxide and nitrogen oxides in gases such as standard gases, industrial gases and ambient air. Sulfur dioxide determination The range is from 0.2mg/m3 to 5000mg/m3, and the nitric oxide measurement range is from 0.3mg/m3 to 5000mg/m3. The circumference is 2mg/m3~5000mg/m3.2 Normative referencesThe following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 3723 General rules for sampling safety of industrial chemical products GB/T 5274.1 Preparation of mixed gases for gas analysis - Part 1 GB/T 14850 Gas Analysis Vocabulary GB/T 33360 Gas Analysis Technical Guide for Gas Purification of Trace Analysis Technical requirements and testing methods for HJ76 fixed pollution source flue gas (SO2, NOx, particulate matter) continuous monitoring system JJF1059.1 Measurement Uncertainty Evaluation and Representation3 Terms and definitionsThe following terms and definitions as defined in GB/T 14850 apply to this document. 3.1 Nitrogen oxides An oxide of nitrogen in the form of nitrogen monoxide and nitrogen dioxide in a gas.4 PrincipleThe sulfur dioxide and nitrogen oxides in the gas sample have a characteristic absorption spectrum in the ultraviolet region, and the ultraviolet light is sucked by the gas to be tested through the gas chamber. The absorbed ultraviolet light enters the spectrometer. By processing the spectral information, the fast-changing part of the spectrum is separated and inverted Calculated to obtain the content of sulfur dioxide and nitrogen oxides in the gas to be tested. See Appendix A for the specific working principle.5 Instrument requirements5.1 Select the measuring instrument within the measuring range according to the sulfur dioxide and nitrogen oxide content to be tested. 5.2 The detection limit of the instrument should meet the requirements of sulfur dioxide and nitrogen oxides to be tested. 5.3 Within the measuring range of the instrument, there should be a definite functional relationship between the response of the instrument and the content of sulphur dioxide and nitrogen oxides. 5.4 The instrument shall be qualified by metrological verification and within the validity period of the verification. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of GB/T 37186-2018_English be delivered?Answer: Upon your order, we will start to translate GB/T 37186-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of GB/T 37186-2018_English with my colleagues?Answer: Yes. The purchased PDF of GB/T 37186-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |